48
Operating Instructions for Temperature Measurement
Measurement using active electrodes RF-T 28, RF-T 31 and RF-T 32
Set selector switch (3) (UNI 1) or (4) (UNI 2) to position »200 °C«.
Connect electrode to meter socket (1) (UNI 1) or (2) (UNI 2).
Press measuring key (4) (UNI 1) or (5) (UNI 2) and read off result in °C displayed by the LCD
readout (2) (UNI 1) or (3) (UNI 2).
Measurement using PT 100 temperature probes
Set selector switch (3) (UNI 1) or (4) (UNI 2) to position »200 °C« or »600 °C«.
Connect temperature probe to meter socket (1) (UNI 1) or (2) (UNI 2).
Press measuring key (4) (UNI 1) or (5) (UNI 2) and read off result in °C displayed by the LCD
readout (2) (UNI 1) or (3) (UNI 2).
Measurement using active electrode IR 40
Set selector switch (3) (UNI 1) or (4) (UNI 2) to position »M«.
Connect infrared temperature probe to the meter socket (1) (UNI 1) or (2) (UNI 2).
Adjust temperature probe to the desired measuring spot and press measuring key (4) (UNI 1) or
(5) (UNI 2). Read off result in °C.