Operating Manual for TC-KS Series of Electronic waterproof plattformscales
( For following models:
TC60KSB,TC150KSB,TC300KSB
)
1.
Overview
Thanks for your support of our product, with waterproof and anti-pollution functions,
TC-KS series of electronic waterproof plattformscales can be used in variety of weighing
measurement.With all stainless steel body,it can fit for a variety of harsh environment.
2. Specification and performance index
Model
TC60KSB
TC150KSB
TC300KSB
Weighing(max.)
60kg
150kg
300kg
Resolution
20g
50g
100g
Calibration value
5d
5d
5d
Tare range
0~60kg
0~150kg
0~300kg
Calibration weight
50kg
100kg
200kg
Weighing plate
500×400 mm
Power supply
power adapter input:AC230V50Hz/60Hz Output: DC12V/600 mA
Battery: 6V 4AH (include)
Operation
temperature
-10~40
℃
Humidity
≤98%R.H
3.Preparatory work and attentions
3.1
The scale should be placed on the flat and solid surface. Adjust the four legs
and let them support the scale.
3.2
The scale should avoid great temperature changing, intense air flowing and
ground vibration.
3.3
Use separate power outlet and avoid dynamic power.
3.4
Without any item when switching on the power.
3.5
15min. preheating is needed.
3.6
When the indicator of battery lights, which means battery is near empty and
need to recharge. Using balance under this situation can result in instability or
major error. At the same time, the calibration function will automatically shut
down.
3.7
Because of long-term not using, the scale must be placed in dry-ventilated
place and recharge every three months. Charging is necessary before or
during re-using.
3.8
Carefully weight. Any impact or overload is interdicted. Otherwise the scale
will be permanent damaged.