Technical data
73
· G&D VisionXS-F-DP-UHR
Features of transmission modules
MULTIMODE TRANSMISSION MODULE
Data transmission
Type:
fibre optics (2 glass fibres)
Interface type:
LC duplex
Cable length (max.)
Multimode 50/125
μ
m,
Class OM4:
400 metres (fibres with 4700MHz*km)
Multimode 50/125
μ
m,
Class OM3:
400 metres (fibres with 2000MHz*km)
Multimode 50/125
μ
m,
Class OM2:
200 metres (fibres with 500MHz*km)
Multimode 50/125
μ
m:
150 metres (fibres with 400MHz*km)
Multimode 62,5/125
μ
m,
Class OM1:
100 metres (fibres with 200MHz*km)
Multimode 62,5/125
μ
m,
FDDI grade:
70 metres (fibres with 160MHz*km)
SINGLEMODE(S) TRANSMISSION MODULE
Data transmission
Type:
fibre optics (2 glass fibres)
Interface type:
LC duplex
Cable length (max.)
Singlemode 9/125
μ
m,
Class OS1:
5 kilometres
SINGLEMODE(S+) TRANSMISSION MODULE
Data transmission
Type:
fibre optics (2 glass fibres)
Interface type:
LC duplex
Cable length (max.)
Singlemode 9/125
μ
m,
Class OS1:
10 kilometres