16

TROUBLESHOOTING  TIPS

CARE & CLEANING

With time and use, the clamping surfaces of your machine may become oily or dirty and result 
in string or clamp slippage while stringing. Periodic cleaning of the String Clamps, String Clamp 
Base and String Gripper is recommended. Knife sharpening stones work well for cleaning the 
diamond coated string clamping surfaces. Cleaning with a solvent such as isopropyl alcohol 
and a mild abrasive tool such as a toothbrush also works well to remove oily or greasy build up.

PROBLEM

SOLUTION

String slips in clamps

- Adjust gap between clamp jaws
- Clean clamp jaws

String slips in gripper

- Clean gripper jaws
- Make sure string is wrapped over top gripper 

prior to inserting between gripper jaws

String clamp base slips on turntable

- Clean bottom of clamp & top of turntable with 

alcohol

- Adjust clamp base locking nut

Electrical system does not function

- Check power source
- Check power cord connections

String tension too tight or too loose

- Check tension using a tension calibrator, 

adjust machine calibration if necessary

5

POWER  CONNECTION & CONTROLS

Front Panel Features

A -  String Gripper
B -  Tension Switch
C -  LED Tension Display

Back Panel Features

A - 

Lighted Power Switch

B - 

Foot Pedal Switch Receptacle

C - 

A/C Power Cord Socket

D - 

String Length Meter (currently not 

 available)

B

C

A

C

B

A

Instructions for Power Connection and Controls

CAUTION ! Before connecting to the power supply, check the voltage source that the 
machine is being connected to.

 

The acceptable range of input voltages for this ma-

chine is between 100 V and 240 V @ 50 to 60 Hz. If you have any questions regarding 
the input voltage supply for your area, please ask your electric utility company.

To install the power cord, insert the female end of the power cord into the AC Adapter and 
then insert the female end of the cord from the AC Adapter into the A/C Power Cord Socket 
“C” located on the back panel of the tensioner.  Plug the male end of the power cord into a 
grounded power outlet. When using extension cords, use grounded heavy duty extension 
cords rated for 15 AMP service. 

To connect the foot pedal switch, insert the male pin at the end of the foot pedal switch cord 
into the Foot Pedal Switch Receptacle “B” located on the back panel of the tensioner.

Switch on the machine by pressing the Lighted On-Off Power Switch on the back panel. At 
start-up, the LED will display a countdown from “9.0” to “0.0” while the machine performs a 
self diagnostics check at start-up. 

D

WARNING!  

FOR INDOOR USE ONLY.  

NEVER OPEN UNIT WITH POWER CONNECTED.  

CHILDREN SHOULD NEVER BE PERMITTED TO OPER-

ATE THIS MACHINE WITHOUT ADULT SUPERVISION.

Summary of Contents for Els

Page 1: ...e Pittsburgh Pennsylvania 15222 Phone 800 333 0337 Fax 412 323 0317 Visit our website at www gammasports com Copyright 2012 GAMMA Sports All Rights Reserved MMAN 30 MPELS 12 OWNER S MANUAL Issue 3 Nov...

Page 2: ...res listed on page 17 GAMMA s obligation under this warranty is limited to repair or replacement of defective EQUIPMENT and no one is authorized to promise any other liability GAMMA shall in no event...

Page 3: ...3 UNIV DC STRING CLAMP MRSGD DIE CAST GRIPPER MQAC12 QA BASE CLAMP 71 6MM T HANDLE HEX WRENCH 109 NEEDLE NOSE PLIERS 110 BENT NOSE PLIERS 167 HEX WRENCH SET 171 DIAGONAL CUTTERS 196 17MM SOCKET E16 A...

Page 4: ...be may also be cleaned with isopropyl alcohol After this type of thorough cleaning the post andtubeshouldbetreatedwithalightcoating of machine oil to protect the surfaces against corrosion and to ensu...

Page 5: ...edal Switch Receptacle C A C Power Cord Socket D String Length Meter currently not available B C A C B A Instructions for Power Connection and Controls CAUTION Before connecting to the power supply ch...

Page 6: ...ents Test Button Racquet Strung Press once for approximate number of racquets strung Press again to return Press and hold for 5 seconds and the machine does an internal diagnostic check such as the on...

Page 7: ...en any key or button is pressed or when there is a problem with some function of the machine The buzzer can be disabled if desired for normal keypad entries To disable the buzzer turn the machine on a...

Page 8: ...t so that the pads contact the frame squarely when the arms are closed against the racquet Should the shoulder supports block string holes adjust the frame support slides to re position the racquet be...

Page 9: ...he clamped position and back generally requires the rotation permitted by the slot in the clamp base String Clamp Operation The string clamps are a dual action design wherethestringclampandclampbaseop...

Page 10: ...llic strings will generally string up tighter on the machine compared to synthetic or natural gut strings Therefore when stringing with Aramid Kevlar Technora hybrid strings or metallic strings we rec...

Reviews: