background image

8

SAVE THESE INSTRUCTIONS

5.  INITIAL OPERATION

Once the solar heater has been assembled and the hoses are connected to the filter pump and pool return, unblock the flow of water 

into the pool return hose and turn on the pump and filter system. Bubbles will shoot out of the return nozzle into the pool initially 

while air is pushed out of the solar heater. If this persists for longer than 2 or 3 minutes, check for and repair any leaks in the hoses  

or connections. 

FOR BEST RESULTS: To reduce heat loss, use a pool cover on your pool overnight, run your filter system during daylight hours 

and cover the solar heater at night (if running the system).

6. MAINTENANCE

The solar heater should not require servicing or maintenance other than winterizing. Prior to the first frost, or at the end of your swim 

season, the solar heater should be removed from its connections to the pool and stored in a frost free location.

Winterizing

Drain all the water from the solar heater by disconnecting the tubes. Store in a location protected from frost. Reconnect the pool return 

tubes with a 1

½

”-1

½

” coupler (not included) or any properly sized 2-way valve if continued pool use is desired.

CAUTION: DO NOT ALLOW STANDING WATER INSIDE THE SOLAR HEATER TO FREEZE. WATER EXPANDS AS IT FREEZES AND 

CAN RUPTURE THE SOLAR COILS ON THE HEATER. 

7. TROUBLESHOOTING

Problem

Possibilities/Solutions

Does not appear to be heating the 

pool.

•  Check to make sure that water is flowing through the holes. Check the flow strength at the 

pool inlet.

•  Has it been sunny?
•  Put your pool cover on at night to prevent heat loss.
•  Additional heaters may be necessary.
• If using a bypass kit, check and adjust flow restrictions if necessary.

No initial bubbling after heater is  

connected and pump is on.

•  Check the setting of the filter to make sure it is returning water to the pool through the 

pool water inlet.

•  Check flow rate.

Bubbles continue  

to flow out of the pool water inlet well 

after the pump has been turned on.

•  Check the connections for a suction leak. 
•  Check to make sure the flow rate is normal.
•  There could be a break in the tubing.
•  There could be a clog in the tubing, try to purge out  

the clog.

Leaking heater

•  Check the connector seals and replace or repair if defective.

High filter pressure

•  Flow through heather may be too high. A bypass kit may be needed.
•  Filter may need backwashing or filter media change.
•  Pool/spa system valves may need adjusting.
•  Water return outlet may be blocked.

Summary of Contents for SolarPRO 4721

Page 1: ...ing parts call Customer Service toll free 1 888 339 2546 press 135 at any time Monday through Friday 8 00 am to 5 00 pm MST Please visit our website www game group com for potential updates to these i...

Page 2: ...pecialty retailer Contact GAME to receive a list of retail sources in your area If you wish further information regarding the installation of multiple heaters please contact GAME Customer Service 1 88...

Page 3: ...UCT FAILURE TO FOLLOW INSTRUCTIONS CAN CAUSE SEVERE AND OR FATAL INJURY IMPORTANT DO NOT RETURN PRODUCT TO STORE For technical assistance and missing parts call Customer Service toll free 1 888 339 25...

Page 4: ...ly set up and filled with water 2 your above ground pool is equipped with a pump operated water filtering system and 3 you have the necessary hoses needed to feed water in and out of your pool and fil...

Page 5: ...ater must come after the filter to prevent buildup in the tubing IMPORTANT If you are using a chlorine generator OR an in line chlorinator it must be connected in line following the solar heater to pr...

Page 6: ...t 10 feet away from pool 2 Heater Filter Pump Connection a Turn off filter pump b Block water flow at both the pool return inlet and the filter pump outlet to prevent water from flowing through the ho...

Page 7: ...re too wide to fit the hose connector usevtt the 1 1 tube reducer on the hose connector and continue CAUTION ENSURE ALL HOSE CONNECTIONS ARE TIGHT AND THE HOSES ARE NOT KINKED OR BENT AT SEVERE ANGLES...

Page 8: ...d 2 way valve if continued pool use is desired CAUTION DO NOT ALLOW STANDING WATER INSIDE THE SOLAR HEATER TO FREEZE WATER EXPANDS AS IT FREEZES AND CAN RUPTURE THE SOLAR COILS ON THE HEATER 7 TROUBLE...

Page 9: ...Liability EXCEPT FOR THE LIMITED WARRANTY DESCRIBED ABOVE IN NO EVENT WILL GAME HAVE ANY LIABILITY OF ANY KIND WHATSOEVER WHETHER UNDER CONTRACT TORT OR ANY OTHER THEORY OF LEGAL LIABILITY TO ANY PER...

Page 10: ...er with O Ring 2 7 Filter Hose 2 8 Adapter with O Ring for INTEX Pools 2 OR Adapter with O Ring for BESTWAY Pools 2 Note Some parts may be pre installed at the factory Parts not shown to scale MainUni...

Page 11: ...11 SAVE THESE INSTRUCTIONS...

Page 12: ...chnical assistance and missing parts call Customer Service toll free 1 888 339 2546 press 135 at any time Monday through Friday 8 00 am to 5 00 pm MST Please visit our website www game group com for p...

Page 13: ...GreatAmericanMerchandise Events 16444N 91stStreet Scottsdale AZ85260 1567U S A T l 888 382 5988 602 957 3825 T l copieur 602 957 7665 Courriel products game group com www game group com IMPORTANT NE R...

Reviews: