9
HOW TO USE
3.7 - Air quality indicator
The air quality is displayed by the LED
ring as outlined above, and shown
numerically in the display in µg/m
3
.
3.8 - Light sensor
In automatic mode, if ambient light falls
below 3 lumens for more than 3 minutes,
Rediair will enter night mode. If light levels
then exceed 3 lumens for 5 minutes, Rediair
will switch back to automatic mode.
LED AIR QUALIT Y INDICATOR DISPL AYS (3.7)
PM2.5 VALUE
(µg/m
3
) 1 - 35
36 - 75
76 - 150
151 - 500
AIR QUALIT Y
Very good
Good
Not good
Bad
DISPL AY COLOUR
Blue
Green
Amber
Red
3.6 - Filter indicator
The Rediair filter indicator displays the
status of the main filters. After 3000
hours of operation, this indicator will
light up continuously red, prompting
you to replace the main filters. If the
filter indicator flashes red intermittently,
it is time to clean the pre-filters.
• 3.6.1 - Working time display
: Press the
filter indicator button to view working
time of the current filters on the main
display (3.6). As the Rediair display has
only 3 digits, values of 1000 hours or more
will scroll across the screen. For example,
below shows a working time of 2349 hours.
• 3.6.2 - Resetting the filter time
: To
reset the timer after changing the
filters, press and hold the filter indicator
for 3 seconds. Both the filter indicator
and the working time will reset.
The light sensor is only active in
automatic mode. If night mode
is selected manually, using the
‘Mode Selection’ button (3.3),
Rediair will remain in night mode
regardless of the ambient light.
NOTE
µg/m
3
PM2.5
1h 2h 4h 8h 12h
AUTO
LOCK
POWER
MODE
SPEED
µg/m
3
PM2.5
1h 2h 4h 8h 12h
AUTO
FILTER
TIMER
LOCK
SPEED
WORKING TIME DISPL AY (3.6.1): 2349 HOURS