Programming Instructions

Each transmitter has its own unique internal address along with the data as to which button is pressed and transmitted. 
The receiver needs to be programmed to respond only to the specific transmitter it is intended to operate with. The 
following steps configure the receiver to operate with a particular transmitter. Up to 30 transmitters can be programmed 
to one receiver. Please read the entire programming procedure before starting. Make sure the receiver is connected to 
power before programming. When the receiver enters program mode, all previous transmitter addresses that were 
programmed will be erased from the receiver's memory.

1. Locate the pushbutton labeled "PROGRAM" on the receiver. Press and hold this button until the red LED next to the 
program button illuminates (approximately 3 seconds). The receiver is now in the transmitter program mode. Release 
the button. At this point all previously programmed transmitter addresses are erased from the receiver's memory.

2. Press and release any button on the transmitter and verify that the red program LED extinguishes and then 
illuminates (blinks once). 

3. Repeat previous step for additional transmitters that will operate with this particular receiver. The red LED on the 
receiver will extinguish and illuminate (blink) each time a transmitter is programmed. 

6. The receiver will return to normal mode if no transmitter buttons are pressed for 5-seconds. The red LED on the 
receiver will blink rapidly, then extinguish. The receiver is now in the normal mode of operation. This completes the 
programming instructions. The receiver will retain all of its programming even when power is removed. 

Page 2 REV A 06/17/20

LEARN

GAMA ELECTRONICS, INC.

WWW.GAMAINC.COM

RFR12VPRWP

GND +12V

MOTOR

Independent Contact

Closure

Power

Terminals

Motor
Terminals

Programming

Switch

Programming
LED

Long Range

Antenna Jack

Dip Switch

RFR12VPRWP

Instruction Manual

WWW.GAMAINC.COM

Summary of Contents for RFR12VPRWP

Page 1: ...is reverse polarity protected Power Consumption 10 Milliamperes when the relay is de energized 45 Milliamperes when the relay is energized Input output Connections 12VDC input power connects to the terminals marked 12V and GND on the top panel of the receiver The two white wires provide a set of dry contact closures using the ON OFF switch position on the transmitter Dimensions Receiver dimensions...

Page 2: ... program mode Release the button At this point all previously programmed transmitter addresses are erased from the receiver s memory 2 Press and release any button on the transmitter and verify that the red program LED extinguishes and then illuminates blinks once 3 Repeat previous step for additional transmitters that will operate with this particular receiver The red LED on the receiver will ext...

Page 3: ...long range option is purchased with the system this modification will be made prior to shipment To add long range functionality 1 Plug long range antenna Part number LRA 340 into the long range antenna jack 2 Clip the Long Range Antenna Bypass Wire This will deactivate the internal antenna NOTE It is recommended that you cover the exposed wires with RTV silicone sealant NOTE ONCE THE LONG RANGE MO...

Page 4: ...ntrol should be within this range 3 Reprogram the remote control If the system is non functional try to reprogram the remote control The program may not have taken during the programming process or the program button may have been pressed If the program button is pressed the memory of the remote controls programed to the receiver are erased 4 Listen and look for functionality on the receiver The L...

Reviews: