DIAGRAM 1

STEP 4 

BACK WALL

Join the two sheets 

C  

 together with 2 fixings through the overlapping 

ribs, making sure the ends of the sheets are flush. Cap the sheeting with 
the 1515mm 'U' channels 

F  

.

Fix the channels through the end ribs and every second rib in between. 
Make sure you put at least one fixing per sheet up through the underside 
of the channel into the pan of the sheet.

STEP 5 

ROOF

Join the two sheets 

D  

 together, same as the back. Cap the sheeting with the 1515mm 'U' 

channels 

F  

. Fix the channels at every second rib but not the corners at this stage. 

Place the short flange of the first 'L' flashing 

K  

 on top of the rib at one end. 

Make sure the ends are flush with the sheeting (diagram 1) and put  
one fixing in the centre to hold the 'L' flashing. Fix the corners  
through the channels and one more between the corner and  
the centre fixing. Perform the same at the other end.
Use five fixings in each 'L' flashing.

GALVO TIP

Put extra fixings in for  

high wind areas, particularly  

on the underside.

YOU WILL NEED

2 x 1830mm for the roof

2 x 1515mm 'U' channels for the roof

2 x 1830mm 'L' flashings

D

F

K

YOU WILL NEED

2 x 1830mm sheets

2 x 1515mm 'U' channels

C

F

F

F

C

F

F

K

K

D

Summary of Contents for GVO 1515

Page 1: ...iveter Tape measure Ladder Non slip gloves good shoes and goggles A set of helping hands CALL 0508 454 873 for an installer near you Some parts have sharp edges and should be handled very carefully We...

Page 2: ...ur supplier immediately if any discrepancies Remember to quote the code on the front page 1 x 1920 x 780mm door sheet 1 x narrow 1980 x 715mm sheet for front wall beside door 4 x 1980 1830mm sloping s...

Page 3: ...in the centre of the door sheet slipping it under the two side U channels and fixing it to the sheet ribs and the side U channels Attach the hinges N approx 150mm from the top and bottom of the door...

Page 4: ...r using wide flange fixings or screws ADDITIONAL INFORMATION Channels will come short of the ends of the sheeting by 10 15mm on all panels PADLOCK KEEPER ASSEMBLY KEEPER WASHER RIVET CHANNELS The high...

Page 5: ...he sheeting with the 1515mm U channels F Fix the channels at every second rib but not the corners at this stage Place the short flange of the first L flashing K on top of the rib at one end Make sure...

Page 6: ...you will have to run the Z s the opposite way to the diagram Rivet the Z s at the ends and in the centre of the channel it is tucked under and through the overlap in the centre Two or three more fixi...

Page 7: ...l of the front and the back walls 10mm more than the overhang Fix beside every second rib You will not need to worry about these fixings leaking as any water seeping through these fixings will end up...