Version 1, 24 August 2018, Page
3
of
4
INSTALLATION
IMPORTANT:
Galvin Engineering products must be installed in accordance with these installation
instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water
and/or electrical supply conditions must also comply to the applicable national and/or state standards. Failing
to comply with these provisions shall void the product warranty and may affect the performance of the
product.
1. Fit tap assembly
Remove the spout from the wall elbow
using a hex key. This is to enable easy
installation and prevent the spout being
damaged
2. Connect
Place the wall flange over the elbow. Fit the elbow
to the protruding wall spud. We recommend
using thread tape or an equivalent to ensure the
connection does not leak.
Ensure spout connection is pointing up (vertical).
3. Refit the spout
Refit the spout to the elbow. Tighten
the grub screw using a hex key.
Note: Do not overtighten grub screw.
Ensure spout swivels freely once installed.
4. Testing
Turn on the water supply and test for leaks.