background image

 

Version 1, 16 March 2017, 1 of 4 

Safe-Cell

®

 Prison Tapware 

 

PRODUCT CODE: 

 

 

50145 

 

SPECIFICATIONS

 

  The Safe-Cell

®

 Timeflow Push Button Valve is used in prisons, detention centres, high risk institutions, 

sporting facilities, schools and public area applications 

  Time is affected by temperature, flow rate and pressure, and is 

based on set at 500kPa, 4LPM @ 22˚C. 

  Once activated, this timed flow product will allow water to flow for approximately 15 seconds* 

 

Designed for easy bench installation (maximum thickness 10mm)

 

 

Note:  This is a single temperature product, so if warm water is required this needs to be premixed prior to reaching 
the valve. This can be done by using a CliniMix

®

 Thermostatic Mixing Valve. 

 

IMPORTANT:  All Safe-Cell

®

 prison taps are tested in accordance with AS/NZS 3718 and leave our premises 

in good working order.

 

 

TECHNICAL DATA

 

Inlet

 

½” BSP – Male 

Outlet 

½” BSP – Male 

Headwork 

Time flow cartridge 

Working Pressure Range (kPa)  

Min 

100 

Max 

500 

Working Temperature Range (°C) 

Min 

Max 

70 

Nominal Flow Rate (LPM) 

3 to 4.5 

Finish 

Chrome 

NOTE: Galvin Specialised continually strive to improve their products.  Specifications may change without notice.

 

 

PRE-INSTALLATION

 

MOUNTING DETAILS 

 

 

If the mounting holes do not already exist, mark out and drill the holes in the bench/trough, as shown in 
rough-in dimensions.

 

 

Please note the maximum thickness of the bench/trough is 10mm.

 

 

Reviews: