Version 1, 16 March 2017, 1 of 4
Safe-Cell
®
Prison Tapware
PRODUCT CODE:
-
50145
SPECIFICATIONS
The Safe-Cell
®
Timeflow Push Button Valve is used in prisons, detention centres, high risk institutions,
sporting facilities, schools and public area applications
Time is affected by temperature, flow rate and pressure, and is
based on set at 500kPa, 4LPM @ 22˚C.
Once activated, this timed flow product will allow water to flow for approximately 15 seconds*
Designed for easy bench installation (maximum thickness 10mm)
Note: This is a single temperature product, so if warm water is required this needs to be premixed prior to reaching
the valve. This can be done by using a CliniMix
®
Thermostatic Mixing Valve.
IMPORTANT: All Safe-Cell
®
prison taps are tested in accordance with AS/NZS 3718 and leave our premises
in good working order.
TECHNICAL DATA
Inlet
½” BSP – Male
Outlet
½” BSP – Male
Headwork
Time flow cartridge
Working Pressure Range (kPa)
Min
100
Max
500
Working Temperature Range (°C)
Min
5
Max
70
Nominal Flow Rate (LPM)
3 to 4.5
Finish
Chrome
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
PRE-INSTALLATION
MOUNTING DETAILS
If the mounting holes do not already exist, mark out and drill the holes in the bench/trough, as shown in
rough-in dimensions.
Please note the maximum thickness of the bench/trough is 10mm.