Galvin Specialised GalvinCare 50197 Product Installation Manualline Download Page 3

 

 

 

5. 

Fit the handle 

 

Fit the nylon insert and handle, ensuring the arrow on the 
handle matches the lines on the faceplate when rotated.  

 

Secure the handle with supplied tamper proof screw.

 

6. Testing 

 

Once fitted all parts & connected with 
controller, test body for  leaks and correct 
operation. 

 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

RECTIFICATION 

Faceplate does not sit flush on 
wall 

Diverter not mounted 
perpendicular to wall 

Remove and re-mount so the body is 
perpendicular to finshed wall 

Water flow does not match 
faceplate markings 

Handle not aligned correctly  
to faceplate 

Remove handle and rotate on the spline 
until handle matches faceplate. Re-tighten 

Outlet on body not connected 
to the correct service outlet 

Change outlet connection on body 

 

SERVICE AND MAINTENANCE

 

 

 

1. Turn off water 

  Turn off the water supply and turn on the tap 

handle to release any pressure in the lines 

  Disconnect the plug from controller 

  Disconnect cold, hot and inlet water 

connections 

2. Remove handle assembly 

 

Unscrew tamper proof screw from handle   

 

Pull out handle assembly from the body 

Summary of Contents for GalvinCare 50197

Page 1: ...igned for wall installation IMPORTANT All GalvinCare prison taps are tested in accordance with AS NZS 3718 and leave our premises in good working order TECHNICAL DATA Inlet BSP Male Outlet BSP Female Headwork Diverter Cartridge Working Pressure Range kPa Min 50 Max 500 Working Temperature Range C Min 5 Max 90 Finish Chrome Polished Stainless Steel NOTE Galvin Specialised continually strive to impr...

Page 2: ...le for horizontal and vertical mounting It is critical that the centre line of the cartridge spindle is perpendicular to the finished wall to ensure correct fitment of the faceplate and flange 2 Connect water supply Connect water supply to correct inlets as shown ensure a suitable sealing compound is used Connect correct outlet connection to shower outlet Note Water supply should be flushed before...

Page 3: ...t so the body is perpendicular to finshed wall Water flow does not match faceplate markings Handle not aligned correctly to faceplate Remove handle and rotate on the spline until handle matches faceplate Re tighten Outlet on body not connected to the correct service outlet Change outlet connection on body SERVICE AND MAINTENANCE 1 Turn off water Turn off the water supply and turn on the tap handle...

Page 4: ...r download from www galvinengineering com au Galvin Engineering Pty Ltd expressly warrants that the product is free from operational defects in workmanship and materials for the warranty period as shown on the schedule in the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long ...

Reviews: