background image

 

 

 

 

Version 2, 4 August 2017, Page 

3

 of 

5

 

Retro-Fit 

{Installation to existing Galvin Specialised Ezy-Wash Pre-Rinse unit (the unit will need to be isolated 

at the control valves)}

 

 

 

1.  Disassemble wall bracket 

  Unscrew the compression nut from the wall 

flange using two spanners (1

st

 to support the 

wall flange, 2

nd

 for the compression nut). 

 

Pull out support rod from wall flange and 
loosen the support rod from upper riser hook 
(if required).

 

2.  Disassemble pre-rinse riser 

 

Unscrew grub screw from top riser 
assembly.

 

 

Separate top riser, paying special 
attention to not damage any o-rings. 

 

Remove pre-rinse unit body from hub 
mounted assembly (if required). 

 

 

 

 

      

3.  Fit pot filler and riser 

  Remove protective cap from upper riser 

spindle

 

  Fit the upper riser to the lower riser, 

ensure the sealing o-rings are inside the 
spindle

 

  Tighten with new supplied grub screw

It is critical that the grub screw point 
locates accurately into hole recess of 
mating part. Failure to do so may result 
in damage and/or failure of the unit

.

 

4.  Fit pre-rinse riser assembly 

  Screw support rod into the riser hook and 

ensure it is not fully tightened (if applicable).

 

  Fit compression nut to support rod, 

followed by the compression cone and 
locate the support rod into wall bracket.

  Fit the pre-rinse riser assembly through the 

drilled hole on the bench and secure.

Summary of Contents for Ezy-Wash TF85-J

Page 1: ...gnifies hot water only If water other than hot is used e g cold then appropriate identification buttons will need to be purchased to replace those supplied on the standard unit TECHNICAL DATA Inlet Swivel spindle Outlet Aerator Headworks TF85 J Jumper Valve TF85 C Ceramic Working Pressure Range kPa Min 100 Max 500 Working Temperature Range C TF85 J Min 5 Max 65 TF85 C Min 5 Max 65 Nominal Flow Rat...

Page 2: ...plicable national and or state standards Failing to comply with these provisions shall void the product warranty and may affect the performance of the product New Installation The following instructions must be followed in all respects and read in conjunction with installation and operation instructions supplied with new pre rinse unit 1 Fit pot filler and riser Remove protective cap from upper ri...

Page 3: ...age any o rings Remove pre rinse unit body from hub mounted assembly if required 3 Fit pot filler and riser Remove protective cap from upper riser spindle Fit the upper riser to the lower riser ensure the sealing o rings are inside the spindle Tighten with new supplied grub screw It is critical that the grub screw point locates accurately into hole recess of mating part Failure to do so may result...

Page 4: ...ght etc so that the unit is not under mains pressure when unsupervised Flood damage may occur if a failure occurs whilst the unit is under mains pressure warranty is void in this instance Galvin Specialised recommends that the handpiece is periodically serviced by a qualified plumber IMPORTANT To seal the hose this unit uses Loctite 577 which is a thread sealant approved for use with potable water...

Page 5: ...ranties express or implied Galvin Engineering Pty Ltd hereby specifically disclaims all other warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Galvin Engineering Pty Ltd products are covered under our manufacturer s warranty available for download from www galvinengineering com au Galvin Engineering Pty Ltd ex...