Version 2, 16 August 2017, Page
3
of
4
3. Testing
Once the drinking tap has been installed and tested for leaks, the water height must be adjusted to
suit the available pressure.
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Inconsistent flow
Blocked top assembly
Remove top assembly and clean
Water is not flowing from tap
Water is turned off
Turn on water
Blocked flow restrictor
Remove restrictor and clean
Continuous flow
Top assembly loose or internally
obstructed or damaged
Remove top assembly, clean with water
and re-grease spindle if required
Rate of flow inadequate
The flow regulator screw may
not be adjusted correctly
Remove blanking screw and adjust flow
regulating screw as described
Button hard to press
The mains pressure may be too
great
Reduce to below 500kPa (70PSI).
Regrease spindle if required