PRE-INSTALLATION - 

MOUNTING DETAILS

 

 

 

If the mounting holes do not already exist, mark out and drill the holes in the wall/sheet, as shown in rough-in 
dimensions. 

 

Note: Before installation, all lines must be flushed.  We recommend that a line strainer be installed prior to drinking taps to 

eliminate any foreign material

 
 
 
 
 
 
 
 
 
 
 

 

                                                                                            Rough-In Dimensions 

 

 

 

 

 

 

INSTALLATION

 

IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with 
AS/NZS  3500,  the  PCA  and  your  local  regulatory  requirements.  Water  and/or  electrical  supply  conditions  must  also  comply  to  the 
applicable national and/or state standards. Failing to comply with these provisions shall void the product warranty and may affect the 
performance of the product.

 

 

 

1. Fit tap assembly 
 

 

Fit wall plugs to wall as per the rough-in dimensions.

 

 

When applying thread tape or sealant to the inlet, ensure the 
opening is not obscured. Failure to do so may restrict or 
block the flow restrictor, affecting the flow of water.

 

 

Screw tap onto existing spud until the flange is touching the 
wall. 

 

 

Ensure the mouthguard is in the correct position and the 
holes in the flange align with the wall plugs.

 

2. Secure the body 

  Secure the body with supplied screws. 

 