background image

 

Version 1, 3 August 2017, Page 

4

 of 

5

 

Version 2, 3 August 2017, Page 

4

 of 

5

 

 

 

 

              TF81HJS                              TF81HJP

 

 

       TF80H-S                                  TF80HJP

 

5.  Fit pre-rinse riser assembly 

1.  Fit compression nut to support rod, followed 

by the compression cone and locate the 
support rod into wall bracket.

 

2.  Fit the pre-rinse riser assembly through the 

drilled hole on the bench. 

 

6.  Secure pre-rinse assembly 

  Secure pre-rinse assembly with the supplied 

flanged back nut; ensure the sealing rubber 
washer is placed underneath the pre-rinse 
body flange.

 

 

 
 

 

 

 

 

 

 

 

 

 

             

TF81HJS                              TF81HJP

 

7.  Secure support rod 

1.  Fasten support rod securely against riser.

 

2.  Tighten compression nut on wall bracket to 

secure the support rod. The rod is now rigid.

 

8.  Test unit  

  Once all fittings have been tightened 

securely, connect the unit to the mains 
water. 

 

Turn  on  water  and  test  the  unit  for  any 
leaks. 