Galvin Engineering CliniMix Lead Safe 100.30.79.00 Product Installation Manualline Download Page 16

 

16 

 

Version 1, 21 August 2019, 16 of 21 

13.0 

WARRANTY 

The Galvin Engineering CliniMix

®

 Thermostatic Progressive Mixing Valves is guaranteed free from 

manufacturing faults for a period of 12 months, subject to the condition outlines below; 

GALVIN ENGINEERING PRODUCT WARRANTY 

Subject to the warranty conditions and exclusions set out below, Galvin Engineering products are warranted to 
be free from defects in materials and/or workmanship for a period of 12 months service life, and if found by 
Galvin Engineering to be so defective will be replaced as set out below. If the product is sold by a party other 
than Galvin Engineering, then it is sold by the seller as principal and the seller has no authority from Galvin 
Engineering to give any additional warranty on behalf of Galvin Engineering. 

The benefits of this warranty are in addition to all other rights and remedies which the purchaser may have under 
the Trade Practices Act or similar laws of each State and Territory in Australia. 

Warranty Conditions and Exclusions 

Conditions: 

1.  The TMV must have been installed by a licensed plumber in accordance with the Galvin Engineering 

Installation Instructions and Application Guidelines supplied with the valve, and in accordance with the 
National Plumbing and Drainage Code AS3500 (the Code) current at the date of installation and all 
relevant statutory and local requirements in the State or Territory in which the product is installed. 

2.  Where the product is installed outside the boundaries of a metropolitan area as defined by Galvin 

Engineering, the 

cost of transport insurance and travelling shall  e the purchaser’s responsi ility. 

3.  Where the valve comprises part of a hot water system, installation of that system must be in accordance 

with its manufacturer’s recommendation, the Code and all relevant statutory and local State or Territory 
requirements.   

4.  The valve must be returned to Galvin Engineering together with a fully and correctly completed Galvin 

Engineering Warranty Claim Form. 

5.  Where the valve is replaced under warranty the replacement valve carries a new warranty as detailed 

herein.  

Exclusions: 

Replacement work will be carried out as set out in the Galvin Engineering Warranty above, but the following 
exclusions may cause the warranty to become void, and may incur a service charge including cost of parts 
where: 

1.  Damage has been caused by accident, Acts of God, misuse, incorrect installation, incorrect installation of 

the water supply system of which the product forms a part or attempts to disassemble the valve. 

2.  It is found that there is nothing wrong with the product 

3.  The failure of the valve is due in part or in whole to faulty manufacture/installation of the hot water supply 

system of which the product forms part. 

4.  The valve has failed directly or indirectly as a result of excessive water pressure or temperature outside 

the Supply Pressure Requirements, or corrosive environment. 

5.  The valve has failed due to foreign matter either from installation or the water supply. 

6.  The failure of the valve is due to scale formation in the waterways of the valve. 

7.  The failure of the valve is due in part, or in whole, to installation not in conformance with the requirements 

of the Code. 

8.  Galvin Engineering reserves the right to change its specifications without prior notice and will not accept 

liability for any claim arising from such change. 

9.  Subject  to  any  statutory  provisions  to  the  contrary,  claims  for  damage  to  furniture,  carpets,  walls, 

foundations or any other consequential loss either directly or indirectly due to leakage from the valve are 
also excluded from warranty cover.

 

 

 

Summary of Contents for CliniMix Lead Safe 100.30.79.00

Page 1: ...s designed to comply with AS4032 Thermostatic Mixing Valves Materials Design and Performance Requirements The mixing valve has the following features Complies with the requirements of AS4032 4 Thermostatic Mixing Valves Provides high stability of mixed water temperature even under changing inlet conditions Ensures rapid shut down of mixed outlet flow in the event of hot or cold water supply failur...

Page 2: ...with proximity sensor These are designed to provide water in stable temperature for hand washing This mixing valve is supplied with integral isolating valves strainers check valves and flow regulators and is provided with a facility for thermal disinfecting of the cold inlet side and mixed water outlet for the wall mounted version only The hot side of the body and the inlet is insulated to ensure ...

Page 3: ...in with proximity sensor Preset line purge feature interval 12 hours after last flush water flow duration 3 min Preset continuous run 5 min Sensor range Sensor1 and Sensor2 custom made steps 5 0 WATER SUPPLY CONDITIONS 5 1 INTRODUCTION This progressive sequential thermostatic mixer with proximity sensor is manufactured to the highest standards and has approval to AS4032 4 which permits it to be in...

Page 4: ... in AS NZ3666 and local legislation shall be adhered to If the valve is not installed correctly then it will not function correctly and may put the user in danger It may also void the warranty of the valve Prior to the installation of the valve the system must be checked to ensure that the system operating conditions fall within the recommended operating range of CliniMix Progressive Thermostatic ...

Page 5: ...eve 200mm centre to centre of the connectors Note The use of thread tape is recommended to ensure bases stay in the required position and are water tight 3 Fit progressive mixer Fit chrome sleeves to fitted isolator connectors Tighten loose nuts on the body to the isolator connectors already on the wall ensuring the strainer seal is in between Do not over tighten 4 Secure Sensor Install the proxim...

Page 6: ... and symbols Touch function Hand object within sensor area Water flows LED flashes Green Water flow stops LED flashes Red H hours min minutes sec seconds FUNCTION PROCEDURE FEEDBACK SIGNAL INFORMATION DEFAULT SETTING RANGE Via IQUA Touch First startup After installation 1x app 4 sec till Remove hand object from sensor area wait 2x sec keep out of sensor area wait till 1x Confirmation ready for ope...

Page 7: ...x 40x according to setting line purge feature activate deactivate Automatic flush on set interval time of waterflow 3 min 1x app 2 sec till 1x extended function mode is active 12h Off 12 h 24 h 48 h 1x app 25 sec till 1x 4x 1x off 2x 12h 3x 24h 4x 48h ignore flashes after 5 sec and 10 sec keep touched till 1x 4x after app 25 sec releasing defines interval Wait till 1x Confirmation ready for operat...

Page 8: ...utting off the hot and cold supplies while the mixer is set in the full hot position Shut Down Test 1 With the mixer still on and with both supplies turned on allow the mixed water temperature to stabilise for at least 15 seconds and note the outlet temperature While holding a digital thermometer in the outlet flow quickly isolate the cold water supply to the valve The outlet flow should quickly r...

Page 9: ...lushing procedure care should be taken to prevent water damage occurring to the surrounding area t is a requirement of AS3500 4 2 that Each thermostatic mixing valve shall have an isolating stop tap valve line strainer and non return valve fitted to the hot and cold water supply lines The inlet fittings supplied with each TMV will ensure this requirement is met If the CliniMix Progressive Thermost...

Page 10: ...e results are to be compared against original commissioning settings If there are no significant changes at the mixed temperature outlet then a 6 monthly servicing cycle may be adopted Otherwise servicing checks should be carried out more frequently e g every 4 months Follow the recommended maintenance procedures detailed in section 10 During servicing note the following 1 Repeat the procedure of ...

Page 11: ...red can now be re installed by screwing into the mixer body until it reaches a firm stop and tightened Re fit the cover and re commission the mixer as per commissioning procedure When service is complete slowly open the cold water isolation valve and inspect mixer body for leaks Repeat with hot water isolation valves Commence commissioning process Annual Maintenance Procedure Every 12 months the t...

Page 12: ...ower supply from proximity sensor 2 Remove top cap screw and cover 3 The setting rings are located either side of the tap stop to stop movement of the tap spindle 4 Remove both rings and turn tap spindle till desired temperature is achieved 5 Reposition both rings on either side at the tap stop so that the tap spindle cannot move 6 Refit the cover the screw and the top cap 10 2 Removal and inspect...

Page 13: ...tion 10 1 6 After fitting the new cartridge start the test procedure from the section 7 0 on commissioning Record the mix temperature 10 3 Important notes on debris Although this product is protected by built in filters debris can still find its way to the thermostat housing area This can happen during servicing for example Remove cartridge see section 10 2 and carry out an inspection 10 4 Mainten...

Page 14: ... isolation valves through 90 anti clockwise see picture 1 below 4 Unscrew the two plugs see picture 2 elow and fit the two 3 x fittings from the Disinfection kit WM PMDK Fit the supplied flexi hose between these fittings see pictures 3 and 4 below 5 Now turn the hot isolation valve clockwise see picture 5 below 6 Turn on the mixer Hot water will now pass from the hot inlet through the by pass hose...

Page 15: ...f the fitting the strainer elements should be checked and cleaned in accordance with the commissioning and servicing guide See section 7 and 9 To access the strainer element first slide forward the shrouds and close the isolation valves Unscrew the connection nut using metric spanner 30mm and detach the unit from the wall See section 9 2 for the assembly drawing to locate the strainer The strainer...

Page 16: ...that system must be in accordance with its manufacturer s recommendation the Code and all relevant statutory and local State or Territory requirements 4 The valve must be returned to Galvin Engineering together with a fully and correctly completed Galvin Engineering Warranty Claim Form 5 Where the valve is replaced under warranty the replacement valve carries a new warranty as detailed herein Excl...

Page 17: ...down The hot to mix temperature differential is not 10 C or greater Thermostatic cartridge contains debris or is damaged Non return devices are damaged Raise hot water temperature Clean the cartridge ensuring that all debris is not jammed Clean if necessary Mix temperature unstable Flow rate below 6 L min Thermostatic cartridge contains debris or is damaged Strainers contain debris Non return devi...

Page 18: ..._____ Temperature of Cold Water to the Valve ________________ Hot Water Pressure ________kPa Cold Water Pressure _______kPa Make of Mixing Valve _______________________ Model No ________________________ Size __________ Valve Location Building _____________________________________________________________________ Valve Identification No _______________________________________________________________...

Page 19: ... is hereby certified that all the commissioning work has been carried out by the undersigned in accordance with the requirements of the Codes of Practice indicated prior Date of Valve Commissioned __________________________________________________________________________ Name of Licensed Plumber _______________________________ License Cert No ______________________ License Plumbers Signature _____...

Page 20: ...arm Water C One Outlet in Use All Req d Outlets in Use One Outlet in Use All Req d Outlets in Use 1 2 3 4 5 6 7 8 9 10 11 Give details of brand and model designation Commensurate with the design flow rate for the mixing valve Note An accurate digital thermometer is necessary for the temperature measurements Prescribed temperature range for warm water ______________ C to _________________C Thermal ...

Page 21: ..._______________________________Signature ______________________ Date _______________________ Maintenance Tests Yes Date of Previous Service ______________________________________________ Previous Service carried out by _________________________________________ Reason for Maintenance Tests _______________________________________________________________ This Test and report Witnessed by ____________...

Reviews: