background image

 

© Galvin Engineering Pty Ltd 

 

Product Installation Guidelines 

Document No.: 001.00.10.08 

 

Version 1, 12 July 2022, Page 

1

 of 

5

 

 
 
CliniLever

®

 CP-BS Hospital Wall Sink Set Taps  

w/ 190 Gooseneck Outlet 

 

PRODUCT CODES:

 

 

 

 

TCWSC150C    -  TCWSC80C 

TCWSJ150C     -  TCWSJ80C  

 

SPECIFICATIONS

 

 

The  CliniLever

®

  product  range  is  primarily  used  for  hand  washing  applications  in  hospitals,  aged  care 

facilities, schools and in-home care. 

 

CliniLever

®

 products provide state of the art features to comply with the latest healthcare guidelines.  

 

Contra rotating handles to ensure ease of use  

 

Laminar flow aerator supplied as standard to reduce the spread of legionella. 

 

Smooth round design to facilitate easy cleaning and to help reduce dirt and bacterial growth. 

 

Quick action SBA’s includes brass jumper valve / ceramic  disc component, with red and blue indicator 
buttons on 80mm or 150mm lever action handles.

 

IMPORTANT: All CliniLever

®

 healthcare taps are tested in accordance with AS/NZS 3718 and leave our 

premises in good working order.

 

 

TECHNICAL DATA

 

Inlet

 

1/2

” BSP – Female 

Outlet 

Laminar Flow Aerator 

Headwork 

Jumper Valve / Ceramic Disc 

Working Pressure Range (kPa)  

Min 

50 

Max

 

500 

Working Temperature Range (°C) 

Min 

Max 

65 

Nominal Flow Rate (LPM) 

5.5 

Finish 

Chrome 

NOTE: Galvin Engineering continually strive to improve their products.  Specifications may change without 
notice.

 

 

TOOLS REQUIRED

 

  Power drill

 

  Spanner and hex key

 

  Thread tape

 

 

Summary of Contents for CliniLever TCWSC150C

Page 1: ...educe the spread of legionella Smooth round design to facilitate easy cleaning and to help reduce dirt and bacterial growth Quick action SBA s includes brass jumper valve ceramic disc component with red and blue indicator buttons on 80mm or 150mm lever action handles IMPORTANT All CliniLever healthcare taps are tested in accordance with AS NZS 3718 and leave our premises in good working order TECH...

Page 2: ...unted between 0 and 15mm behind the finished wall surface Wall spud Wall spud must be BSP male thred and protrude from the finished wall by no more than 15mm Note In some situations a male thread connection on the spout may be more suited If so please contact us on 1300 514 074 Note Before installation all lines must be flushed We recommend that a line strainer be installed prior to taps to elimin...

Page 3: ...r the elbow Fit the elbow to the protruding wall spud We recommend using thread tape or an equivalent to ensure the connection does not leak Ensure spout connection is pointing up vertical 2 Refit the spout Refit the spout to the elbow Tighten the grub screw using a hex key Note Do not overtighten grub screw Ensure spout swivels freely once installed 3 Fit Spindle Assembly Remove handle and flange...

Page 4: ...lace jumper valve Ceramic discs are worn or damaged Remove and inspect SBA Remove debris and or replace SBA if damaged Tap seat is damaged Refurbish tap seat using a reseating tool Water is leaking from spindle O ring on jumper valve spindle is damaged or worn Replace o ring Water is not flowing from tap Water is turned off Turn water on Aerator or flow regulator is blocked by debris Remove aerato...

Page 5: ...Galvin Engineering Pty Ltd makes no other warranties express or implied Galvin Engineering Pty Ltd hereby specifically disclaims all other warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Galvin Engineering Pty Ltd products are covered under our manufacturer s warranty available for download from www galvineng...