© Galvin Engineering Pty Ltd
Product Installation Guidelines
Version 3, 27 August 2021, Page
1
of 4
CliniLever
®
CP-BS Hospital Wall Mixing
Set Type 51 Fixed 150 C/D
PRODUCT CODES:
-
TC51FC1C
SPECIFICATIONS
−
The CliniLever
®
product range is primarily used for hand washing applications in medical facilities,
hospitals, aged care facilities, schools and in-home care.
−
CliniLever
®
products provide state of the art features to comply with the latest healthcare guidelines.
−
The dual levers for on/off, hot and cold temperature have a straight forward operation which simplifies
hand washing.
−
All CliniLever
®
products provide laminar flow (not aerated).
−
Our highly sought after lever handle design are easily operated with elbows or wrists to avoid hand
contact.
−
The main body is made of solid dezincification resistant (DR) brass rod, with a DR brass gooseneck
outlet.
−
Quick action SBA’s includes brass ceramic cartridge component, with red and blue indicator button on
150mm lever action handles.
IMPORTANT: All CliniLever
®
healthcare taps are tested in accordance with AS/NZS 3718 and leave our
premises in good working order.
TECHNICAL DATA
Inlet
½” BSP – Female
Outlet
Laminar Flow
Headwork
Ceramic Disc
Working Pressure Range (kPa)
Min
50
Max
500
Working Temperature Range (°C)
Min
5
Max
65
Nominal Flow Rate (LPM)
5.3
Finish
Chrome
NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without
notice.
TOOLS REQUIRED
−
Power drill
−
Spanner
−
Hex key
−
Thread tape