Galvamet SHARP Installation, Operating And Maintenance Instructions Download Page 3

 

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR COOKER HOOD MODEL SHARP 

230-240 Vac - 50 Hz 

 

Exhausting  cooker  hood.  The  equipment  is  constructed  in  accordance  with  European  Standards  and  with  the  requirements  included  in  the  following  Directives:  2006/95EC  (  Low  Voltage 

Directive), 2004/108 (Electromagnetic Compatibility). 
 
INSTALLATION 
Read the instruction manual before installing and/or using the hood. 

The  unit  must  be  fitted  at  a  distance  of  at  least  65  cm.  from  the  cooking  hob.  If  the 
mounting instructions of the gas cooker indicate a wider distance, respect it. The unit must 

not be mounted above cookers fitted with top radiant plate.  
Respect all the air discharge regulations. 

The air must not be discharged in a pipe used to discharge exhaust fumes produced by 
gas-fed equipments or fuel-fed equipments (this does not apply to filtering hoods). 

The room must be adequately ventilated when the hoods is used together with other gas-
fed or fuel-fed equipments. 

For an easy access, it is advisable to move possible furniture under the installation area.  
 

Installation of the hood onto the wall. 
The  hood  is  equipped  with  all  the  necessary  fastenings  for  its  installation,  which  are 

suitable for most surfaces. Anyway ask a professional to verify that the installation surface 
is strong. 

Installation must be carried out by qualified installers according to present regulations. 
 

 

Drill the wall as indicated on the drawing 1 

 

Insert the hood and fix it with the fixing supports (A) 

 

Open the light covers (B) as indicated on the drawing and fix the supports with the 
screws underneath the light covers 

 
ELECTRICAL CONNECTIONS 
This equipment must be connected to a grounding plant. 
Two types of electrical connection can be used: 

1) 

Using a standard plug to be connected to the power cable and inserted in a mains 
socket  which  must  be  accessible  (so  that  the  plug  can  be  disconnected  when 

servicing  is  carried  out).  Make  sure  that  the  plug  is  accessible  also  after  the 
complete installation of the equipment. 

2) 

By  means  of  a  fixed  mains  connection,  fitting  a  bipolar  switch,  which  ensures the 
disconnection,  with  an  opening  distance  of  the  contacts  allowing  a  complete 

disconnection  on  the  conditions  of  the  overvoltage  III  category,  according  to 
installation  regulations.  The  ground  connection  (yellow-green  wire)  must  not  be 

interrupted. 

Refer to the plate inside the hood for the mains voltage and frequency ratings. 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent 
or similarly qualified persons in order to avoida hazard. 

 
EMPLOYMENT 
 

This cooker hood can be employed as exhausting or filtering. 

Exhausting  (external  evacuation).  Kitchen  smokes  are  driven  outside  through  a  flue 
joined to the exhaust pipe flue connector. 
 

This  pipe  must  not  under  any  circumstances  be  connected  to  cooker,  boiler  or  burner 
exhaust pipes, etc. 

Filtering (inside recycling). Smokes pass through the activated charcoal filter (Picture 2 - 

C) to be cleaned and recycled in the kitchen. 
In this case you should not install the exhaust pipe without curve. 

 
MAINTENANCE 
Always  disconnect  the  hood  from  the  mains  before  carrying  out  any  maintenance  or 

cleaning operation. 

 
Particular attention should be paid to the metallic anti-grease filters that are designed to 
trap particles of fat contained in the fumes. The metallic anti-grease filters must be washed 

at least once a month with detergent in hot water (or in the dish-washer). 
ATTENTION:  the  grease  collected  in  the  filters  can  easily  catch  fire  and  it  is  therefore 

extremely important to clean the metallic filters on a regular basis as per instructions.  
The  activated  charcoal  filters  are  designed  to  collect  unpleasant  odours  in  the  cooking 

fumes. The air is then released purified in the environment. The charcoal filters must not 
be washed, but replaced 2 or 3 times a year, depending on how much the hood is used. 

New filters are to be requested directly to the manufacturer. 
In  order  to  replace  the  activated  charcoal  filters,  turn  the  filters  until  they  unfasten  from 

aspirator. 
Invert the operation in order to install the new charcoal filters. 

 
In order to remove the remaining glue or any impurity, the cooker hood must be cleaned 

immediately after installation and after having removed the protective film. 
The cooker hood must be cleaned frequently both internally and externally (at least once a 

month). 
Do not let dirt gather on the inner and outer surfaces of the hood. 

To  clean  the  exterior  of  the  hood  do  not  use  either  acid  or  basic  products,  or  abrasive 
sponges. 

Clean  the  hood  with  a  sponge  dampen  in  warm  water  and  a  little  quantity  of  neutral 
detergent  (for  example  dishwasher  detergent),  in  order  to  remove  possible  particles  of 

grease. 
Rinse  with  a  damp  cloth,  removing  all  the  detergent  carefully,  following  the  satin  finish 

direction on the steel surface. 
Drying is  very important,  especially in  areas where  water  is  particularly  hard  and  leaves 

limestone. 
 

To replace the lamp dichroic just pry with a screwdriver (Pic.3) 
Replace the lamp only with an analogous one (halogen max. 20 W, 12 Volts). 

 
WARNINGS 
 
The present instruction manual is an integral part of the appliance itself, therefore it must 

be carefully kept and ALWAYS accompany it, even in case of its assignment to another 
owner or user or in case the cooker hood is moved to another installation plant. 

Any  eventual  adjustment  to  the  electrical  system,  which  may  be  necessary  to install  the 
cooker hood, must be carried out only by competent people. Any repair carried out by no 

competent people may cause damages. For any repair or needed technical action make 
reference  to  a  Technical  Assistance  Center,  which  is  authorized  to  carry  out  the 

replacement  of the spare parts. 
Always  make  sure  that  all  the  electrical  parts  (lights,  exhaustion  unit)  are  disconnected 

when the appliance is not in use. 
By storms take off the main switch of the house electrical system. 

The  using  of  the  cooker  hood  must  not  be  other  than  the  use  of  exhausting  units  for 
cooking damps on domestic kitchens. The manufacturer does not accept any liability for 

damages caused by people, animals or  things, by installation and maintenance mistakes 
or by any illegitimate use. 

Make  sure  that  the  voltage  (V)  and  the  frequency  (Hz)    ratings  indicated  on  the  plate 
inside the cooker hood correspond to the ones available in the installation place. 

 
We  remind  that  the  use  of  products  functioning  with  electrical  energy  implies  the 

observance of some essential security rules, as follows: 

 

This equipment is not intended for people (children included) with reduced mental 
or  motor  capacities,  with  lack  of  experience  or  knowledge,  unless  they  are 

supervised or unless a person responsible for their security, gives them instructions 
regarding  the  use  of  the  equipment.  Children  must  be  supervised  in  order  to  be 

sure that they do not play with the equipment.  

 

Any cleaning action is forbidden if the appliance hasn’t been disconnected  from the 

main power supply and if the main switch of the house electrical system is not off. If 
cleaning is not carried out according to these instructions, a fire may break out. 

 

Do not pull, take off or twist the cable coming out from the appliance, even though 
this has been disconnected from the main power supply. 

 

Do not sprinkle or throw any water directly on the appliance. 

 

Do not stick any sharp tool inside the exhausting holes and into the air discharge. 

 

Do  not  take  out  the  filters  in  order  to  reach  the  internal  sides  of  the  appliance  in 
case the main switch of the house electrical system is not off. 

 

Do  not  singe or flambé  directly  underneath  the  cooker  hood.  Take  particular  care 
when frying to ensure that the oil does not catch fire. 

GB 

 
OPERATION 

The hood is supplied with a multispeed motor. 
The hood should be run at low speed under normal conditions and at higher speeds only 
when there is a heavy build-up of fumes or odours.  
Ideally, the hood should be switched on as soon as cooking is started and then kept on 
until all odours have been eliminated.  
The controls consist of touch screen commands. Press TL to turn on the light, press T1 to 
swich on the hood at first speed and to switch off the aspirator, press T2-T3-T4 to select 
functioning speeds.  
 
Adjustable and delayed self switching off  
Choose the desired speed while the hood is working, then keep the speed button pressed 
until  it starts blinking. This button corresponds to the desired self switching off minutes. 
Please keep in mind that: 
T1 corresponds to 5 minutes 
T2 corresponds to 10 minutes 
T3 corresponds to 15 minutes 
T4 corresponds to 20 minutes 

 

Filters maintenance reminder 
Aluminium anti-grease filters 
Once the hood is switched off, after 30 hour functioning, all the leds of the speed buttons 
switch on with a fixed light for 30 seconds to remind that aluminium anti-grease filter need 
cleaning.To set the timer to zero keep the button T4 pressed with the aspirator switched 
off, otherwise the timer will remain set on 30 hour functioning and the reminder will occur 
again when the hood is switched off again.  
Charcoal filter (for filtering hoods) 
Once the hood is switched off, after 120 hour functioning, all leds blink for 30 seconds to 
remind that the charcoal filter need cleaning. 
To  set  the  timer  to  zero  keep  the  button  T4  pressed  with  the  aspirator  switched  off, 
otherwise  the  timer  will  remain  set  on  120  hour  functioning  and  the  reminder  will  occur 
again when the hood is switched off again. 

Summary of Contents for SHARP

Page 1: ...SHARP 230 240 Vac 50 Hz cod 395 278 2...

Page 2: ...spugna inumidita con acqua calda ed una modesta quantit di sapone neutro es sapone per stoviglie al fine di eliminare le particelle di grasso eventualmente depositate sulla stessa Risciacquare con un...

Page 3: ...neutral detergent for example dishwasher detergent in order to remove possible particles of grease Rinse with a damp cloth removing all the detergent carefully following the satin finish direction on...

Page 4: ...de savon neutre ex savon pour vaisselle afin d liminer les particules de graisse qui pourraient s tre d pos es sur la hotte Rincer avec une chiffon humide en ayant soin d enlever tous les r sidus de s...

Page 5: ...e la campana con un pa o humedecido en agua caliente y con una peque a cantidad de detergente neutro ej detergente para lavavajillas para eliminar las part culas de grasa que se pueden haber depositad...

Page 6: ...m ssen alkaline oder s urehaltige Produkte oder Scheuerschw mme vermieden werden Die Abzugshaube mit warmem Wasser unter sp rlichem Zusatz von Neutralseife z B Geschirrsp lmittel und mit weichem Schwa...

Page 7: ...r produto cido ou b sico ou esponjas abrasivas Limpar o exaustor com uma esponja humedecida com gua e uma pequena quantidade de sab o neutro ex detergente de lou a de forma a eliminar as part culas de...

Page 8: ...endo em conta que T1 corresponde a 5 minutos T2 corresponde a 10 minutos T3 corresponde a 15 minutos T4 corresponde a 20 minutos Aviso de manuten o de filtros Filtro anti gordura em alum nio Ap s cada...

Page 9: ...__________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________...

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: