Installation and operation manual - Galmet solar systems
29
6. Mounting and connecting the diaphragm vessel
6. Mounting and connecting the diaphragm vessel
6.1. Mounting the diaphragm vessel
(A) - elastic pipe ¾" connects the safety valve of the solar safety group.
(B) - gasket.
(C) - stopping valve designed to disconnect the diaphragm vessel in a quick and efficient way,
without any leakage of the glycol (option).
(D) - diaphragm vessel with a ¾ ” connection.
(E) - Type L mounting bar with wall plugs and mounting screws. Mount the bar (E) on the
wall. Diaphragm vessel (D) to the stopping valve (C) and place it on the L bar in a place it was
designed, then tighten the locking nut. Place the gasket (B) on the stopping valve and tighten
the nut on the elastic pipe (A).
6.2. Replacing the diaphragm vessel
Stopping valve mounted on the L bar holds the diaphragm vessel and allows for a quick
detaching without the risk of glycol leakage.
Unscrewing of the stopping valve's nut (F) allows for easy replacement of the diaphragm
vessel. The top but of the stopping valve can NOT be unscrewed!
The two sides of the stopping valve have a lock valve, which prevents the leakage of the glycol
in case diaphragm vessel is disconnected and from the vessel itself after unscewing the top
nut of the stopping valve.
Re-tightening of the diaphragm vessel's nut (F) will result in opening of the stopping valve
and connection the system without any leakage of the glycol.