TELEPHONE DESCRIPTION

TELEPHONE DESCRIPTION

escription of the T

-940 Plus telephone.

D

a.

b.

c.

d.

e.

f.

g.

h.

i.

Telephone handset.

Speaker grille.

Microphone hole.

Subjection hole.

Telephone cord connectors.

Function push buttons.

On-

Off light indicator

.

Call reception volume control.

Hook switch.

a

d

c

e

i

h

e

b

f

g

The telephone has a three positions switch placed on the bottom

     part of the telephone (closest to the telephone cord connector)

     that allows to control the call reception level volume.

unction push buttons.

F

On-

Off push button.

     After any telephone reset, and during the next 45 seconds,

     all the telephone functions will be disabled, with the exception

     of call reception.

This push button allows to make an intercom call when the handset

     is not on the craddle. This function is described on page 27.

If the handset is on the craddle sends a panic call to the porter's

     exchanges that have enabled the reception of this type of call.

     If not, allows to call to the master porter's exchange.

     During call reception and communication progresses allows

     the lock release activation.

a.

b.

c.

a

b

c

erminal connector description.

T

positive, ground.

audio, digital communication.

intercom.

auxiliary calling device output.

door bell push button input.

+ , 

 :

A , D :

INT :

SA :

HZ

- :

AD

+

_

SA

INT

HZ-

TELEPHONE INST

ALLA

TION

ix the telephone.

F

It will be necessary to open the telephone for wiring and

     fixing purposes. T

o

 open the telephone insert a plain

      screwdriver into the slots and rotate it as shown.

Avoid to place the telephone near to

     heating sources, in dusty locations or

     smoky environments.

The telephone can be fixed using an

     electrical embedding box or directly

     on the wall, as shown on the picture.

     If the telephone will be installed directly

     over the wall, drill two holes of Ø6mm.

     on the specified positions, using 6mm.

     wallplugs and Ø3,5 x 25mm. screws.

Pass the installation wires through the corresponding hole and

     connect them as shown on the installation diagrams.

Close the telephone as shown on the picture. Once the telephone

     is closed, connect the handset using the telephone cord and

     put it on the craddle.

Summary of Contents for 295 series

Page 1: ...T300EN rev 0204 Instructions manual Audio and Video door entry system digital installation 295 Series ...

Page 2: ...Troubleshooting hints 29 INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our customers is stated through the ISO 9001 certification and for the manufacturing of products like this one Its advanced technology and exacting quality control will do that customers and users enjoy wi...

Page 3: ...ithout the visitor being aware of this To see the picture in a slave monitor press the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system will be freed O To establish communication pick up the monitor telephone handset The communication will last for one and a half minutes or until the handset is replaced Once the communication has finish...

Page 4: ...e CD 295 2nd push buttons module CD 295 2nd push buttons module CD 295 L1 L2 CD1 CN2 CD2 CP L1 L2 CN1 CP CD L1 L2 CN1 CP CD 1 9 17 3 11 19 5 13 21 7 15 23 8 16 24 6 14 22 4 12 20 2 10 18 DOOR PANEL INSTALLATION old the door panel on the embedding box H Insert the hinge in the embedding box lockers Press the hinge ends to insert them in the door panel lockers as shown oor panel wiring D Open the te...

Page 5: ...general entrance panel this function can be activated in one door panel of each internal building Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is finished return the switch to OFF position The programming process is described on pages 15 monitors and 18 telephones Set to OFF the switch number 3 in case of a master door panel Each system must hav...

Page 6: ...or panel C Fix the door panel to the embedding box by using the supplied vandal resistant screws and the special screwdriver inal adjustments F To install the power supply directly on the wall drill two holes of Ø6 mm and insert the wallplugs Fix the transformer with the specified screws The power supply can be installed on a DIN 46277 guide simply pressing it To disassemble the power supply from ...

Page 7: ...O Floor Door Stair PLATEA Plus 0000000000 Nº serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment holes Identification label Connecting points CN4 connector Three positions call reception volume control Cable slot Contrast control color control in case of color screen Brightness control Monitor...

Page 8: ...tional device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L561 module for video installations E with twisted pair cable andling the end of line jumper H hanging the front film C The end of line jumper is placed on the CN4 connector that can be located on the monitor base In case of twisted pair cable installations the end of line jumper is placed in the...

Page 9: ...de In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release push button With the door release push button pressed switch on the monitor To show that the system is ready for programming the door panel will reproduce a sound and the picture will appears on the mo...

Page 10: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description Tpositive ground audio digital communication intercom auxiliary calling device output door bell push button input A D INT SA HZ A D _ SA INT HZ TELEPHONE INSTALLATION ix the telephone F It will be necessary to open the teleph...

Page 11: ...aves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set to OFF the programming switch If you don t the door panel will reproduce a sound to advise that the system is still into programming mode INSTALLATION DIAGRAMS onnexion of an a c lock release C As it...

Page 12: ...el as shown on the diagram In case of more than two door panels wire them as the second is connected 1 00mm 2 50mm 0 25mm 0 25mm RG 59 RG 59 Terminal SECTIONS CHART 50m Distance 150m A A A D in out V V V V in out in out CV CV For longer distances than the specified contact with your distributor Take off JP1 jumper of all the distributors except in the last one FA Plus C SEC PRI SEC PRI SW1 SW1 CV ...

Page 13: ...er distances than the specified contact with your distributor ideo installation without coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the diagram In cas...

Page 14: ...panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second is connected For longer distances than the specified contact with your distributor FA Plus C SEC PRI SEC PRI SW1 SW1 CV CV CV CV D D Malla...

Page 15: ...SCART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17 shield and 20 hot of the SCART connector ntercom function I Platea Plus monitor and T 940 Plus telephone have intercom facility between two units of the same apartment To enable this function che...

Page 16: ...e wiring from the door panel and to check a monitor or telephone directly connected to the door panel No shortcircuit will damage the connected units with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c If not disconnect the power supply from the install...

Page 17: ... el derecho a cualquier modificación sin previo aviso Golmar se réserve le droit de toute modification sans préavis Golmar reserves the right to make any modifications without prior notice golmar golmar es www golmar es ...

Reviews: