Gallien-Krueger MB110 Owner'S Manual Download Page 6

MB  SERIES COMBOS

ON

OFF

ON

OFF

ON

OFF

ON

OFF

INPUT

PHONES

DIRECT OUT

P O W E R

AUX-IN

P AT C H

B AY

A C T I V E

E Q U A L I Z E R

O U T P U T

I N P U T

GAIN

CONTOUR

TREBLE

HI-MID

LO-MID

BASS

BOOST

MASTER

LIMITER

HORN

-10dB

POST

PRE

19

18

20

NOTE:

FOR USE WITH GK MBP SERIES

POWERED CABINETS ONLY.

CHAIN OUTPUT

AC INPUT

SPEAKER

OUTPUT

Input:

 A standard 1/4" input to connect 

instruments using a shielded cable.

-10dB:

 Used to reduce the input signal from 

active instruments or other high input sources.

Gain:

 Sets the preamp gain after the input 

stage. It is used in conjunction with the input 

pad to optimize the amplifier’s headroom.

Contour:

 In the on position the button 

decreases the mid-range frequencies while 

boosting low and high frequencies.

Treble:

 Boost and cut at 7 kHz shelving type. 

Use this control to add or remove edge and 

definition.

Hi-Mid:

 Boost and cut at 1 kHz. A “Q 

optimized,” band pass type works on lower 

string harmonics and effects the punch of your 

sound.

Lo-Mid:

 Boost and cut at 250Hz. A “Q 

optimized” band pass type, effects the main 

body of your sound.

Bass:

 Boost and cut at 60Hz, shelving type 

used to control the low end push.

Boost:

 Adds a post EQ gain stage using 

G.I.V.E. technology adding “growl” as it is 

turned up.

Master:

 The master volume is used to 

control the overall output level.

Limiter:

 When this button is engaged it 

prevents the power amp from distorting. It is 

recommended that this feature is used for high 

volume applications.

Horn:

 Activates the high frequency tweeter.

Aux In:

 This 1/8" input for a CD or MP3 

player allows the user to monitor an external 

audio source.

Phones:

 

Headphone output. When the phones 

are connected, the signal sent to the speaker is 

interrupted.

Balanced Direct Out:

 This electronically 

balanced output allows a direct connection to 

a P.A. system.

Pre/Post: 

This button selects the direct out 

signal to be before or after the EQ.

Power Switch:

 Turns the amplifier on and off. 

In the on position, the ring surrounding the 

button will light red during power up then 

changes to blue, indicating the amp is ready 

for normal operation. Should the amp 

experience a fault (over heat or over current) 

the amp will mute and the ring will light red 

until the condition is corrected. This LED 

turns off when the power is switched off. This 

turns the amp off but it does not completely 

disconnect the power from the AC mains.

Rear Panel

Chain Out:

 This XLR output sends all EQ and 

volume settings to Gallien-Krueger MBP 

series powered cabinets. This connection is 

made with a standard XLR mic cable.

AC Receptacle:

 The detachable power cord 

connects here.

Speaker Out (MB210 only):

 Power amp 

output to an external speaker cabinet. A twist 

lock Speakon connector allows the connection 

of a cabinet with an 8 ohm minimum load.

  

2

3

4

5

6

7

8

9

11

12
13

14

1

10

MB210, MB212, MB115, MB410 Control Panel Features

15

16

17

18

19

20

MB115 Control Panel 

1

2

3

4

5

6

7

8

9

10 11 12 13

14

15 16

17

Summary of Contents for MB110

Page 1: ...MB Combo OWNER S MANUAL ...

Page 2: ...se contact your local dealer or GK as soon as possible Gallien Krueger Inc 2234 Industrial Drive Stockton CA 95206 phone 209 234 7300 fax 209 234 8420 Internet www gallien krueger com Email info gallien com We wish you a lifetime of good playing and remember to always have fun GK Philosophy I have never seen the point in doing things the way others have done them I also have not been very interest...

Page 3: ...and specifications are subject to change without notice Gallien Krueger 2234 Industrial Drive Stockton CA 95206 phone 209 234 7300 fax 209 234 8420 email info gallien krueger com internet www gallien krueger com Warning This amplifier is capable of producing high sound pressure levels Continued exposure to high SPL s can cause damage to your hearing Always set the volume at a safe listening level ...

Page 4: ...nditioners or refrigerators This will lessen the possibility of power variation and electrical start up noise affecting your sound AC Power Cord To avoid safety hazards use only the power cord supplied with your unit If a replacement cord is needed make certain to use a standard IEC compliant cord Damaged power cords should be replaced immediately When setting up make certain that the AC plug is e...

Page 5: ...ment really needs The fact is graphic equalizers are intended for room equalization The equalization in Gallien Krueger amplifiers reflects 40 years of continuous development and refinement The GK equalizer is unique to the industry it s not just a normal four band equalizer each section is a special circuit optimized to perform a Bass specific job in its range of operation These sections are wire...

Page 6: ...he power amp from distorting It is recommended that this feature is used for high volume applications Horn Activates the high frequency tweeter Aux In This 1 8 input for a CD or MP3 player allows the user to monitor an external audio source Phones Headphone output When the phones are connected the signal sent to the speaker is interrupted Balanced Direct Out This electronically balanced output all...

Page 7: ...ody of your sound Bass Boost and cut at 60Hz shelving type used to control the low end push Aux In This 1 8 input for a CD or MP3 player allows the user to monitor an external audio source Phones Headphone output When phones are connected the signal sent to the speaker is interrupted Balanced Direct Out This electronically balanced output allows a direct connection to a P A system Pre Post This bu...

Page 8: ... to monitor an external audio source Phones Headphone output When phones are connected the signal sent to the speaker is interrupted Power Switch Turns the amplifier on and off In the on position the ring surrounding the button will light red during power up then changes to blue indicating the amp is ready for normal operation Should the amp experience a fault over heat or over current the amp wil...

Page 9: ...fety Requirements Specifications 9 10dB ON OFF INPUT PRE POST AMP AMP AMP Output Power MB210 II 350W 8 Ohms internal 500W 4 Ohms w extension MB212 II 500W 4 Ohms MB410 500W 4 Ohms MB115 II 200W 4 Ohms MB112 II 200W 4 Ohms MB110 100W 6 Ohms Input Section Maximum Input Level 0 6V rms Input Impedance 1M Ohms Direct Output Impedance 500 Ohms Aux in Input Impedance 100K Ohms Equalizer Bass 10dB 60Hz Lo...

Page 10: ...MB Combo Owners Manual Part 160 0520 F ...

Reviews: