Gallien-Krueger 8000RB Service Manual Download Page 7

8)

Engage Hi-boost switch, compare to Fig. 12. (Disengage).

9)

Engage Bi-amp switch. Compare 100W output to Fig. 13.

10)

Compare 300W output to Fig. 14.

11)

Set Freq. Knob 10, compare 100W output to Fig. 15.

12)

Compare 300W output to Fig. 16. Disengage Bi-amp switch.

Noise Test
1)

Remove oscillator input.

2)

Turn front panel knobs to 10, switches out.

3)

Connect speaker to 100W output and listen for noise. It should be smooth and not crackling. Repeat for 300W
output.

4)

Change AC voltmeter range to 1V

5)

Noise( both amplifier outputs) should measure less than 400mV.

6)

Engage low-cut, contour, and hi-boost. Noise<400mVrms.

7)

Volume to 0.  Noise< 110mVrms.

8)

Boost to 0. Noise<15mVrms.

9)

Engage bi-amp switch. 100W noise< 20mVrms, 300W noise< 5mVrms.

RETURN KNOBS TO ZERO, SWITCHES OUT- READY FOR BURN-IN.

Summary of Contents for 8000RB

Page 1: ...Service Manual 800RB ...

Page 2: ...Table of Contents Operating Instructions 3 Turn On Calibration Procedure 6 Schematics 11 Engineering Change Orders ECOs 24 Bill of Materials 34 ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ...3 Adjust variac to 120V and turn speaker OFF 4 Set bias 300W adjust R38 on 44 board for 5mV DC across R48 R49 R50 most pos of the 3 and R54 R55 R56 most neg of the 3 5 Set bias 100W adjust R14 for on 44 board for 5mV across R25 R26 6 Power LED and boost LED should be lit 7 Connect oscillator to input 200 Hz 46dBV 8 Turn on 4 ohm load for 300W amp and 8 ohm load for 100W amp 9 Adjust volume for sli...

Page 7: ...nput 2 Turn front panel knobs to 10 switches out 3 Connect speaker to 100W output and listen for noise It should be smooth and not crackling Repeat for 300W output 4 Change AC voltmeter range to 1V 5 Noise both amplifier outputs should measure less than 400mV 6 Engage low cut contour and hi boost Noise 400mVrms 7 Volume to 0 Noise 110mVrms 8 Boost to 0 Noise 15mVrms 9 Engage bi amp switch 100W noi...

Page 8: ...ut on both amps 100W 32 Vrms 300W 40Vrms B Check master pots when looking at output of both amps 10 Turn loads off 11 Connect square wave input 200 Hz 20 mVp p 44dB A Boost on zero volume at 2 o clock B Test attenuation and filters C Test tone control D Turn on bi amp check if crossover works on both high and low amps NOTE When test filters tones and crossover compare w figures 12 Turn bi amp off ...