5 pERFORMANCES

5.1 

COOLING MODE: MODELS WITH 1 HEAT ExCHANGER

Tbs

Air inlet temperature (dry bulb)

Tbu

Air inlet temperature (wet bulb)

Tw

Water inlet temperature

Tw

Outlet water temperature

pFT 

Total cooling capacity

pFS 

Sensible cooling capacity

qw 

 

Water flow rate

Dpw 

Pressure drop, water side

vin  

Inverter control voltage

qa  

Air flow rate

Lw  

Sound power level

Tbs1 / Tbu1 (UR%)

27 °C / 19 °C (47%)

 Tw1 / Tw2  

6 / 11 °C

7 / 12 °C

8 / 13 °C

9 / 14 °C

Model

vin

qa

Lw

pFT

pFS

qw

Dpw

pFT

pFS

qw

Dpw

pFT

pFS

qw

Dpw

pFT

pFS

qw

Dpw

v

m3/h dB(A)

W

W

l/h

kpa

W

W

l/h

kpa

W

W

l/h

kpa

W

W

l/h

kpa

1

2,8

149

30

880

630

151

5

770

590

132

4

660

550

113

3

570

520

99

2

3,6

189

32

1050

750

181

6

920

700

158

5

770

650

133

4

640

600

109

3

4,4

231

40

1310

930

225

9

1150

870

197

7

980

800

167

5

780

730

134

4

6,3

342

48

1520 1050

260

12

1330

980

228

10

1120

910

193

7

900

830

155

5

7,0

380

52

1610 1100

276

13

1410 1030

242

11

1190

950

205

8

960

870

165

5

8,3

450

55

1760 1190

302

16

1540 1110

264

12

1310 1030

224

9

1050

940

181

6

3

3,7

196

32

1360

960

233

9

1200

900

206

8

1030

830

176

6

830

760

143

4

4,0

211

38

1430 1020

245

10

1260

950

216

8

1080

880

185

6

880

800

151

4

5,2

271

44

1720 1220

296

14

1520 1140

261

11

1300 1060

223

9

1060

970

182

6

6,4

344

49

1980 1390

339

18

1740 1300

298

14

1490 1210

256

11

1210 1110

209

8

7,0

380

52

2170 1530

372

21

1910 1430

328

17

1630 1330

281

13

1340 1220

230

9

8,3

450

55

2410 1690

413

26

2120 1580

364

20

1820 1470

312

15

1490 1350

255

11

4

3,7

196

32

1450 1010

249

7

1290

940

221

6

1110

870

191

4

920

800

158

3

4,0

211

40

1530 1070

263

8

1360 1000

234

6

1180

930

202

5

970

850

167

3

5,2

271

44

1910 1330

328

12

1700 1240

292

9

1480 1150

253

7

1230 1060

211

5

6,4

344

50

2210 1510

379

15

1960 1420

337

12

1700 1320

292

9

1410 1210

242

7

7,0

380

52

2610 1810

448

20

2330 1690

399

16

2020 1570

347

13

1690 1450

291

9

8,3

450

55

2940 2030

504

24

2620 1900

449

20

2270 1770

390

15

1900 1630

326

11

4M

3,7

196

33

1560 1060

268

11

1410 1000

242

9

1250

930

215

7

1080

860

185

5

4,0

211

41

1660 1130

285

12

1500 1060

258

10

1330

990

228

8

1140

920

196

6

5,2

271

45

2050 1400

351

17

1850 1320

317

14

1640 1230

281

11

1410 1140

242

9

6,4

344

51

2480 1700

426

24

2240 1600

384

20

1980 1500

340

16

1700 1400

293

12

7,0

380

53

2680 1850

461

27

2420 1740

415

23

2140 1630

368

18

1840 1520

317

14

8,3

450

56

3060 2110

525

34

2760 1990

473

28

2440 1870

419

23

2100 1740

361

17

5

2,9

211

26

1570 1110

270

8

1400 1040

239

6

1190

960

205

5

960

870

164

3

3,4

241

35

1800 1260

309

10

1600 1180

275

8

1380 1090

237

6

1120

990

193

4

5,1

341

43

2290 1670

392

15

2030 1570

348

12

1760 1460

301

9

1450 1350

249

7

6,5

442

48

2720 2000

467

20

2420 1880

415

16

2100 1760

360

13

1740 1620

299

9

7,7

528

50

3080 2360

528

25

2740 2230

470

20

2370 2090

407

16

1870 1870

320

10

8,5

579

52

3260 2530

560

28

2900 2390

498

22

2510 2250

431

17

1980 1980

340

11

6

2,9

211

26

1740 1190

299

5

1530 1100

263

4

1380 1030

236

3

1230

980

211

2

3,4

241

34

1990 1360

341

6

1760 1260

302

5

1500 1150

258

4

1320 1080

227

3

5,1

341

42

2670 1820

459

10

2380 1700

408

8

2060 1570

353

6

1680 1420

289

4

6,5

442

48

3290 2260

564

14

2930 2110

503

11

2540 1950

436

9

2110 1790

362

6

7,7

528

50

3780 2560

648

18

3370 2390

579

15

2930 2210

503

11

2440 2030

419

8

8,5

579

52

4050 2730

694

20

3610 2550

619

16

3140 2360

538

13

2620 2170

450

9

6M

2,9

211

27

1880 1250

323

7

1700 1170

292

5

1500 1090

258

4

1340 1020

230

4

3,4

241

35

2130 1420

366

8

1930 1330

331

7

1710 1240

293

5

1460 1140

250

4

5,1

341

43

2910 1950

499

14

2640 1830

453

12

2340 1710

403

10

2020 1580

347

7

6,5

442

49

3640 2450

624

21

3290 2300

565

17

2930 2150

503

14

2530 1990

435

11

7,7

528

51

4210 2850

723

27

3820 2680

655

23

3390 2510

583

18

2940 2330

505

14

8,5

579

53

4540 3080

779

31

4110 2900

706

26

3660 2710

628

21

3160 2510

544

16

7

2,7

320

35

2280 1570

391

6

1980 1450

340

4

1610 1310

277

3

1400 1230

240

2

4,0

450

43

3000 2190

514

9

2630 2040

451

7

2220 1880

381

5

1800 1790

309

4

5,9

640

52

3980 2930

682

15

3510 2750

602

12

3000 2560

515

9

2410 2410

414

6

7,4

798

56

4500 3420

772

19

3970 3220

681

15

3400 3000

583

11

2740 2740

471

8

8,0

855

57

4700 3600

807

20

4150 3390

712

16

3550 3170

610

12

2870 2870

493

8

8,8

938

60

4990 3850

855

23

4400 3630

755

18

3770 3400

648

14

3050 3050

524

9

Summary of Contents for ESTRO BLDC FAI

Page 1: ...TECHNICAL MANUAL GB ESTRO BLDC ESTRO BLDC FAN COILS BRUSHLESS TECHNOLOGY 1 5 kW 9 0 kW ...

Page 2: ...ons 22 24 7 Wiring diagrams 25 8 VERSIONS WITH SEPARATE INVERTER 26 8 1 Inverter regulation procedure 26 8 2 Inverter board 27 8 3 Alarms 27 9 VERSIONS WITH INTEGRATED INVERTER 28 10 Accessories 29 31 11 Installation requirements 32 12 Maintenance 32 Thetechnicalanddimensionaldataprovidedhereinmayundergochangesinconnection with product improvements Operating limits thermal carrier fluid water wate...

Page 3: ...r pumps water circulation pumps etc Another analog output makes it possible to control the modulating valves Permanent magnets electric motor mounted on vibration damping couplings complete with winding thermal protection The unit is equipped with an inverter board to control the motor which can be used separately or installed on the motor itself features below By means dipswitches this system mak...

Page 4: ...by a net easily removable for maintenance operations The filter is secured to the cabinet with turn screws FAI Wall mounting Cabinet composed of a thick steel sheet panel 10 10 mm side panels and air outlet grille swinging by 180 built from ABS The side doors make it possible to access the technical compartments and the control panel accessory Bearing structure built from thick galvanised steel sh...

Page 5: ...motor made with antistatic ABS with blades having an airfoil section and offset modules or aluminium Honey comb polypropylene washable air filter mounted on a galvanised sheet frame protected by a net easily removable for maintenance operations The filter is secured to the cabinet with turn screws FC Vertical horizontal recess mounted Bearing structure built from thick galvanised steel sheet thick...

Page 6: ...for horizontal installation fan coils with cabinet FUI Motor driven valves and drip trays VK S 3 way valve with ON OFF electrothermal motor and hydraulic kit for standard heat exchanger ALL VK DF 3 way valve with ON OFF electrothermal motor and hydraulic kit for DF heat exchanger FLI FAI FUI FPI FCI FFI GIVK Valve body insulation shell ALL BV Auxiliary water drip tray for vertical installation fan...

Page 7: ...lable Water flow l h 118 132 149 178 187 201 136 137 156 177 187 201 136 137 156 177 187 201 not available Pressure drop kPa 3 4 4 6 7 8 5 5 7 8 9 10 5 5 7 8 9 10 not available Water connections std inches 1 2 1 2 1 2 1 2 DF inches 1 2 1 2 1 2 not available Water content std dm3 0 5 0 5 0 7 0 9 DF dm3 0 2 0 2 0 2 not available ESTRO BLDC 1 2 5 6 6M 7 Motor speeds 3x Min Med Max Min Med Max Min Med...

Page 8: ... 10 11 12 Water connections std inches 1 2 1 2 1 2 1 2 DF inches not available 1 2 not available 1 2 Water content std dm3 1 33 1 4 1 8 1 4 DF dm3 not available 0 4 not available 0 4 ESTRO BLDC 1 2 9M 95 11 11M Motor speeds 3x Min Med Max Min Med Max Min Med Max Min Med Max 6x no 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 Total cooling capacity 1 kW 3 0 3 5 4 4 5 4 5 8 6 2 2 9 3 4 4 2 5 3 5 8...

Page 9: ...730 147 4 4 0 211 41 1450 1000 248 9 1280 930 219 7 1100 850 188 6 890 770 153 4 5 2 271 45 1780 1240 305 13 1570 1150 270 11 1350 1060 232 8 1110 960 190 6 6 4 344 51 2160 1500 370 19 1910 1400 327 15 1640 1290 281 11 1340 1180 230 8 7 0 380 53 2330 1630 400 21 2060 1520 354 17 1770 1400 304 13 1450 1280 249 9 8 3 450 56 2660 1870 456 27 2350 1740 403 21 2010 1610 346 16 1650 1470 284 11 5 2 9 21...

Page 10: ...3 3 1880 1560 322 3 1630 1460 281 2 4 2 470 43 3020 2160 519 6 2560 1970 439 5 2040 1770 351 3 1770 1660 304 3 5 5 605 49 3700 2720 635 9 3170 2510 545 7 2550 2260 438 5 2160 2150 371 4 7 3 785 56 4570 3400 784 13 3950 3150 677 10 3240 2880 557 7 2690 2690 463 5 8 0 855 57 4790 3630 821 15 4130 3360 709 11 3400 3080 584 8 2830 2830 486 6 8 8 938 60 5110 3910 876 16 4410 3630 757 13 3650 3340 626 9...

Page 11: ...1080 860 185 5 4 0 211 41 1660 1130 285 12 1500 1060 258 10 1330 990 228 8 1140 920 196 6 5 2 271 45 2050 1400 351 17 1850 1320 317 14 1640 1230 281 11 1410 1140 242 9 6 4 344 51 2480 1700 426 24 2240 1600 384 20 1980 1500 340 16 1700 1400 293 12 7 0 380 53 2680 1850 461 27 2420 1740 415 23 2140 1630 368 18 1840 1520 317 14 8 3 450 56 3060 2110 525 34 2760 1990 473 28 2440 1870 419 23 2100 1740 36...

Page 12: ...0 386 4 1910 1670 329 3 4 2 470 43 3570 2490 613 9 3170 2320 544 7 2710 2140 466 5 2150 1920 370 4 5 5 605 49 4350 3120 747 12 3870 2920 664 10 3340 2710 574 8 2730 2480 469 5 7 3 785 56 5360 3890 919 18 4770 3650 818 14 4140 3400 710 11 3430 3140 589 8 8 0 855 57 5610 4140 963 19 5000 3900 857 16 4330 3640 744 12 3600 3360 618 9 8 8 938 60 5990 4460 1027 21 5330 4200 914 17 4620 3930 794 14 3850 ...

Page 13: ...90 456 15 6920 306 7 4M 3 7 196 33 1430 249 8 2260 197 5 2900 254 7 3930 174 4 4 0 211 41 1530 265 9 2400 210 5 3080 270 8 4180 185 4 5 2 271 45 1880 328 12 2960 259 8 3800 333 12 5140 227 6 6 4 344 51 2290 397 17 3590 313 11 4620 405 16 6220 275 8 7 0 380 53 2480 430 20 3880 339 12 5000 439 19 6730 297 9 8 3 450 56 2820 490 25 4420 386 16 5700 500 24 7660 338 11 5 2 9 211 26 1550 270 6 2450 214 4...

Page 14: ...12 9 3 4 389 39 3030 526 6 4790 418 3 6120 537 5 8370 369 3 4 2 470 43 3310 575 6 5190 454 4 6690 588 6 9060 400 3 5 5 605 49 4080 709 9 6400 559 6 8250 724 9 11120 491 4 7 3 785 56 4980 866 13 7790 681 8 10080 884 12 13530 597 6 8 0 855 57 5700 992 17 8940 782 10 11550 1013 16 15540 686 8 8 8 938 60 6100 1061 19 9550 835 12 12350 1084 18 16590 732 9 9M 3 4 389 40 2990 520 7 4720 413 5 6020 529 7 ...

Page 15: ...40 434 14 6670 294 7 4M 3 7 196 33 1300 226 6 2120 185 4 2760 242 7 3790 167 3 4 0 211 41 1390 241 7 2260 197 5 2930 258 7 4030 178 4 5 2 271 45 1710 297 10 2780 243 7 3620 318 11 4960 219 5 6 4 344 51 2080 361 15 3370 294 10 4390 386 15 5990 265 7 7 0 380 53 2250 391 17 3650 318 11 4760 417 17 6480 286 9 8 3 450 56 2560 445 21 4150 362 14 5430 476 22 7370 326 11 5 2 9 211 26 1410 245 5 2300 201 4...

Page 16: ...7 11 9 3 4 389 39 2750 478 5 4490 393 3 5830 511 5 8050 356 2 4 2 470 43 3000 521 5 4870 426 4 6370 559 6 8720 385 3 5 5 605 49 3700 643 8 6010 525 5 7850 689 8 10710 473 4 7 3 785 56 4510 785 11 7320 639 7 9590 842 11 13030 575 6 8 0 855 57 5180 900 14 8400 734 9 10990 964 15 14960 661 7 8 8 938 60 5530 962 16 8970 784 10 11760 1031 16 15970 705 8 9M 3 4 389 40 2720 472 6 4440 388 4 5740 504 6 79...

Page 17: ...4 860 150 7 1330 116 4 1780 156 7 2320 102 3 6 4 344 49 980 170 8 1510 132 5 2020 177 8 2620 115 4 7 0 380 52 1030 180 9 1590 139 6 2130 187 9 2760 122 4 8 3 450 55 1110 193 11 1710 149 6 2290 201 10 2960 131 5 4DF 3 7 196 32 740 128 5 1130 99 3 1530 134 5 1980 87 2 4 0 211 40 750 131 5 1160 101 3 1560 137 5 2020 89 2 5 2 271 44 860 150 6 1330 116 4 1780 156 6 2310 102 3 6 4 344 50 980 170 8 1500 ...

Page 18: ...14 7 4790 420 11 6240 275 5 6 6 706 53 2460 427 13 3790 331 8 5050 443 12 6580 290 6 8 0 855 57 2680 467 15 4130 361 9 5520 484 14 7170 317 7 8 8 938 60 2800 487 16 4310 377 10 5770 506 16 7480 330 7 9DF 3 4 389 39 1790 311 5 2760 241 3 3670 322 5 4820 213 2 4 2 470 43 1970 343 6 3050 266 4 4040 355 6 5290 234 3 5 5 605 49 2260 393 8 3490 305 5 4650 408 8 6060 268 4 7 3 785 56 2580 448 10 3970 347...

Page 19: ...1 44 770 134 6 1240 108 4 1690 149 6 2230 98 3 6 4 344 49 880 153 7 1400 123 4 1920 168 8 2510 111 3 7 0 380 52 930 161 8 1480 129 5 2020 177 8 2650 117 4 8 3 450 55 1000 174 9 1590 139 6 2180 191 9 2840 126 4 4DF 3 7 196 32 660 114 4 1050 92 2 1450 127 4 1900 84 2 4 0 211 40 670 117 4 1080 94 3 1480 130 4 1940 86 2 5 2 271 44 770 134 5 1230 108 3 1690 148 6 2220 98 3 6 4 344 50 870 152 6 1400 122...

Page 20: ...294 6 4550 399 10 6000 265 5 6 6 706 53 2210 385 11 3540 310 7 4800 421 11 6320 279 5 8 0 855 57 2420 420 12 3860 338 8 5250 460 13 6890 304 6 8 8 938 60 2520 438 13 4030 352 9 5480 480 14 7190 317 7 9DF 3 4 389 39 1600 279 4 2570 225 3 3490 306 5 4630 204 2 4 2 470 43 1770 308 5 2840 248 3 3840 337 6 5090 225 3 5 5 605 49 2040 354 7 3260 285 4 4420 387 7 5830 257 3 7 3 785 56 2320 403 9 3710 324 ...

Page 21: ... 40 5 9 640 45 00 51 20 48 50 42 50 37 90 28 50 18 40 49 7 4 798 51 00 57 20 54 50 48 50 43 90 34 50 24 40 55 8 0 855 53 00 59 20 56 50 50 50 45 90 36 50 26 40 57 8 8 938 55 00 61 20 58 50 52 50 47 90 38 50 28 40 59 Octave band 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz GLOBAL Model Speed Vin Qa Lw Lw Lw Lw Lw Lw Lw Lw setting V m3 h dB dB dB dB dB dB dB dB A 7M 1150 2 7 320 28 70 37 20 ...

Page 22: ...84 226 708 51 458 163 263 149 198 187 335 99 486 7 9 1194 226 918 51 458 163 263 149 198 187 335 99 486 95 1194 251 918 48 497 185 259 155 220 195 348 120 478 11 1404 251 1128 48 497 185 259 155 220 195 348 120 478 Overall dimensions of CLI wall mounted with cabinet vertical air flow 1 Clearance for water connection 2 Slots for installation on the wall 3 Clearance for electrical connections 4 Stan...

Page 23: ...208 198 5 6 984 226 708 51 458 163 263 1187 335 99 486 208 198 7 9 1194 226 918 51 458 163 263 1187 335 99 486 208 198 95 1194 251 918 48 497 185 259 195 348 120 478 234 208 11 1404 251 1128 48 497 185 259 195 348 120 478 234 208 Overall dimensions of FPI ceiling mounted with cabinet rear air intake 1 Clearance for water connection 2 Slots for installation on the wall 3 Clearance for electrical co...

Page 24: ...l DF 5 Drain outlet 6 Air outlet 7 Air intake FCI A B C D E F G H L M N P Q R S T U V Y 1 4 584 224 498 51 458 163 263 149 198 187 335 99 189 486 208 198 436 464 61 5 6 794 224 708 51 458 163 263 149 198 187 335 99 189 486 208 198 646 674 61 7 9 1004 224 918 51 458 163 263 149 198 187 335 99 189 486 208 198 856 884 61 95 1004 249 918 48 497 185 259 155 220 195 348 120 215 478 234 208 856 884 67 11...

Page 25: ... sensor SU Humidity sensor DI1 Digital 1 input DI2 Digital 2 input CI12 Digital input common For each fan coil a switch IL should be mounted on the power supply with opening contacts at a distance of at least 3 mm and a suitable protection fuse F A B GND RS 485 F Fuse not supplied IL Circuit breaker not supplied VC Solenoid valve Cooling VH Solenoid valve Heating Electrical connections to be made ...

Page 26: ...ip switched as shown in the following figure No MAX speed DIP 1 DIP 2 DIP 3 DIP 4 1 1550 rpm OFF OFF OFF 2 1450 rpm ON OFF OFF 3 1350 rpm OFF ON OFF 4 1250 rpm ON ON OFF 5 1150 rpm OFF OFF ON 6 1050 rpm ON OFF ON 7 950 rpm OFF ON ON 8 850 rpm ON ON ON TABLE OF SPEED RAMP SELECTION Note Generally the max speed 1550 rpm is not used 8 VERSIONS WITH SEPARATE INVERTER 8 1 INVERTER REGULATION PROCEDURE ...

Page 27: ...all copying even par tial of this manual is strictly forbidden FC66003632 Rev 00 27 ESTRO BLDC 8 VERSIONS WITH SEPARATE INVERTER 8 2 INVERTER BOARD 8 3 ALARMS ...

Page 28: ...end 1 Strip Molex Micro Fit 3 0 04365 00400 to be used with 04364 50400 1 1 10V 1 2 Tachometer outlet 1 3 0 10V lin signal PWM 1 4 GND 2 Lumberg 3642 03 K01connector to be used with 3626 03 K01 2 1 PE ground 2 2 N neutral 2 3 L phase 3 fastening points ELECTRICAL CONNECTION VERSIONS WITH INVERTER INTEGRATED IN THE MOTOR ASSEMBLY VOLUTE ...

Page 29: ...signedfortheinstallation on éstro FLI models are supplied in pairs and comprisesupportsforfasteningtothebaseunit andoutercoveringsforfasteningtothecabinet They are used to conceal the plumbing pipes leading up from the floor and in cases where the fan coil unit cannot be anchored to the wall The height of covering feet is 100 mm ZLG Pair of support covering feet with front grille for FLI models Th...

Page 30: ...24V transformer The automatic closure and opening of the louver can be obtained by means of external auxiliary contacts not supplied as anti freeze thermostats timers etc by connecting in parallel several servomotors to a single opening closing control The louver should be coupled to one of the following control panels optional CSB installation on the unit and CSD wall recess mounted permitting to...

Page 31: ...up to 8 l h of water RA RM Inlet and outlet connectors These accessories are designed for éstro BLDC FCI FFI fan coils and are used for room ducts when the basic unit éstro BLDC FCI is placed within false ceilings and or recess wall mounted For each configuration the inlet and outlet connectors are available in straight version and in 90 jointed version GIVK Valve insulation shell The GIVK valve i...

Page 32: ...he user to set the functions while ensuring an accurate reading of the ambient temperature if provided You should avoid positions directly exposed to sunlight positions exposed to direct currents of warm or cold air placing obstacles that impede an accurate temperature reading During wintertime periods of quiescence drain water from the system to prevent ice from forming If anti freeze solutions a...

Reviews: