4
| Part Number: 3E2453 R1
Installation Note | Gallagher T10 Mifare Reader
Using the drill template at the back of this installation note as a
1.
guide, drill all three holes. Drill the 13mm (1/2 inch) diameter centre
hole (this is the centre hole for which the building cable will exit the
mounting surface) and the two fixing holes.
Run the building cabling out through the centre hole and through the
2.
reader base.
Secure the base to the mounting surface using the two fixing screws
3.
provided. It is important the base of the reader is flush with and tight
against the mounting surface.
Note: Ensure the centre hole allows the cable to run freely out through
the mounting surface, so that the reader facia can clip into the base.
Base
6 Gauge screw
Building cable
6 Gauge screw
Connect the reader tail extending from the facia assembly to the
4.
building cable. Connect the wires shown below.
Note: Do not cut the ‘Reserved’ wires, they may be required later.
Positive
Red
Negative
Black
Reserved
Orange
Reserved
Green
Reserved
Brown
CDXIV TX
White
CDXIV RX
Blue
Cardax IV Reader
Fit the facia assembly into the base by clipping the small lip, into the
5.
top of the base and holding the top, press the bottom of the facia
assembly down into the base.