background image

3E4205 Gallagher S40 Portable Solar Energizer User Manual

IMPORTANT INFORMATION

WARNING: READ ALL INSTRUCTIONS

• 

WARNING

 - The appliance is not intended for use by young children or 

infirm persons without supervision.

 

• 

It is recommended that, in all areas where there is a likely presence of unsupervised children who will be 

unaware of the dangers of electric fencing, that a suitably rated current limiting device having a resistance 

of not less than 500 ohms be connected between the energizer and the electric fence in this area.

• 

Young children should be supervised to ensure that they do not play with the appliance.

 WARNING: For the purposes of recharging the battery, only use the G40110 detachable supply unit 

 

                    provided with this energizer.

• 

When using the Gallagher safety isolating power supply, ensure the energizer and power supply are used 

in a sheltered, well ventilated area fully protected from rain, condensation and other sources of moisture.

• 

Refer servicing and replacement batteries to a Gallagher Authorised Service Centre.

• 

Regularly inspect the supply cord, cables, wires and energizer for any damage. If found damaged in any 

way, immediately cease use of the energizer and return it to a Gallagher Authorised Service Centre for 

repair in order to avoid a hazard.

• 

Check your local council for specific regulations.

• 

Except for low output battery operated energizers, the energizer earth stake should penetrate the ground 

to a depth of at least 1 m (3 ft).

• 

Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.

• 

Well maintained electric fences kept clear of vegetation with high quality insulation are extremely unlikely 

to cause fires. In times of extreme fire risk, disconnect energizer.

• 

Electric animal fences and their ancillary equipment shall be installed, operated and maintained in a 

manner that minimizes danger to persons, animals or their surroundings.

• 

Do NOT become entangled in the fence. Avoid electric fence constructions that are likely to lead to the 

entanglement of animals or persons.

•  WARNING - INSTALLERS/USERS SHOULD NOTE: 

Avoid contacting the fence with the head, mouth, neck or 

torso. Do not climb over, through or under a multi-wire electric fence. Use a gate or a specially designed 

crossing point.

• 

An electric animal fence shall not be supplied from two separate energizers or from independent fence 

circuits of the same energizer.

• 

For any two separate electric animal fences, each supplied from a separate energizer independently timed, 

the distance between the wires of the two electric animal fences shall be at least 2.5m. If this gap is to be 

closed, this shall be effected by means of electrically non-conductive material or an isolated metal barrier.

• 

Barbed wire or razor wire shall not be electrified by an energizer.

• 

A non-electrified fence incorporating barbed wire or razor wire may be used to support one or more 

off-set electrified wires of an electric animal fence. The supporting devices for the electrified wires shall 

be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm from 

the vertical plane of the non-electrified wires. The barbed wire and razor wire shall be earthed at regular 

intervals.

• 

Follow the energizer manufacturer’s recommendations regarding earthing.

• 

A distance of at least 10 m shall be maintained between the energizer earth electrode and any 

Summary of Contents for S40

Page 1: ...Instructions Instrucciones ENG ESP PORTABLE SOLAR FENCE ENERGIZER S40...

Page 2: ...ISCLAIMER Whilst every e ort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisi...

Page 3: ...360O MOUNTING Red Green Table of Contents English 4 Espa ol 13 Red Green RED GREEN EARTH STAKE RED...

Page 4: ...kept clear of vegetation with high quality insulation are extremely unlikely to cause fires In times of extreme fire risk disconnect energizer Electric animal fences and their ancillary equipment sha...

Page 5: ...8 If connecting leads and electric animal fence wires are installed near an overhead power line their height above the ground shall not exceed 3 m This height applies either side of the orthogonal pro...

Page 6: ...minimum degree of protection IPX4 This energizer complies with international safety regulations and is manufactured to international standards Gallagher reserves the right to make changes without not...

Page 7: ...clean so battery will charge from the sun 5 Earth Terminal Connects to earth ground stake 6 Fence Terminal Connects to fence 7 Voltage Indicator Green pulse Fence Voltage is OK Red pulse Fence voltag...

Page 8: ...r panel should face towards the equator i e in the northern hemisphere panel faces south in the southern hemisphere panel faces north Avoid placing in a shady area 5 Connect leads a Connect green term...

Page 9: ...ight to control nocturnal animals Full Power The energizer slows the pulse rate at night to conserve power allowing it to deliver a higher energy pulse during the day when animals are active Note In p...

Page 10: ...battery to charge Ensure energizer is getting enough sun Turn energizer off for 3 days leave in sun to charge battery Connect Recharge Kit G40110 to charge battery Battery indicator flashes red No bat...

Page 11: ...y charged Recharge battery before and after storage Maintenance free battery The battery must not be opened and does not require maintenance Battery replacement Use only 6 V 10 Ah sealed valve regulat...

Page 12: ...product indicates that this product packaging and with special care of the battery must not be disposed of with other waste Instead it is your responsibility to dispose of your waste equipment by han...

Page 13: ...a pastores a bater a de baja potencia la toma de tierra debe penetrar en el suelo no menos de 1 m El cableado de la cerca se debe instalar bien lejos de cualquier l nea de tel fonos tel grafos o anten...

Page 14: ...e puede evitar debe realizarse por debajo de la l nea de alta tensi n y lo m s cerca posible en ngulo recto Si los conectores y los cables de la cerca el ctrica son instalados cerca y por encima de la...

Page 15: ...dor Se debe proteger de la climatolog a el equipo auxiliar a menos que el fabricante certifique que el equipo es adecuado para su uso en el exterior y es del tipo con un grado de protecci n m nima IPX...

Page 16: ...OFF Energ a media Energ a m xima 3 Sensor de luz Utilizado para determinar si es de d a o de noche 4 Panel solar Mant ngalo limpio para que la bater a se cargue con el sol 5 Terminal de tierra Se cone...

Page 17: ...tornille para acceder a la bater a la bater a necesita conectarse antes del primer uso 10 Instalaci n poste de acero Permite montaje de 360 grados en poste T poste Y o similar 11 Puerto de recarga El...

Page 18: ...Es decir en el hemisferio norte el panel est orientado hacia el sur en el hemisferio sur el panel est orientado hacia el norte Evite colocarlo en una zona sombr a 5 Conecte los cables a Conecte el ter...

Page 19: ...controlar animales nocturnos Energ a m xima El energizador reduce los impulsos durante la noche para conservar energ a lo que le permite emitir impulsos m s altos durante el d a cuando los animales es...

Page 20: ...e suficiente sol Apague el energizador durante 3 d as d jelo al sol para cargar la bater a Conecte el Kit de Recarga G40110 para cargar la bater a El indicador de la bater a parpadea en rojo Bater a a...

Page 21: ...solar antenga labater a cargada Recargue la bater a antes y despu sdel almacenamiento Bater a libre de mantenimiento La bater a no debe abrirse y no requiere mantenimiento Reemplazo de la bater a Use...

Page 22: ...APAVE 9609185 001 1 B DESECHO DE COMPONENTES Y EQUIPOS ELECTR NICOS Este s mbolo en el producto indica que dicho producto embalaje y por sobre todo la bater a no debe ser desechado con otros desperdi...

Page 23: ...producto en internet en www gallagherams com y benef ciese de las siguientes ventajas Un servicio de atenci n al cliente y un soporte t cnico tiles Un registro que puede ser de ayuda si pierde o le r...

Page 24: ...SP CONDICIONES DE LA GARANT A Se garantiza este producto frente a defectos en el material o en la mano de obra durante un periodo de un a o a partir de la fecha en que el usuario final compr el produc...

Reviews: