Resistance
It is important to understand how the resistance
of different leadout wires can affect the
performance of your electric fence.
Resistance (Ohms) measures a wire’s ability to
conduct electricity (current). The lower the Ohms,
the more current it will conduct. It has the same
effect as the friction of a water pipe has on water
flow. Voltage in electricity is like pressure in water.
Electric current (amps) is like water volume or
flow.
4.4 Fence Construction
4.4.1 Install the leadout
The leadout cable is the power link
between the Energizer and the fence.
The leadout cable can be either run
overhead or underground.
Insulated leadout cable should be
used to prevent the leadout from
shorting out on obstructions or the
ground.
No Pressure
No Voltage
Small Pump
Small Pipe
Low pressure and volume, leaks, distance and friction
One Wire
Low voltage, vegetation leakage, distance and resistance
Low Power
Energizer
0.1 Joules
Low Pressure
Low Voltage
Large Pump
Small Pipe
High pressure, leaks, distance and friction
One Wire
High voltage, vegetation leakage, distance and resistance
High Power
Energizer
10 Joules
High Pressure
High Voltage
Large Pump
Large Pipe
High pressure and volume, leaks, distance but little friction
Several
Wires
High voltage and current, leakage and distance but little resistance
High Power
Energizer
10 Joules
Figure 4.12(a)
Figure 4.12(b)
Figure 4.12(c)