Minimum clearances from power lines for electric animal fences
Power line Voltage V
Clearance ft
Less than or equal to 1 000
10
Greater than 1 000 and less than or equal to 33 000
13
Greater than 33 000
26
• If
connec
Ɵ
ng leads and electric animal fence wires are installed near an overhead power line, their height
above the ground shall not exceed 10
Ō
.
This height applies either side of the orthogonal projec
Ɵ
on of the outermost conductors of the power
line on the ground surface, for a distance of:-
-
6
Ō
for power lines opera
Ɵ
ng at a nominal voltage not exceeding 1000V;
-
50
Ō
for power lines opera
Ɵ
ng at a nominal voltage exceeding 1000V.
•
Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.
•
Where an electric animal fence crosses a public pathway, a non-electri
Į
ed gate shall be incorporated
in the electric animal fence at that point or a crossing by means of s
Ɵ
les shall be provided. At any such
crossing, the adjacent electri
Į
ed wires shall carry warning signs (G6020).
•
Any part of an electric animal fence that is installed along a public road or pathway shall be iden
Ɵ
Į
ed by
electric fence warning signs (G6020) at regular intervals that are securely
fastened to the fence posts or
Į
rmly clamped to the fence wires.
•
The size of the warning sign shall be at least 4 inches x 8 inches.
•
The background color of both sides of the warning sign shall be yellow.
The inscrip
Ɵ
on on the sign shall be black and shall be either:
-
the substance of “CAUTION: Electric Fence” or,
-
the symbol shown:
• The
inscrip
Ɵ
on shall be indelible, inscribed on both sides of the warning
sign and have a height of at least 1 inch.
•
Ensure that all mains operated, ancillary equipment connected to the electric animal fence circuit
provides a degree of isola
Ɵ
on between the fence circuit and the supply mains equivalent to that provided
by the energizer.
• Protec
Ɵ
on from the weather shall be provided for the ancillary equipment unless this equipment is
cer
Ɵ
Į
ied by the manufacturer as being suitable for use outdoors and is of a type with a minimum degree
of protec
Ɵ
on IPX4.
WARNING: Risk of Electric Shock.
Do not connect the energizer simultaneously to a fence and to any
other device such as a ca
Ʃ
le trainer or a poultry trainer. Otherwise, lightning striking your fence will
be conducted to all other devices.
This energizer complies with interna
Ɵ
onal safety regula
Ɵ
ons and is manufactured to interna
Ɵ
onal standards.
Gallagher reserves the right to make changes without no
Ɵ
ce to any product speci
Į
ca
Ɵ
on to improve reliability,
func
Ɵ
on or design. E & OE.
The author thanks the Interna
Ɵ
onal Electrotechnical Commission (IEC) for permission to reproduce Informa
Ɵ
on from
its Interna
Ɵ
onal Publica
Ɵ
on 60335-2-76 ed.2.0 (2002). All such extracts are copyright of IEC, Geneva, Switzerland.
All rights reserved. Further informa
Ɵ
on on the IEC is available from www.iec.ch. IEC has no responsibility for the
placement and context in which the extracts and contents are reproduced by the author, nor is IEC in any way
responsible for the other content or accuracy therein
Save these instruc
Ɵ
ons
SERVICE OF DOUBLE-INSULATED APPLIANCES
In a double-insulated controller, two systems of insula
Ɵ
on are provided instead of grounding. No equipment
grounding means is provided in the supply cord of a double-insulated controller, nor should a means for
equipment grounding be added to the controller. Servicing a double-insulated controller requires extreme
care and knowledge of the system, and should be done only by quali
Į
ed service personnel. Replacement
parts of a double insulated controller must be iden
Ɵ
cal to the parts they replace. A double insulated
controller is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED”. The symbol for double
insula
Ɵ
on
may also be marked on the appliance.
To reduce the risk of electric shock, this fence controller has a polarized plug (one blade is wider than the
other). This plug will
Į
t in a polarized outlet only one way. If the plug does not
Į
t fully in the outlet, reverse
the plug. If it s
Ɵ
ll does not
Į
t, contact a quali
Į
ed electrician to install the proper outlet. Do not change the
plug in any way.
Summary of Contents for M150
Page 4: ......
Page 19: ......
Page 20: ...FENCE ENERGIZER M150 M200 M300 M600 M1000 Template Guide Plantilla...
Page 22: ......
Page 40: ...www gallagher com Gallagher Private Bag 3026 Hamilton New Zealand...