English
Gallagher 3E4451 M1100 M1500 Energizer User Manual
12
Fence Lead-out
Inadequate fence lead-out is o en the reason for poor voltage
on the fence. Par cularly on either larger fence systems or fence
systems heavily loaded with vegeta on.
Lead-out is defi ned as the wire system that takes the power from
the Energizer to the centre of the fence system - not just from
the Energizer to the fence! Basically, the more wires connected in
parallel, the be er the voltage at the end of the fence.
If the centre of the fence system is more than 100m (300 ) from the Energizer, at least
1 x 2.5mm wire is required. If the centre of the fence system is more than 1km (5/8 mile)
from the Energizer, a minimum of 3 x 2.5mm wires or a single High Conduc ve 2.5mm
“PowerWire” is required. Larger fence systems or heavily loaded fence systems with large
Energizers may require more wires to adequately transfer the power from the Energizer
onto the fence system.
HANDY HINT
PRDUCT SPECIFICATIONS
M1100
M1500
Stored Energy:
11 J
15 J
Output Energy:
8,5 J
11 J
Output Voltage (no load):
8,1 kV
8,1 kV
Ingress Protec on
IPX4
Dimensions : HxWxD
212 mm x 268 mm x 95 mm
Weight:
2,8 kg