background image

Page  1   

3E4288 Gallagher T10 Reader | Edition 1 | August 2016

 

Copyright © Gallagher Group Limited

Gallagher

 

T10 Reader

Installation Note

T10 Mifare Reader Black: C300400
T10 Mifare Reader White: C300401
T10 PIV Reader Black: C305400
T10 PIV Reader White: C305401

Summary of Contents for C300400

Page 1: ...0 Reader Edition 1 August 2016 Copyright Gallagher Group Limited Gallagher T10 Reader Installation Note T10 Mifare Reader Black C300400 T10 Mifare Reader White C300401 T10 PIV Reader Black C305400 T10...

Page 2: ...ess and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither Ga...

Page 3: ...2016 Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 4 3 Distance between readers 7 4 Installation 7 5 LED indications 9 6 Accessories 10 7 Technical specifications 10 8...

Page 4: ...s protocol to communicate with the Gallagher Controller IMPORTANT HBUS compatibility HBUS communications are supported with sites running Gallagher Command Centre vEL7 00 software or later IMPORTANT P...

Page 5: ...i e A T or Star topology should not be used between devices Should Star or Home Run wiring be required the HBUS 4H 8H Modules and the HBUS Door Module allow multiple HBUS devices to be individually wi...

Page 6: ...ELDEN 9842 shielded 2 twisted pair Each 2 x 0 2 mm2 24 AWG 500 m 1640 ft 200 m 650 ft 100 m 330 ft SEC472 4 x 0 2 mm2 Not twisted pairs 24 AWG 400 m 1310 ft 200 m 650 ft 100 m 330 ft SEC4142 4 x 0 4 m...

Page 7: ...tal surface The recommended mounting height for the reader is 1 1 m 3 6 ft from the floor level to the centre of the reader device However this may vary in some countries and you should check local re...

Page 8: ...oller 6000 A Cardax IV Reader connects to a Gallagher Controller 6000 Gallagher 4R 8R Module attached to a Controller 6000 Gallagher GBUS Universal Reader Interface Gallagher GBUS URI Gallagher Contro...

Page 9: ...teps 8 Configure the reader in Command Centre If the reader is connected as an HBUS Reader refer to the topic Configuring HBUS Devices in the Command Centre Configuration Client Online Help If the rea...

Page 10: ...0 7 Technical specifications Routine maintenance Not applicable for this reader Cleaning This reader should only be cleaned with a clean lint free damp cloth Voltage 9 Vdc 16 Vdc Current Idle 1 Maximu...

Page 11: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Page 12: ...gust 2016 Copyright Gallagher Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 115 mm 4 53 35 mm 1 38 44 mm 1 73 40 mm 1 57 13 mm 1 2...