Section 2 - 3
21-11-1008
2.0 Installation, continued
E.
Remove the 5/32” plug from the Valve Stack Port for slot two. Insert the free end
of the 5/32” O.D. green tube (item E) into this Port.
Remove the
“T” plug and
insert Item E.
F. Fill the Cylinder with a suitable, oxygen compatible detergent or cleaning
solution. The level of the detergent should be 6” below the bottom of the threads
in the Cylinder Neck. Use an oxygen compatible, liquid degreaser, water soluble
soap such as SD-13. SD-13 is available from Galiso, Incorporated at (800) 854-
3789 or visit the website at
NOTE: Certain types of detergents and cylinder cleaning solutions are not compatible
with aluminum cylinders. Galiso, Inc. recommends using a steel cylinder as the
Detergent Reservoir.
Put Teflon tape around the threads on the Probe and screw into the neck of the
Detergent Reservoir Cylinder.
G.
Install the Soap Probe (item F) into a clean, low pressure Cylinder with a ¾” NPT
neck opening. The bottom of the Dip Tube may need to be trimmed prior to
installation. The length of the Dip Tube should allow approximately 3” between
the end of the Dip tube and the bottom of the cylinder (after fully installed in the
Cylinder Neck).