ELECTRIC MAXIDOOR
®
Appendix 2: Optional Adjacent Drives
34 of 40
ENG
SB1
SA1
SH1
SG1
SF3
SE1
SD1
SC1
SJ2
SI1
2
1
9.5
Replacing Section 6.2: Fix the Ratchet (SA1) to the Ratchet Bracket
(SB1) with the M12 x 90mm bolt (SC1) provided. The standard fitting of the
ratchet bracket is depicted in Figure 30, but it can be reversed if vertical
mounting space is limited. Fit assembly to the building with three fixings,
minimum size 8mm.
Figure 30
9.6
Replacing Section 6.3: Referring to Figure 30. Fix vertical webbing
strap (SD1) to second strap down on the door using the Clamp Plates (SE1)
and M8 x 20 Bolts (SI1) provided. Repeat process on top strap but use the
M8 x 90 Bolts supplied (SJ2) and include the Wire Support Assembly (SF3),
Spacers (SH1) and Wire Support Protection Pad (SG1). Feed webbing
through ratchet and ensuring a minimum of 150mm of webbing is around the
ratchet barrel operate handle to lift the door. Continue to adjust ratchet until
top of door is level.
SD1
SE1
SJ2
SF3
SH1