GALAXY SPAS PH-015/R1U Tech Book Download Page 9

8

Installation

Precautions

•  Avoid locating the unit close to bedrooms or other noise sensitive areas.
•  Avoid a location which could create vibration (e.g. secured to a solid wall).
•  The fan should not blow towards windows, walls or spaces likely to be inhabited by people or animals.
•  Do not install where the Heat pump is likely to be subjected to polluted air, dust or debris, etc.
•  Avoid directing fan output against the dominant wind directions.
•  Protect the heat pump from possible snow fall.
•  Minimise exposure to environmental conditions as much as possible and never block the airflow.

Securing the Heat pump

The Heat pump should be securely fixed. The four included rubber mounts should be installed to absorb 
high-frequency vibrations.

Piping

A bypass, consisting of three valves, must be installed to adjust water flow to the Heat pump and to isolate the                        
apparatus for maintenance purpose.

For a more stable flow in the heat exchanger, it is recommended to install the Heat pump on the pressure side of the 

 

main pump.

If your installation is equipped with a water treatment system (chlorine, bromine, salt, etc.) the bypass must be installed 
before the water treatment, with a check valve between the bypass and water treatment system.

Condensation

The air drawn into the Heat pump is strongly cooled by the operation of the Heat pump for heating the spa water, which 
maycause condensation on the fins of the evaporator. The amount of water may be as much as several liters per hour  
at high relative humidity. This is sometimes mistakenly regarded as a water leak.

Since water generated by condensation will be evacuated at the bottom of the Heat pump, it is better to provide a slight 
rearward slope when installing the Heat pump to allow this water to flow freely on the ground.  It must also be ensured 
that this evacuation of water will not affect any components around the Heat pump like electrical circuit and material like  
wood ormetal that can be weakened by water That said, be aware that water will flow under the Heat pump in normal
operation.

spa circulation/ 

main pump

spa control

input valve

bypass valve

output valve

water in

water out

spa equipment bay

Heat pump

In order to limit the heat loss from the piping, 

it is recommended to install the heat pump as close 

as possible to the spa. A 16 foot (5 m) cord is provided.

communication port RS485

Power

Summary of Contents for PH-015/R1U

Page 1: ...TECHBOOK A new way to regulate the water of your spa HEAT PUMP plug and play solution benefit from energy savings a total flexibility that can also cool down water...

Page 2: ...1 Safety instructions 2 Warnings 3 Introduction 3 Overview 5 Heat pump overview 5 5 Connections 6 Installation 7 Operating modes 9 Maintenance 10 Steps to winterize your heat pump 11 Troubleshooting...

Page 3: ...AS THEY ARE SUFFICIENT SO THAT THE AMBIENT TEMPERATURE AROUND THE APPARATUS DOES NOT EXCEED 140 F 60 C ONLY USE ATTACHMENTS ACCESSORIES SPECIFIED BY THE MANUFACTURER REFER ALL SERVICING TO QUALIFIED S...

Page 4: ...he water of your spa Here comes new heat pump solution Using our Heat pump has never been so easy Simply connect it to a Y series control that supports it and you re good to go Are you looking for the...

Page 5: ...s Carbon Emissions Titanium heat exchanger The advanced titanium heat exchanger guarantees a longer life span free of corrosion It can be used with all types of water treatment including chlorine iodi...

Page 6: ...Heat pump dimensions PH 015 R1U PH 020 R1U PH 030 R1U A 570mm 602mm B C D E F G H A Connection box Fastening bracket B 746mm 956mm C 264mm 334mm D 305mm 375mm E 295mm 360mm F 395mm 545mm G 270mm 350m...

Page 7: ...accessories when the Heat pump or a different heat pump is not powered by the spa control set the heat pump current to zero 0 through your spa user interface Terminal box The terminal box is located...

Page 8: ...m the unit It is recommended to install the Heat pump away from any other home appliances to avoid the chance of electromagnetic interference Please refer to the Air space requirements section of this...

Page 9: ...chlorine bromine salt etc the bypass must be installed before the water treatment with a check valve between the bypass and water treatment system Condensation The air drawn into the Heat pump is stro...

Page 10: ...m both Smart Heat and Cool modes and has the ability to select the proper Heat or Cool mode automatically according to the water temperature The heating element is activated only if there is a large t...

Page 11: ...d condenser outflow should be clear of all obstructions leaves twigs etc before each new heating season These can be manually removed using compressed air or by flushing with clean water It may be nec...

Page 12: ...If a protection kicks in or if an error is detected in the heat pump an error code will be reported on the spa keypad If more than one error is detected only the error with the highest priority will b...

Reviews: