Galanz XQG60-U108E After-Sales Service Manual Download Page 43

                                                                    XYJGT6070UDE-002   

42 

 

 

 

 

 

1

、从扣位

1

2

中取

出进水斗组件

 

Take the inlet 

housing out of the 

buckle 1 and 2 

 

2

、抬起进水斗组件,

把进水软管挂钩往
上提,直到脱出扣位
为止(见左图一)

 

Lift the inlet housing 

and lift the inlet 

hose hook up until it 

is out of the buckle 

position (see fig.1 

on the left) 

 

3

、握住进水软管,

用力往下拉(见左图
二)

 

Hold the inlet hose 

and pull down hard 

(see fig.2 on the 

left) 

 

4

、拆出的进水阀、

进水斗组件取出并
做好防护

 

Take out and 

protect water valve 

and inlet housing 

 

拆除发热管和电机线组

 

Remove the harness of heater and motor 

图一

 

fig.1 

图二

 

fig.2 

Summary of Contents for XQG60-U108E

Page 1: ...After sales Service manual XQG60 U108E XQG70 U112U Zhongshan Galanz Consumer Electric Appliances Co Ltd Automatic Drum Washing Machine...

Page 2: ...atus description 9 5 2 2 Program function list 10 5 2 3 Button function 12 5 3 Special Functions 15 5 3 1 Automatic power off 15 5 3 2 Balance 16 5 3 3 Temp 16 5 3 4 Rinse 16 5 3 5 Delay 16 5 3 6 Spee...

Page 3: ...U112U Brand Galanz Mixed 40 Mixed 40 Super Quick 20 40 60 Eco 40 60 Anti Allergy 30 Down 30 Synthetics 40 Synthetics 40 Delicates Silk 30 Woolens 30 Drum Clean 60 Drum Clean 60 Rinse Spin Spin Anti B...

Page 4: ...g Washing drive method Universal motor belt Spinning drive method Universal motor belt Water level detection method Water level sensor Belt 8 ribs 5 ribs Inner drum size 241 7 506mm W D H Pack dimensi...

Page 5: ...ean 60 0kg Rinse Spin Spin Anti Bac 3 5kg Note The number means the washing capacity of the program means no such program 2 4 Main Components Specifications Model XQG60 U108E XQG70 U112U Component nam...

Page 6: ...XYJGT6070UDE 002 5 Temperature sensor R 25 12k Resistance R 25 12k Options switch Touch Interlock switch 250V 16 6 A Water valve 220V 240V 50Hz 60Hz XQG70 U112U XQG60 U108E...

Page 7: ...XYJGT6070UDE 002 6 3 Circuit Diagram XQG60 U108E...

Page 8: ...ructure 4 1 Structure Diagram See assembling drawing 4 2 Water Line System Water inflow Inlet pipe Water valve Inlet valve hose Inlet housing Outer drum Drain Outer drum Drain hose Drain pump Drain ho...

Page 9: ...XYJGT6070UDE 002 8 Water valve Inlet valve hose Inlet housing Drain pump Drain hose Drain hose Outer drum...

Page 10: ...no power input 2 Off Turn off all load outputs turn off display outputs only the Power key responds 3 Standby In the standby state the default function parameter settings are displayed and the paramet...

Page 11: ...corresponding fault code 8 Maintenance mode For plant testing or failure judgment 5 2 2 Program function list Program General function Additional function Automatic power off Temp Rinse Delay XQG60 U1...

Page 12: ...Program Additional function Speed Child lock Midway add clothes XQG70 U112U XQG60 U108E XQG70 U112U XQG60 U108E XQG70 U112U Mixed Mixed 40 Super Quick 20 40 60 Eco 40 60 Anti Allergy 30 Down 30 Synthe...

Page 13: ...use Rinse Delay Select and Anti Bac There are 7 commonly used buttons NO Product state Buttons Operation and Display 1 Off Power Press to power on Other options The key is invalid and the display is o...

Page 14: ...e Delay No response Select Change the running program Anti Bac Select the Anti Bac program 5 Delay Power 3 Long press for 3 seconds to power off Start Pause Delay start or pause Rinse The rinsing time...

Page 15: ...s to power off Start Pause The selected program starts immediately Rinse Select the rinse times Delay Select the program appointment time Speed Select the spin speed Temp Select the wash temperature P...

Page 16: ...when the appointment is suspended Speed The dehydration speed can be selected when the appointment is suspended Temp The washing temperature can be selected when the appointment is suspended Program T...

Page 17: ...f after about 20 minutes the laundry is still not evenly distributed in the drum the machine will not spin In this case redistributed the load manually and reselect the spin program 5 3 3 Temp XQG70 U...

Page 18: ...a few seconds and the light under the icon is lighting then the function works Press the same buttons a few seconds to cancel this function When the function works all buttons are not available 5 3 8...

Page 19: ...ds 2 K4 t02 Ert NEr Press the K4 key the display screen displays t02 press the Start Pause button to enter the test program the display screen displays Ert Press the Start Pause button to display the...

Page 20: ...the display cycle alternately 3 000 In the formal product stage the software version information is displayed from 000 4 K4 PC Press K4 again the display screen will display PC and then switch to the...

Page 21: ...orward rotation setting time C07 P08 C07 outer cylinder leakage test P08 position WL00 WL00 Judge whether the water level is above WL00 level If not make up water to WL00 level by softening valve then...

Page 22: ...l give an alarm All testing stages can be carried out In this mode if the selected program is not in the above test position there is no response Press the Power button to exit this mode 7 Abnormality...

Page 23: ...assembly of water level sensor and hose air or change it Turn off the power 4 The connection between the water level sensor and wire is not secure or wire is damaged 4 Check the connection and ensure...

Page 24: ...t 2 Door lock is damaged 2 Change the door lock Turn off the power 3 The connection between the door lock and wire is not secure or wire is damaged 3 Check the connection and ensure it is secure or ch...

Page 25: ...reset 3 The drain pump is damaged 3 Change the drain pump Turn off the power 4 The connection between the drain pump and wire is not secure or wire is damaged 4 Check the connection and ensure it is...

Page 26: ...lock close all loads drain to the empty cylinder water level for setting time 2 Close the drain pump to maintain the water level detection when the overflow level is detected again repeat the above p...

Page 27: ...ure or wire is damaged 1 Check the connection and ensure it is secure or change wire Close the door lock close all loads and drain to a safe level for setting time Turn off the power 2 The motor is pr...

Page 28: ...door lock and close all loads undrained Turn off the power 2 The heating tube is damaged 2 Change the heating tube 2 99 E7 Water heating temperature sensor exceeds 99 but E7 error is not reported 3 Th...

Page 29: ...XYJGT6070UDE 002 28 2 The temperature sensor is damaged 2 Change the temperature sensor 3 The PCB is damaged 3 Change the PCB 8 Exploded View XQG70 U112U Take XQG70 U112U for example...

Page 30: ...XYJGT6070UDE 002 29...

Page 31: ...XYJGT6070UDE 002 30...

Page 32: ...2 1 1039 Top Cover 1 3 XU1QG70U 3 1039 Control Panel Component As 1 4 XU1QG70E 4 1039 Door Component As 1 5 XU1QG70 5 1039 Inlet House Component As 1 6 XU1QG70 6 1039 Drum Component As 1 7 XLD03 18 T...

Page 33: ...Control Panel 1 3 2 XU1QG70 3 2 1039 PCB House 1 3 3 XU1QG70 3 3 1039 Light Guide 1 3 4 XU1QG70 3 5 1040 Display 1 3 5 XU1QG70U 3 4 1039 PCB 1 4 1 XU1QG70 4 1 1039 Outer Door Frame 1 4 2 XA1QG72D 5 5...

Page 34: ...2 Motor 1 6 10 X1QG60 7 3 6 Rubber Ring1 1 6 6 11 XLD03 15 Motor Bolt As 2 6 12 XT5QG90 7 3 2 584 Heater Support 1 6 13 XA2QG60 8 3 167 Heater 1 6 14 XA8QG80 7 1 975 Belt 1 6 15 XU1QG70 6 1 1039 Gaske...

Page 35: ...for these 4 parts and die cast them before use 9 Machine Disassembling Procedures 9 1 Using Tools NO Name Sketch Map 1 Cross screwdriver or Electric screwdriver or and 2 10 Electric screwdriver and N...

Page 36: ...1 2 Note 1 When removing sheet metal parts please wear gloves and protect them to avoid injury 2 When assembling all parts please assemble them according to the original condition 9 2 Disassembly Proc...

Page 37: ...six screws 3 4 5 6 7 and 8 of the back cover with a cross screwdriver 1 The top cover as and back cover removed shall be protected against scratching Remove control panel as 1 Pull out the drawer pres...

Page 38: ...gure 5 Pull out all terminals on the PCB arrange wiring harness 6 After removing the panel components make anti static and anti scratch protection 1 When using the diagonal cutters be careful not to c...

Page 39: ...d 6 shown in the figure with a cross screwdriver and take out the upper frame 2 Pay attention to the scraping hand when taking out the upper frame 1 The upper frame is sharp It is recommended to wear...

Page 40: ...door 3 3 Stretch the door seal 3 by hand take out the outer gasket clamp and arrange the outer gasket clamp into the front panel 1 The removed door shall be protected against scratch 2 When removing...

Page 41: ...Use the cross screwdriver to exit the five screws 3 4 5 6 and 7 in the left figure 1 Don t scratch the front panel when removing the screw 2 Pay attention to take out the front panel do not force too...

Page 42: ...s screwdriver and take out the water valve 1 1 2 Pay attention to the sequence of water valve terminal 1 and 2 on the original machine Do not connect wrong terminals during reinstallation 2 3 4 Pay at...

Page 43: ...the inlet housing and lift the inlet hose hook up until it is out of the buckle position see fig 1 on the left 3 Hold the inlet hose and pull down hard see fig 2 on the left 4 Take out and protect wat...

Page 44: ...e heater and motor wire group 2 3 4 5 and 6 on the back cover of the rear tub 1 When using the diagonal cutters be careful not to cut the thread 2 Pay attention not to break the wire when pulling out...

Page 45: ...screwdriver and take out the balancer 2 Remove the upper balancer to be handled gently to avoid damage 3 3 Pull out the water level switch terminal 3 move the water level sensor upward and remove the...

Page 46: ...3 with combination pliers and pull it out 2 16 1 2 Remove the bolts 1 and 2 with No 16 outer hexagon sleeve and electric screwdriver Remove tub as 1 2 3 Combination pliers Using tools Using tools 16 N...

Page 47: ...abinet Pay attention not to press the line or touch other materials during the lifting of the tub 1 When lifting the tub avoid touching the harness water level switch cabinet filter or rubber parts 2...

Page 48: ...ver 3 8 Clamp the hose clamp 8 with combination pliers and pull out the drain hose with force at the same time 1 When removing or installing the drain pump screws please pay attention to avoid sliding...

Page 49: ...ion pliers and rotate it 90 degrees then take out the power cord 1 1 2 3 4 1 2 3 4 The sequence of line groups of position 1 2 3 and 4 on the filter 1 single power line is brown 2 one thick and one th...

Page 50: ...ve rubber sleeve 3 Lift the motor up with both hands and take out the motor 4 10 3 Remove the nut 3 of the fixed heating pipe with 10 outer hexagon sleeve and electric screwdriver and then take out th...

Reviews: