11
Set lamp:
1.
In standby mode, press and hold PROG button until the the display shows "PROG", " ", " "
and " ".
2.
Press and hold number button 2 more than 3 seconds, and repeatedly the operation to cycle select
"LA1"and "LA2".
Code
Function
LA1
Open the door, lamp is on. Close the door, lamp is off
LA2
Open the door, lamp is off. Close the door, lamp is on
NOTE:
After setting up, press STOP button or no operation within 20 seconds, the system will return to
standby mode and the display will show "0".
Set buzzer scale:
1.
In standby mode, press and hold PROG button until the the display shows "PROG", " ", " "
and " ".
2.
Press and hold number button 3 more than 3 seconds, and repeatedly the operation to cycle select
"b F1", "b F2" or "b F3".
Code
Frequency
b F1
2 KHz
b F2
1 KHz
b F3
675 Hz
NOTE:
After setting up, press STOP button or no operation within 20 seconds, the system will return to
standby mode and the display will show "0".
Set power saving mode:
1.
In standby mode, press and hold PROG button until the the display shows "PROG", " ", " "
and " ".
2.
Press and hold POWER button more than 3 seconds, and repeatedly the operation to cycle select
"Po1", "Po2", "Po3" and "Po4".
Code
The delay time of entering mode
Po1
1 minute
Po2
2 minutes
Po3
3 minutes
Po4
Off power saving mode
NOTE:
After setting up, press STOP button or no operation within 20 seconds, the system will return to
standby mode and the display will show "0".
Restore factory settings:
1.
In standby mode, press and hold PROG button until the the display shows "PROG", " ", " "
and " ".
2.
Press and hold START and PROG buttons at the same time more than 3 seconds, the display will
show "0 0", the factory settings have been restored
NOTE:
After setting up, if press STOP button or no operation within 20 seconds, the system will return to