WARNING
ELECTRIC SHOCK HAZARD
The electrical power to the oven branch circuit
must be shut off while line connections are
being made.
Do not
use an extension cord
with this appliance. Electrical ground is required
on this appliance. The free end of the green
wire (the ground wire) must be connected to a
suitable ground. This wire must remain
grounded to the oven.
If cold water pipe is interrupted by plastic, non
metallic gaskets, union connections or other
insulating materials
.
Do not
use for grounding.
Do not
ground to a gas pipe.
Do not
have
a fuse in the
neutral
or
grounding
circuit. A
fuse in the
neutral
or
grounding
circuit could
result in an electric shock.
Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded. Failure to do so could result in death,
fire or electric shock.
Electrical Connection
To properly install your oven, you must determine the type of electrical
connection you will be using and follow the instructions provided for it
here.
•
Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial
number rating label.
All models are dual rated, and designed to be connected to either
208/240V AC, 60Hz, 3-wire or 4-wire, two-phase power supply.
•
The electrical supply should be a 3-wire or 4-wire, two-phase AC.
Install a suitable conduit box (not furnished).
An appropriately sized, UL conduit connector must be used to
correctly attach the conduit to the junction box.
IMPORTANT:
Local Codes may vary; installation electrical connections
and grounding must comply with all applicable local codes.
If local codes permit grounding through the electrical supply neutral,
connect both the white neutral wire and the green ground wire from
the oven to the white neutral electrical supply wire.
Circuit Required
208V, 60 Hz
240V, 60 Hz
12 Amp
15 Amp