Galactron MK 2250 Owner'S Manual Download Page 7

 

When you press one of the volume control buttons on the remote control, the front panel will illuminate on 
and  the  arrow  that  indicates  whether  the  level  is  climbing  or  descending.  Arriving  at  the  maximum 
attenuation  or  maximum  exaltation  written  and  arrows  do  not  light  up  anymore,  indicating  that  they  have 
been reached the limits of adjustment. 
 
Press "MUTING", when pressed on the remote, due to the lowering of instantaneous output level of 20 dB. 
      To return to the original level is sufficient to press the switch. 
 

TURNING OFF THE AMPLIFIER 
 

To put the amplifier in STAND-BY, and just press on the remote control simultaneously the keys (+ / -). 
 
To turn off the amplifier you must first press the right button on the front panel and then subsequently lead to 
the OFF position the switch on the rear panel. The microprocessor control provides first a short circuit by the 
output signal from the preamplifier, so as to prevent impulsive noise, then deactivates the relay that supplies 
power to the power supply main: at this point all the lights on the panel are turned off. 
 
 

WARNING:  NEVER  TURN  OFF  THE  AMPLIFIER  WITH    THE  MAIN  LINE  SUPPLY  POWER 
SWITCH  BEFORE  HAVING  PLACED  THE  UNIT  IN  STAND-BY.  THIS  ERRONEUS 
PROCEDURE  WILL  CAUSE  VIOLENT  TRANSIENT  AT  THE  AMPLIFIER  OUTPUT,  WITH 
POTENTIALLY DANGEROUS EFFECTS ON THE SPEAKERS. 

 
 

 

TROUBLESHOOTING 

 

The main power switch is turned on, but the POWER LED is not illuminated. 
The wall outlet is not powered. 

 

Check that the correct voltage is presents at the end of the power cord.   If 

the mains supply voltage is supplied to the machine 

The fuse to the microprocessor has blown*. 
 

Turn  off  the  amplifier,  disconnect  the  cord  from  the  wall  socket, 

 

remove the fuse from its holder and check for continuity. 

 

If the fuse is in good condition, 

 

The POWER LED is burned out 

 

Try  to  activate  the  amplifier  using  the  remote  control.  If  there  is  not 

 

action, 

The microprocessor has failed. 

 

The POWER LED is illuminated but the amplifier does not respond to the remote control. 
 

The  infrared  detector  on  the  amplifier  is  obstructed,  or  it  is  placed  at  an 

 

angle greater than 30° with respect to the remote control. 

 

Check that the amplifier is in correct position. 

 

If the amplifier is in the correct position, 

The batteries in the remote control unit are dead. 
 

Check the battery charge level, and replace as required. 

 

If the battery are charged, 

The remote control unit has malfunctioned. 
 

Try  setting  the  amplifier  with  another  remote  control  of  the  same 

 

type. 

 

If the unit still does not work properly, 

the infrared detector has failed. 
The amplifier goes ON normally, but no sound is produced by the speakers. 
The program source is not connected correctly. 

 

Check  that  the  input  selected  is  correctly  connected  to  the  audio 

 

source. 

 

If the connections are correct, 

The source is not functioning properly, 
 

Check that a correct signal is output by the source. 

 

If the output signal is correct, 

The cable are bad. 
 

Check the electrical continuity of the cables and jacks. 

Summary of Contents for MK 2250

Page 1: ...1 Owner s Manual MK 2250...

Page 2: ...t rather the tradition of excellence appeal and style associated with our name earned in over the span of our history a name is now almost a legend We have worked hard to perfect this technology and b...

Page 3: ...the rear panel of the amplifier see the Chapter on Connections and Checks make sure the main power switch is in the OFF position top down switch in the ON position switch in the OFF position The ampli...

Page 4: ...g the L1 button on the remote control You can connect any equipment with a rated output greater than 400 mV Only MK 2280 and MK 2225 balanced line input XLR connectors 6 L2 INPUT Unbalanced line input...

Page 5: ...ou require INFRA RED DETECTOR All commands to the amplifier are communicated via this sensor The infra red detector should be kept free of obstruction and the front of the amplifier should face toward...

Page 6: ...connected to the network the primary winding of the power transformer primary In this situation the LED POWER lights red To turn the amplifier simply press the Power button on the front panel to the...

Page 7: ...R LED is not illuminated The wall outlet is not powered Check that the correct voltage is presents at the end of the power cord If the mains supply voltage is supplied to the machine The fuse to the m...

Page 8: ...he external 3 5 A or 7 A main fuse Have the internal fuses checked by a suitable Service Station After being turned on with the power switch the amplifier goes in stand by and then goes On automatical...

Page 9: ...you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate handling of this product as unsorted municipal waste The recy...

Page 10: ...cient to constitute a risk of electric shock Appears on the unit to indicate important instructions for use or maintenance instructions in the accompanying literature Appears on the unit to indicate c...

Reviews: