We recommend that this air-conditioner be installed properly by qualified installation technicians in accordance 
with the installation instructions provided with the unit. 
Before installation, check if the voltage of the power supply in your home or office is the same as the voltage 
shown on the nameplate. 

You must not carry on any transformation to this product, otherwise, it may possibly 
cause such consequences as the water leakage, the breakdown, the short-circuit, an 
electric shock, fire, etc.
The work such as tube line welding, etc. should be carried out far away from the 
flammable explosive material vessels, including the air-conditioner refrigerant, to 
guarantee the security of the site.
To protect the air-conditioner from heavy corrosion, avoid installing the outdoor unit 
where salty seawater can splash directly onto it or in sulphurous air near a spa. Do 
not install the air-conditioner where excessively high heat-generating objects are 
placed. 

Never use gasoline or other inflammable gas near the air-conditioner, which is very 
dangerous. 

Do not turn the air-conditioner on and off from the power main switch. Use the 
ON/OFF operation button.
Do not stick anything into the air inlet and air outlet of both the indoor and outdoor 
units. This is dangerous because the fan is rotating at a high speed. 
Do not cool or heat the room too much if babies or invalids are present. 

CAUTION Statements

1

DANGER

WARNING

Read this manual carefully before using this air-conditioner. If you still have any 
difficulties or problems, consult your dealer for help. 
The air-conditioner is designed to provide you with comfortable room conditions. Use 
this unit only for its intended purpose as described in this instruction manual.

WARNING

CAUTION

If the supply cord is damaged, it must be replaced by the factory or its service department 
in case of danger.
The place where this product is installed must have the reliable electrical earth facility 
and the equipment. Please do not connect the grounding of this product to various kinds 
of air-feeding tube lines, the drain lines, the lightning protection facility as well as other 
tube lines to avoid receiving an electric shock and damages caused by other factors.
Wiring must be done by a qualified electrician. All the wiring must comply with the local 
electrical codes. 
Consider the capacity of the electric current of your electrical kilowatt-hour meter wires 
and socket before installation. 
The power wire where this product is installed is supposed to have the independent 
leakage protective device and the electric current over-load protection device which are 
provided for this product.
This appliance  is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning use of the appliance by a person 
responsible for their safety. 
Children should be supervised to ensure that they do not play with the appliance.
Means for disconnection, which can provide full disconnection in all poles, must be 
incorporated in the fixed wiring in accordance with the wiring rules .

Summary of Contents for GDZ18H-S

Page 1: ...nditioner Please read this carefully before installing and using this appliance and keep this manual for future reference use and installation instructions GDZ18H S GCZ18H S GDZ24H S GCZ24H S GDZ36H S...

Page 2: ...lly turn the unit on or off within a 24 hour period Save Installation Space Mute Operation The excellent fan design enable the airflow to be quiet and smooth with minimum noise Meeting Various Install...

Page 3: ...oner 2 Special Remarks 3 Troubleshooting 3 Diagram of Refrigerant Cycle Wiring 1 Refrigerant Flow Diagram 4 2 Electrical Wiring Diagram 4 Installation and Maintenance 1 Safety Notice 5 2 The Tools and...

Page 4: ...r If you still have any difficulties or problems consult your dealer for help The air conditioner is designed to provide you with comfortable room conditions Use this unit only for its intended purpos...

Page 5: ...r It is used for controlling power ON OFF setting the running mode temperature fan speed and other functions There are different types of remote controllers can be selected Operate instruction will be...

Page 6: ...es a high enough temperature That is because cold air prevention system is operating When the outdoor temperature is too low frost or ice may form in the outdoor heat exchanger reducing heating perfor...

Page 7: ...y valve Heat exchanger Liquid piping Heating cycle Cooling cycle INDOOR UNIT OUTDOOR UNIT Heat exchanger EEV Service valve Outdoor unit Outdoor unit Indoor unit Indoor unit Terminal Terminal Power sup...

Page 8: ...ep the refrigerant circuit free from substances other than the specified refrigerant such as air Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure r...

Page 9: ...mer Churn drill Knife or wire stripper Tube expander Inner hexagon spanner Tape measure 3 1 The Initial Check When moving the unit during or after unpacking make sure to lift it by holding its lifting...

Page 10: ...t least 1 meter away from televisions and radio this prevents image interference and noise in electrical appliances Noise may be generated depending on the conditions under which the electric wave is...

Page 11: ...ension to prevent the nuts from loosening 1 During the installation please cover the unit with the plastic cloth to keep it clean 2 Make sure the unit is installed level using a level or a plastic tub...

Page 12: ...Fig 4 1 The connection positions of the tube Fig 4 2 The pipe diameter The refrigerant gas pipe The refrigerant liquid pipe 2 As shown in Fig 4 3 screw up the nuts with 2 spanners Fig 4 3 Screw up th...

Page 13: ...hould be insulated because condensation may form there causing water to leak Drain piping passing indoors Drain sockets Referring the figure below insulate the drain socket and drain hose using the in...

Page 14: ...Air outlet The lid of the control box Remove the screws on the control box 11 Installation and Maintenance WARNING Fig 6 1 6 Electrical Wiring When clamping the wiring use the included clamping mater...

Page 15: ...inking Select desired parameter code 10 by pressing button and press ENTER button to confirm Select desired function code to rewrite the parameter values by pressing button and press ENTER button to c...

Page 16: ...Min 5cm Min 40cm Fig 7 1 Concrete base or alike Min 10cm Setscrew at least 4 About 40cm About 10cm Fig 7 2 7 2 Installation of the Outdoor Unit Firstly select the installation site and fix the outdoo...

Page 17: ...le to the wall using one clamp approx every 120 cm 8 5 Finishing the installation After completion of wrapping and insulation seal the hole on the wall with suitable sealant against wind and rain To a...

Page 18: ...at the joints of the indoor unit Straighten the connecting tubes and make them flush and fixed to the wall Seal the space around the hole in the wall through which the tubes come out with gypsum 9 4 T...

Page 19: ...onnecting the terminal block using flexible cord make sure to use the round crimp style terminal for connection to the power supply terminal block Place the round crimp style terminals on the wires up...

Page 20: ...EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device...

Reviews: