background image

 

SMART 400 MMA 

 14 

 

 

4. MAINTENANCE OPERATIONS. RECOMMENDATIONS. 

 

In order for the equipment to have a long life we 

must  follow  some  essential  rules  for  maintenance 
and use. Abide by these recommendations. 

 

CORRECT MAINTENANCE OF THE EQUIPMENT 

WILL AVOID A GREAT PERCENTAGE OF FAULTS. 

 

4.1 MACHINE MAINTENANCE. GENERAL 
RECOMMENDATIONS.

 

Before carrying out any operation on the machine 

or  welding  cables,  we  must  place  the switch of the 
equipment in "O" position of machine disconnected. 

Specialized personnel must handle the machine to 

carry out maintenance and repair operations

.

 

 

A-

 

 BLOW THE INSIDE OF THE MACHINE 
WITH COMPRESSED AIR FROM TIME TO 
TIME. 

 

 

The  accumulation  of  metal  dust  on  the  inside  is 

one of the main causes of breakdowns in this type 
of equipment as they are subject to a great amount 
of pollution. As an essential measure, the equipment 
must  be  kept  separate from the welding place, not 
placing  it  a  short  distance  away.  Keeping  the 
machine clean and dry is essential. The inside must 
be blown as required. We must avoid any anomaly 
or  deterioration  due  to  the  accumulation  of  dust. 
Blow  the  inside  of  the  equipment  with  clean  dry 
compressed  air.  As  routine  to  guarantee  that  the 
equipment  works  correctly,  check  that  once  the 
machine  has  been  blown the electrical connections 
are still properly tightened. 
 

WARNING!: SEPARATE THE MACHINE 

SUFFICIENTLY FROM THE WORKSTATION.   

PREVENT METAL DUST ENTERING THE 

EQUIPMENT. 

 

B-

 

 LOCATE THE EQUIPMENT IN A PLACE 
WHERE CLEAN AIR IS CONSTANTLY 
REPLACED. 

 

 

The machine ventilations must be kept free. It must 

be located in a place where clean air is renewed. 
 

C-

 

 THE MACHINE MUST ALWAYS BE 
OPERATED WITH THE HOUSING ON.  

 

D-

 

 DO NOT DISCONNECT THE MACHINE IF 
IT IS HOT.  

 

 

If you have finished the work do not disconnect the 

machine  immediately,  wait  until  the  inner  cooling 
system has totally cooled it. 
 

E-

 

KEEP THE WELDING ACCESSORIES IN 
GOOD CONDITIONS FOR USE. 

 

F-

 

ONCE THE WELDING OPERATION HAS 
FINISHED AVOID DIRECT CONTACT OF 
THE ELECTRODE-HOLDER CLAMP WITH 
THE WELDING EARTH CLAMP AND THE 
OTHER PARTS CONNECTED TO IT. 

 

4.2 RECOMMENDATIONS FOR REDUCING 
ELECTROMAGNETIC COMPATIBILITY (CEM) PROBLEMS.  

 

The user is responsible for the installation and use 

of the welding material according to the instructions 
in this manual and the following recommendations. 

 

Before  installing  the  welding  material,  the 

presence  of  the  following  in  the  surrounding  area 
must be kept in mind: 

 

 

Wiring  for  power,  control,  signalling,  and 
telephones. 

 

Radio and television receivers and transmitters. 

 

Computers and other control equipment. 

 

Critical security equipment. 

 

People with pace makers or hearing aids. 

 

Measurement and calibration equipment. 

 

 In  order  to  reduce  EMC problems, keep in mind 

the time of day when welding or other activities will 
be  carried  out.  Move  possible  interference  victims 
away from the welding installation. 

 

ALWAYS CONNECT THE MACHINE TO POWER 

USING AN EFFICIENT EARTH TAP. 

 

IF PROTECTIVE DEVICES OR SUPPLEMENTARY 

ELECTRICAL SYSTEM FILTERS ARE NEEDED, 

CONSULT OUR TECHNICAL SERVICE. 

 

PERFORM THE MAINTENANCE OPERATIONS 

DESCRIBED IN THIS MANUAL. 

 

USE THE SHORTEST WELDING WIRES POSSIBLE 

AND KEEP THEM PLACED NEXT TO EACH OTHER 

NEAR THE FLOOR.

 

 

 IF THE WELDING PIECE IS GROUNDED, KEEP IN 

MIND OPERATOR SAFETY AND NATIONAL 

REGULATIONS

.

 

Summary of Contents for Smart 400 MMA

Page 1: ...00V 50 60Hz ES ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL EN THIS EQUIPMENT MUST BE USED BY PROFESSIONALS TO HELP YOU IN YOUR WORK CAREFULLY READ THIS MANUAL FR CE POSTE À SOUDER DOIT ÊTRE UTILISÉ PAR DES PROFESSIONNELS POUR OBTENIR UN RÉSULTAT OPTIMUM LIRE ATTENTIVEMENT CE MANUEL Ref M 223000400E_ V 0 Jaime Ferrán 19 50014 ZARAGOZA SPAI...

Page 2: ...TER 3 START UP ADJUSTMENT AND OPERATION CONTROLS Page 12 CHAPTER 4 MAINTENANCE OPERATIONS RECOMMENDATIONS Page 14 CHAPTER 5 ANOMALIES PROBABLE CAUSES POSSIBLE SOLUTIONS Page 15 CHAPTER 6 SAFETY MEASURES Page 16 APPENDICES Page 24 DECLARATION OF CONFORMITY EC MARKING ELECTRICAL DRAWINGS DETAIL DRAWINGS AND REFERENCE LISTS FR TABLE DES MATIÈRES CHAPITRE 1 DESCRIPTION GÉNÉRALE CARACTÉRISTIQUES TECHNI...

Page 3: ...a sold I2max Factor de marcha 40 ºC 400 A 60 Intensidad nominal de soldadura X 100 I2n 40 ºC 310 A Función protección de soldadir VRD Función de Ayuda al cebado HOT START AJUSTABLE Función de Fuerza de arco ARC FORCE AJUSTABLE Función de Antipegado ANTISTICKING T I G Margen de regulación continua TIG I2min I2max 30 400 A Intensidad máxima sold I2max Factor de marcha 40 ºC 400 A 60 Intensidad nomin...

Page 4: ...este aparato es la de proteger a las personas de contactos directos o indirectos con partes eléctricas bajo tensión El interruptor diferencial se selecciona atendiendo a la Placa de características INTERRUPTOR AUTOMÁTICO IA Tripolar El aparato se elegirá de acuerdo con la Placa de características La conexión a la red se realiza mediante la manguera de entrada IMPORTANTE Compruebe que el cable está...

Page 5: ...RODO En este modo de trabajo dispondrá de las funciones de AYUDA AL CEBADO FUERZA DE ARCO y ANTIPEGADO Con ellas la soldadura de electrodos resulta más fácil y efectiva Selector de proceso de soldadura MODO TIG Este modo de trabajo es el ideal para la soldadura TIG Permite el cebado manual a contacto estableciendo un nivel bajo de corriente en el momento en el que el electrodo toca la pieza cebado...

Page 6: ...lo positivo y la masa al negativo En cada caso atenderemos a las indicaciones realizadas por el fabricante de electrodos En la figura se dibuja la preparación del equipo para este modo de trabajo en este caso observe que la polaridad de uso es inversa es decir la pinza de soldadura va colocada a polo positivo G F Selector de proceso de soldadura C MODO ELECTRODO En este modo de trabajo dispondrá d...

Page 7: ...debe ubicarse en un emplazamiento donde exista renovación de aire LA MAQUINA DEBE FUNCIONAR SIEMPRE CON LA ENVOLVENTE PUESTA NO DESCONECTE LA MAQUINA SI ESTA SE ENCUENTRA CALIENTE Si ha acabado el trabajo no desconecte inmediatamente la máquina espere a que el sistema de refrigeración interior la enfríe totalmente MANTENGA EN BUENAS CONDICIONES DE USO LOS ACCESORIOS DE SOLDADURA UNA VEZ FINALIZADA...

Page 8: ...do Equipo sobrecalentado espere a que el equipo se enfríe Posible avería en circuito de potencia SE QUEMA EL ELECTRODO EN SOLDADURA TIG Intensidad de soldadura excesiva para un determinado electrodo Disminuir corriente de soldadura o cambiar el electrodo por uno de mayor diámetro Utilización de polaridad inversa Colocar el electrodo al polo negativo Falta de gas de protección Regular a un caudal a...

Page 9: ...solventes dado que estas pueden descomponerse en el proceso de soldadura desprendiendo un humo que puede ser muy tóxico Esto mismo puede suceder con aquellos materiales que incorporen algún tipo de tratamiento superficial cincado galvanizado etc Evítese en todo momento la inhalación de los humos desprendidos en el proceso Protéjase del humo y polvo metálico que pueda originarse Utilice máscaras an...

Page 10: ... adjustment margin I2min I2max 30 400 A Maximum welding intensity I2max Duty cycle 40º C 400 A 60 Rated welding intensity X 100 I2n 40º C 310A HOT START function Arc striking aid ADJUSTABLE ARC FORCE function ARC FORCE ADJUSTABLE Antisticking function ANTISTICKING T I G TIG continuous adjustment margin I2min I2max 30 400 A Maximum welding intensity I2max Duty cycle 40º C 400 A 60 Rated welding int...

Page 11: ...t with live electrical parts The differential switch is selected on the basis of the type plate AUTOMATIC CIRCUIT BREAKER IA Tripolar The device will be selected according to the type plate The connection to the mains is made by the input hose IMPORTANT Verify that the wire is connected to a plug with an efficient earth tap If you have special equipment with power supply voltage other than 230 V y...

Page 12: ...In this mode the HOT START ARC FORCE and ANTI STICKING functions will be available Electrode welding is easier and more effective using these WELDING PROCESS SELECTOR TIG MODE This work mode is ideal for TIG welding It allows striking while establishing low currents when the electrode touches the piece LIFT ARC thus avoiding contamination of the piece and the electrode The electrode anti sticking ...

Page 13: ...th clamp in negative pole We will follow the electrode manufactuer s instructions in each case Equipment preparation for the working mode is drawn in the figure in this case observe that the polarity used is inverse meaning that the welding electrode holder is connected to the positive pole G F WELDING PROCESS SELECTOR C ELECTRODE MODE In this working mode you will have the functions of BARLEYING ...

Page 14: ...be kept free It must be located in a place where clean air is renewed C THE MACHINE MUST ALWAYS BE OPERATED WITH THE HOUSING ON D DO NOT DISCONNECT THE MACHINE IF IT IS HOT If you have finished the work do not disconnect the machine immediately wait until the inner cooling system has totally cooled it E KEEP THE WELDING ACCESSORIES IN GOOD CONDITIONS FOR USE F ONCE THE WELDING OPERATION HAS FINISH...

Page 15: ...luminated Equipment overheated wait until the equipment cools down Possible fault in power circuit THE ELECTRODE BURNS IN TIG WELDING Excessive welding intensity for a certain electrode Decrease welding current or change electrode for one with larger diameter Use of reverse polarity Place electrode to negative pole Lack of protection gas Regulate at an appropriate flow THE EQUIPMENT HEATS UP ABNOR...

Page 16: ...solvents as these may decompose during the welding process giving off fumes which could be very toxic This can also occur with those materials which have some kind of surface coating zinc plated galvanised etc Avoid inhaling the fumes given off in the process at all times Protect yourself from the fumes and metal dust which can be given off Use quality approved anti fume goggles Work with this equ...

Page 17: ...oudage I2max Facteur de marche 40 ºC 400 A 60 Intensité nominale de soudage X 100 I2n 40 ºC 310 A Fonction de protection de soudage VRD Fonction d aide à l amorçage HOT START RÉGLABLE Fonction de force d arc ARC FORCE RÉGLABLE Fonction d anticollage ANTISTICKING T I G Plage de régulation continu TIG I2min I2max 30 400 A Intensité maximum de soudage I2max Facteur de marche 40 ºC 400 A 60 Intensité ...

Page 18: ...a fonction de cet appareil consiste à éviter tout contact direct ou indirect avec les parties électriques sous tension L interrupteur différentiel est sélectionné en fonction de la plaque de caractéristiques INTERRUPTEUR AUTOMATIQUE IA Tripolaire L appareil sera choisi selon la plaque de caractéristiques Le branchement au secteur se fera au moyen du câble d entrée ATTENTION Vérifiez si le câble es...

Page 19: ...électeur de procédé de soudage MODE ÉLECTRODE Ce mode permet de disposer des fonctions D AIDE À L AMORÇAGE FORCE D ARC et ANTI COLLAGE Le soudage à l électrode est plus facile et plus efficace Sélecteur de procédé de soudage MODE TIG Ce mode de travail est idéal pour soudage TIG Permet l amorçage manuel par contact en établissant un faible niveau de courant au moment où l électrode touche la pièce...

Page 20: ...électrode sur le pôle positif et la prise de masse sur le négatif Dans chaque cas il faudra s en tenir aux indications réalisées par le fabricant d électrodes La préparation du poste à souder est dessinée sur la Figure pour ce mode de travail observer que dans ce cas la polarité est inverse la pince porte électrode est sur le pôle positif G F Sélecteur du procédé de soudage C MODE ÉLECTRODE Ce mod...

Page 21: ... de la machine ne doivent pas être bouchées Elle doit être placée dans un endroit bien aéré LA MACHINE DOIT TOUJOURS FONCTIONNER AVEC LA GAINE NE PAS DEBRANCHER LA MACHINE SI ELLE EST CHAUDE Si le travail a été fini ne pas débrancher immédiatement la machine attendre que le système de refroidissement intérieur la refroidisse complètement MAINTENIR LES ACCESSOIRES DE SOUDAGE EN BON ETAT UNE FOIS L ...

Page 22: ...er surchauffé Attendre que le poste à souder se refroidisse Possible panne dans le circuit de puissance L ÉLECTRODE SE BRÛLE AVEC LE SOUDAGE TIG Intensité de soudage excessive pour l une des électrodes Diminuer le courant de soudage ou changer l électrode par une de plus grand diamètre Utilisation de polarité inverse Brancher l électrode au pôle négatif Il manque du gaz de protection Régler correc...

Page 23: ...aut nettoyer la pièce de travail des éventuelles traces de graisse ou dissolvant car ces derniers peuvent se décomposer lors du procédé de soudage dégageant une fumée qui peut être très toxique Ceci peut également arriver avec le matériel qui a reçu un traitement zingage galvanisation etc Éviter à tout moment l inhalation des fumées de soudage Utiliser une protection contre la fumée et la poussièr...

Page 24: ...años o gastos imprevistos o indirectos resultantes de un uso incorrecto no serán responsabilidad de GALA GAR GB APPENDICES ELECTRICAL DRAWINGS AND REFERENCE PART LISTS DECLARATION OF CONFORMITY EC MARKING ELECTRICAL DIAGRAMS DETAIL DRAWINGS AND REFERENCE LISTS GENERAL GUARANTEE CONDITIONS GALA GAR guarantees correct operation against all manufacturing defects of the Smart 400 MMA products as from ...

Page 25: ...es de réfrigérant ou d huile Si le produit présente un défaut pendant la période de garantie GALAR GAR s engage à le réparer sans aucun frais sauf pour les dommages subis par le produit provenant d accidents mauvaise utilisation mauvais entretien accessoires inadéquats service non autorisé ou modifications de produit non réalisées par GALA GAR La décision de réparer remplacer des pièces ou fournir...

Page 26: ......

Page 27: ...ÃO 1 GALA GAR DECLARES THAT THE PRODUCT AND ACCESSORIES SUPPLIED AND REFERENCED IN THE INSTRUCTION MANUAL COMPLY WITH THE STANDARDS DESCRIBED BELOW APPLICABLE FOR 1 MARKING GALA GAR DÉCLARE QUE LE PRODUIT ET ACCESSOIRES PRÉSENTÉS ET RÉFERENCÉS DANS LE MANUEL D INSTRUCTION SONT CONFORMES AUX NORMES DÉCRITES CI DESSOUS APPLICABLES POUR LE MARQUAGE 1 GALA GAR DECLARA QUE EL PRODUCTO Y ACCESORIOS SUMI...

Page 28: ......

Page 29: ...sense board e i Byel r oboor in1 CAP ll K Ui BOO lll0 20uF 5 J07 028 3rod 007 tronoform J 45 1 11 r r r l 1ª r l r r r r r r il s 2 l g I l ij l l 8 li 1 s 1ª 1 a r I 6 l5 l413T2T1 _U4 I3TZI1 1 g e º CNB CN9 CN11 CN10 9 t I 19Y IN 19Y DriY8 1ip 1I 1 Dr i vo 1ip 1I Z M N 1 o ll IK 1 002 ffi F M j u V r Z312 21 S7 0 2 r b i n 1 M 1 FAN S K1003 I lg thernal 11ritch m fia ction owitcll PotentiOIIOter ...

Page 30: ...REPUESTOS SMART 400 MMA REF 223 00 400E 20 11 20 HR 22300400E V0 1 1 PARTS LIST SMART 400 MMA 41 41 1 ...

Page 31: ...de calor IGBT IGBT heat sink 20 222945163 Disipador de calor para el diodo Heat sink for diode 21 222900943 Placa del trasformador Current transfo board 22 222907306 Ventilador Fan 23 222907335 Protección ventilador Fan guard 24 222946831 Panel trasero Rear panel 25 222904886 Abrazadera Cable clip 26 222904925 Interruptor principal Main switch 27 222916137 Soporte del interruptor Support of switch...

Page 32: ...Gala Gar S L C Jaime Ferrán 19 50014 Zaragoza SPAIN Tel 34 976 47 34 10 Fax 34 976472450 E mail info galagar com Web www galagar com ...