GALA MIG 255 M. Technical Instructions Manual
17
Electrical installation. Electrical elements of the installation.
Sistema de protección
GALA MIG 255 M
200 V
180 V -210 V
230V
220-240 V
400V
380-415 V
460V
440-480 V
63 A 3P+T (200V) 63 A 3P+T (230V) 32 A 3P+T (400V) 16A 3P + T - 400V
Connection
plug.
Magnetothermal
switch (Curve
“D”)
DO NOT FORGET TO FIT THE EARTH CONNECTION INTO THE PLUG.
Differential
circuit breaker.
(Minimum)
3P -50 A (200V)
3P -40 A (230V)
3P 25 A (400V)
3P 20 A (460V)
Interruptor
diferencial.
(Mínimo)
3P 63A/300 mA
3P 40A/300 mA
Manguera de alimentación (RVK-1KV).
GALA MIG 255 M
Length
200- 230 V 400 - 460 V
10 m
6 mm
2
4
mm
2
15-20 m
10 mm
2
6
mm
2
When the equipment leaves the factory it is tagged with the voltage of use that has been selected internally.
Make the machine connection as shown in the Figure.
Voltage change system (In Back).
460 V
400 V
230 V
200 V
IT CONDUCTS THE OPERATION
OF CHANGE OF TENSION WITH
THE DISCONNECTED MACHINE
OF NETWORK
.