chapter 3 - page 7
During the mixing process it is possible to change the mixing time and mixing speed.
The changeable parameter
fl
ashes, to switch between the parameters push the gako button.
After the mixing process is
fi
nished the free spin program is initiated, which removes mostly
the compound from the mixing blade and the lift arm is in the removal position. The mixing unit
is automatically unlocked and can be removed from the gako unguator EMP.
With every
fi
nished mixing process, the gako unguator EMP will automatically issue an identi
fi
-
cation number. The identi
fi
cation number will help with easier documentation and exact repro-
duction of the mixing process. We recommend to record the ID number on the manufacture
protocol (chapter 5 „Identi
fi
cation Number ID“).
Aborting the mixing process
To abort the mixing process push the gako button for two seconds.
The device asks if the free spin program should be initiated.
By con
fi
rming the free spinning starts. If selected “X” the program aborts. In both cases no
ID-number is issued. To select the option push the gako button. To con
fi
rm the selection push
the gako button longer.
After pushing the gako button the start display appears to select new mixing parameters for a
following compound.
pic.: Display free spin?