WARNING THE BATHER REQUIRES THE ASSISTANCE OF A HELPER / CARER 
& SHOULD NOT ATTEMPT TO USE THIS UNIT UNAIDED 

 

WARNING!

  WHEN  USING  THIS  PRODUCT,  BASIC  PRECAUTIONS  SHOULD 

ALWAYS  BE  FOLLOWED.  READ  AND  FOLLOW  ALL  INSTRUCTIONS 
PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.  

 

DANGER

: TO REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE 

THIS PRODUCT UNLESS THEY ARE CLOSELY SUPERVISED AT ALL TIMES. 
 

WARNING!

 

USE THIS UNIT ONLY FOR ITS INTENDED PURPOSES AS DESCRIBED 

IN THIS MANUAL. 
 
USE ONLY AS INSTRUCTED BY THE MANUFACTURER. RISK OF HYPERTHERMIA 
AND POSSIBLE DROWNING.  
 
THIS PRODUCT IS TO BE FITTED WITH A THERMOSTATIC CONTROL VALVE, SET 
AT A SUITABLE BATHING TEMPERATURE 43° TO AVOID SCALDING. 

Read and follow all instructions 

    

 

DANGER

: To reduce the risk of injury, do not permit children or persons with infirmities to 

use this product unless they are closely supervised at all times. 
 

To avoid injury, exercise care when entering or exiting the Lincoln bath.  
 
Never drop or insert any objects into any openings.  
Always check the underside of the platform for any obstructions before raising the bath. 
 
Risk of electrical shock; connect only to a separate circuit protected by an RCCB 

 

WARNING!

 Risk of electric shock; do not permit electric appliances (such as a hair dryer, lamp, 

telephone, radio or television) within 1.5m of this bath.

 

 

The unit must be connected to a RCCB. Such a circuit is provided by the installer and should be tested 
on a routine basis. To test the RCCB push the test button; the RCCB should interrupt power. Push the 
RESET button; power should be restored. If the RCCB fails to operate in this manner there is a ground 
current flowing, indicating the possibility of an electrical shock. Do not use this unit. Disconnect the unit 
and have the problem corrected by a qualified service representative before any further use.  

 

Risk of electrical shock; spa motors where fitted must be connected to a RCCB protected outlet. 

 

Avoid the abuse of alcohol, drugs, or medication whilst using your Lincoln bath. 
 

 
WARNING! 

 If this unit is to be utilized by many different bathers, we would strongly recommend that it 

is cleaned regularly with a medical disinfectant. 
 
 

CLEANING INFORMATION 

 

The  Lincoln  bath  does  not  require  any  major  maintenance,  but  you  should  follow  these  simple 
instructions. 
 
To clean the bath correctly the backrest & footrest must be removed. 
 
The bath must be in the fully lowered position before lifting the platform (fig 8) 
 

Summary of Contents for LINCOLN

Page 1: ...Linc inst v2 1 1...

Page 2: ...is to provide a method of assisting with the action of entering and exiting of a bathtub for the purposes of bathing when it is difficult or impractical to do so safely through conventional means Excl...

Page 3: ...N INSTALLERS ASSUME ALL LIABILITY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORISED BY THE MANUFACTURER SHOULD BE USED WITH THIS PRODUCT SAFETY WARNING In the event of mains failure...

Page 4: ...of electrical shock connect only to a separate circuit protected by an RCCB WARNING Risk of electric shock do not permit electric appliances such as a hair dryer lamp telephone radio or television wit...

Page 5: ...its from the water or mild scratches may be removed from the bath surface with a mild cutting fluid such as T Cut or Brasso This should be applied to the affected area with a soft cloth and rubbed vig...

Page 6: ...ter Suitable for intermittent use only 2 minutes on 18 minutes off Hot water controlled by thermostatic TMV 3 valve 1 800 750 682 1 077 920 1 50 INSTALLATION INSTRUCTIONS Installation to be carried ou...

Page 7: ...e this must be accessible by the property owner to allow them to switch the unit off if required i e NOT BEHIND PANELS OR BOXED IN Test the unit is functioning by operating the up and down buttons so...

Page 8: ...ire is to be connected to every metal fitting of the installation and then fed back to the earthing system of the building If plastic pipe is used then the earth wire needs to be looped back to the co...

Page 9: ...n see fig 4 These should be firmly located into the lugs in the platform using the metal rods The rods may be adjusted slightly altering the spacing to ensure a firm fit to the platform Testing a Imme...

Page 10: ...KIT Contents M6 x 70 Coach Screws Qty 8 Fixing foot brackets to floor 6 x 30 Nylon Plugs Qty 8 Fixing foot brackets to floor WARRANTY INFORMATION This product is warranted as being free from defects d...

Page 11: ...he warranty period The warranty is limited to the value of the purchase price paid The warranty is only valid if the product has been used correctly Where there are any mechanical or electrical parts...

Page 12: ...Linc inst v2 1 12...

Page 13: ...Linc inst v2 1 13...

Page 14: ...controls to make sure the unit functions correctly Ensure the bath is free to move up and down and that all panels are securely fastened Chalk mark deposits from the water or mild scratches may be re...

Page 15: ...onthly checks the following should be carried out Visually inspect the bath all over ensuring there are no exposed wires or pipes Panels should all be fitted tightly and screws and fixings in place Lo...