background image

2X3 BAND TUBE EQUALIZER 

!

 

  if you notice smoke or an unusual odor 

  if any object or liquid gets inside the device,  

  if the device has been exposed to rain or other moisture,  

  if the device does not operate normally 

  Do  not  connect  the  appliance  to  a  mains  socket  to  which  an  electrical 

appliance  controlled  by  an  inverter,  switching  power  supply  (eg 
refrigerator, washing machine, microwave, air conditioner) or a appliance 
with a motor is connected. 

  Depending on the use of the electrical device, power supply noises may 

cause a malfunction or audible noise on this unit.If a separate electrical 
outlet cannot be used, connect a noise 

lter between this and the other 

electrical appliance. 

  The  appliance  heats  up  during  several  hours  of  continuous  operation. 

This is normal and not a cause for concern. 

  Turn o

 all devices before connecting the device to other devices. This will 

prevent damage to speakers and other equipment. 

  Use  of  the  unit  near  ampli

ers  or  other  equipment  that  contains  a 

transformer may cause noise. To resolve this issue, relocate the device or 
move it away from the interfering device. 

  Noise may be caused by using a wireless communication device near the 

device,  such  as    a  mobile  phone.  Such  noise  can  occur  when  making, 
receiving,  and  diverting  a  call.  If  you  experience  this  problem,  move  the 
wireless device away from the device or turn it o

  This unit may interfere with radio and television operation, so do not use 

near such receivers. 

  If the device is transported to a location with a very di

erent temperature 

and / or humidity, moisture may condense inside. Using the device in this 
condition  may  result  in  damage  or  malfunction.  Therefore,  wait  a  few 
hours  for  the  moisture  to  completely  evaporate  before  using  the 
appliance. 

!

 

!

2

Summary of Contents for EMPRESS GL-PEQ

Page 1: ......

Page 2: ...s unless specifically instructed to do so in this guide Pay attention to not put any solid matter flammable things coin nail etc or liquid water alcohol etc inside device Do not twist or break the power cord or place heavy objects on it Doing so may damage the cable and cause a short circuit Damaged cables can cause fire and electric shock Protect the device from intesive external shock for example f...

Page 3: ...t a cause for concern Turn off all devices before connecting the device to other devices This will prevent damage to speakers and other equipment Use of the unit near amplifiers or other equipment that contains a transformer may cause noise To resolve this issue relocate the device or move it away from the interfering device Noise may be caused by using a wireless communication device near the devic...

Page 4: ...with a soft dry or slightly damp cloth Use a soft abrasion free cloth to remove stubborn dirt Then wipe the device with a dry cloth Never use benzine thinner alcohol or other solvents strong alkaline or acidic cleaners as they may cause discoloration and deformation OVERVIEW 3 ...

Page 5: ... mains unplug the device from the mains or switch off the main switch at the IEC socket EQ IN BYPASS In BYPASS mode the device galvanically connects its outputs and inputs so we can always check the sound of the compression compared to the original signal To select the BYPASS mode set the switch to the lower position To select the EQ IN mode set the switch to the upper position TUBE BOOST By using ...

Page 6: ...o set the cut rate For complex transmission curve select the desired frequency using the FREQ Hz switch Use the LOW BOOST dB parameter to set the amount of increase Use the LOW CUT dB parameter to set the cut rate BOOST SHIFT In connection with simultaneous cutting and bosting the BOOST SHIFT function has been added to the device which is able to shift the boosted frequency proportionally to the c...

Page 7: ...2X3 BAND TUBE EQUALIZER TRANSFER CHARACTERISTICS LOW BAND 6 ...

Page 8: ... the cut rate For complex transmission curve select the desired frequency using the FREQ Hz switch Use the HIGH BOOST dB parameter to adjust the amount of increase Use the HIGH CUT dB parameter to set the cut rate CUT SHIFT In connection with simultaneous cutting and boosting the CUT SHIFT function has been added to the device which is able to shift the cutting frequency in proportion to the boost...

Page 9: ...e high frequency band is capable of bell and shelving characteristics To select the shelving mode set the switch to the upper SHELVING position To select the bell mode turn the switch to the lower BELL position TRANSFER CHARACTERISTICS HIGH BAND 8 ...

Page 10: ...s filter system there is no possibility of simultaneous cutting and lifting we are able to either cut or raise at the selected frequency on the operating surface Use the FREQ Hz rotary switch to select the desired frequency where you want to intervene To boost turn the rotary switch of the MID parameter in the direction marked BOOST until the 9 ...

Page 11: ...ired cut value is reached TRANSFER CHARACTERISTICS MID BAND GROUND LIFT The switch on the back of the device allows the outgoing audio connection to be disconnected from ground thus eliminating ground loop phenomena that occur under certain conditions To adjust the ground defrost set the GROUND LIFT switch on the rear panel to the up position 10 ...

Page 12: ...alanced XLR Maximum input level 23dBu Input impedance 10Kohm Maximum output level 23dBu Output impedance 65ohm THD N 0dBu 1Khz 0 08 THD N 20dBu 1Khz 0 8 Frequency response 20Hz 20Khz 0 2dBu Dimensions 483mmx280mmx89mm Weight 5 4 Kg Mains voltage 230V AC EU version 110V AC US version 11 ...

Page 13: ...2X3 BAND TUBE EQUALIZER EMPRESS RECALL SHEET 12 ...

Reviews: