GAI-Tronics TI984 User Manual Download Page 3

P

AGE 

2 of 14

M

ODEL 

TI984 T

ELEPHONE 

I

NTERFACE

42004-071F

f:\standard ioms - current release\42004 instr. manuals\42004-071f.doc

05/03

WARNING

This equipment generates, uses, and can radiate radio frequency energy and if not installed and
used in accordance with the instruction manual, may cause interference to radio communications.
It has been tested and found to comply with the limits for a Class “A” computing device pursuant
to Subpart J or Part 15 of the FCC Rules, which are designed to provide reasonable protection
against such interference when operated in a commercial environment.  Operation of the
equipment in a residential area is likely to cause interference.  If interference occurs, the user, at
their own expense, will be required to take whatever measures are necessary to correct this
interference.

Installation

WARNING

This device can present a 115/230 V ac shock hazard.  Please use care when handling this device.
Be sure that the ac power is not connected during wiring.

Site Requirements

The Model TI984 should be mounted near both the GAI-Tronics Page/Party

®

 system and the RJ11C

receptacle from the telephone company or Private Branch Exchange (PBX).  The distance from the TI984
to one Page/Party

®

 station should be such that someone can adjust the controls on the TI984 while

listening to the handset of the station.  The distance from the RJ11C receptacle should be less than 14
feet, to allow the use of the supplied plug-in cable.

Note

:  If there are no handset stations, contact the GAI-Tronics Field Service Department for instructions

at 800-492-1212, 8 a.m. to 4:30 p.m., Monday through Friday, Eastern Standard Time (EST).

The TI984 should be installed in an environment within the temperature range of 0º C to +70º C
(+32º F to +158º F).

Install the TI984 away from equipment that could cause excessive electrostatic, or electromagnetic
interference, or equipment that produces high voltage.

Wiring Instructions

1.

 

Remove the front cover by loosening the 4 captive screws and swinging the cover open to the left.
Disconnect the ribbon cable and the telephone cable, and pull the hinges out of the holes in the rear
enclosure.

2.

 

Determine which of the 4 available conduit locations is to be used.  Drill spots have been provided for
use with either a chassis punch or hole saw.

Summary of Contents for TI984

Page 1: ...Telephone Line Connections 4 Power 4 Page Party Connections 5 Remote Connections 5 Programming General Instructions 6 Programming Procedure 7 Entering and Exiting the Programming Mode 7 Selecting an I...

Page 2: ...n system may vary from the day shift to the night shift this interface can be configured for two independent sets of operating parameters day mode and night mode For example the method used to receive...

Page 3: ...ear both the GAI Tronics Page Party system and the RJ11C receptacle from the telephone company or Private Branch Exchange PBX The distance from the TI984 to one Page Party station should be such that...

Page 4: ...ssembly other than the recommended size it is the installer s responsibility to provide the proper earth ground bonding Hub s must be connected to the conduit before being connected to the enclosure T...

Page 5: ...mmended because it allows the use of all the available types of incoming modes If the call from the CO is to be directly connected to the Page Party system use the bypass feature available on the PBX...

Page 6: ...of the Page Party system See Figure 5 Party line connections should be made to terminals 13 and 14 as shown in Figure 5 and on the connection diagram printed on the power supply circuit board rear enc...

Page 7: ...h a set of default parameters listed in the Programming Summary Chart on page 13 Read the entire Programming section record the desired selections in the column titled User Programming and then procee...

Page 8: ...I984 party line The programmer should then proceed with the programming instructions If the access method has been changed refer to the Selecting an Incoming Access Method section page 8 for details o...

Page 9: ...nected to the party line The maximum number of seconds the call will be held before it is disconnected if not answered 0 to 99 seconds Enabling or disabling the auto connect mode If the unit is progra...

Page 10: ...bling the auto connect mode If the unit is programmed to auto connect the caller will be directly connected to the designated party line if that line is already off hook Access codes the two digit cod...

Page 11: ...after the fifth ring Hang up Delay This parameter sets the time that the TI984 pauses between the time when the Page Party station goes on hook and the call is disconnected If the delay is set to 0 th...

Page 12: ...lly transferred to the designated party line provided a station is off hook on the designated party line Function SELECT INCOMING CALL VOICE ACCESS METHOD KEY SEQUENCE 3 0 P P M M A DESCRIPTION If sel...

Page 13: ...ethod at 5 enter the following code 3 2 1 5 2 5 1 2 5 Function SET NUMBER OF INCOMING RINGS KEY SEQUENCE 4 N DESCRIPTION Sets the number of rings that must elapse before the TI984 acknowledges an inco...

Page 14: ...ne to the receiver To complete this adjustment blow into the microphone at the station while adjusting the potentiometer on the TI984 for minimum signal in the ear piece of the station As the potentio...

Page 15: ...oles Connections 4 drill spots for locating conduit entrance to internal terminal block connections 14 foot cable with USOC RJ11C type modular jack for telephone subset Dimensions 9 5 H 8 W 3 8 D inch...

Page 16: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...