Pub. 42004-783L2C
SP2 Remote Subset/Speaker Amplifier Station
Page 13 of 20
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-783L2C.docx
04/18
Settings and Adjustments
Opening the Station
Complete the following steps to open the station:
1.
Remove the four screws from the front panel and turn it to the left to expose the interior surfaces.
2.
Keep the wiring and ribbon cables connected.
3.
Mount the front panel to the back box’s left-side mounting holes using two of the screws just
removed.
Figure 10. SP2 Standard Remote Station—Interior View
Main PCBA Configuration
Refer to Figure 11 for switch, jumper, and LED locations on the Main PCBA.
Write Protect (EEPROM) Jumper
N
OTE
:
This jumper should not be changed in the field.
WDOG Enable (Watchdog) Jumper
Watchdog jumper,
P11
, enables a watchdog feature for software purposes and should not be adjusted in
the field. The default setting is installed.
Boot Enable Jumper
Jumper
P8
–
B
OOT
, is required for development purposes and should not be adjusted in the field. The
default setting for this jumper is open.