Wiring
Station Wiring
1.
Attach conduit or cable glands to the ¾-inch NPT holes on the bottom of the enclosure.
2.
Feed the low-voltage wiring conduit on the left side hole, from the front view
3.
Feed the power wiring through the right side hole, from front view.
4.
Attach the wires to the terminal blocks located on the PCBA within the enclosure (see Figure 4 for
connection points and descriptions).
5.
If using the 10438-001 Auxiliary Microphone Assembly
: Connect the assembly to the station at
terminal block
TB4-1
(
+
) and
TB4-2
(
–
), and the shield to
TB4-5
, if used.
The maximum distance from the station is 50 feet using No. 18 AWG wire.
6.
If using the 51052-003 Auxiliary Footswitch Assembly
: Connect the assembly to the station at
terminal block
TB4-8
(
+
) and
TB4-9
(
–
), and the shield to
TB4-5
, if used.
The maximum distance from the station is 50 feet using No. 18 AWG wire.
Figure 4. RigCom Station PCBA