9.  Technical Specifications 

Operational Requirements 

Systems.   

 

Public Emergency Telephone System (PETS) only. 

Not suitable for 
connection to: 

 

Public networks (PSTN) 

 

Standard PABXs 

Telephone line 
parameters 

 

On-hook current: 6mA ± 10% 

 

Ring Voltage: 30V to 100V rms, 20Hz to 50Hz 

 

Line voltage 20 to 70 Vdc 

 

Loop current 

 15mA 

Product features 

Power supply 

100% line power. 

Hookswitch 

Electronic with no external moving parts 

Time Out 

7 minutes (±1). Selectable 

Ringer loudness 

80dBA @ 1m 

Handset 

Suitable for inductive coupling to Hearing Aids having 
a `T' switch position.  

Tested to ETS 300-381 

 

Environmental limits 

Temperature: 

Operating: -20ºC to +60ºC  
Storing: -40ºC to +70ºC 

Relative Humidity  Up to 95% (non-condensing) 
Ingress 
Protection 

IP65  to EN60529:1992 – Degrees of protection provided by 
enclosures. 

Physical characteristics 

Casing material 

Die-cast Aluminium 
 

Handset Material 

Cycoloy (2800) with stainless steel cord. 

Weight 

5kg approx. 

Dimensions 

189W x 366H x 130D (mm) 

Summary of Contents for ILC-1117

Page 1: ...Doc No 502 20 0132 001 Iss2 Dec 2012 CN37277 002 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Installation and User Guide ILC 1117 Titan Illuminated Crossing Telephone GAI TRONICS...

Page 2: ...5 3 2 Handset integrity alert 5 4 Installation 6 4 1 General 6 4 2 If glands are required 6 4 3 Wall mounting 7 4 4 Pole mounting 8 5 Connections and option settings 9 6 Legend Panel 12 6 1 Legend pa...

Page 3: ...al describes the ILC 1117 model Titan telephone designed for use on PETS Public Emergency Telephone System at automatic half barrier AHB level crossings in the UK The product was introduced with the d...

Page 4: ...n Illuminated Crossing Telephone 2 2 At a Glance 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Door Handset Pushbutton Faceplate Illuminated panel Timer Switch Main Terminal Block Legend panel...

Page 5: ...for call connection timings The loop break duration is independent of how long the button is held pressed Keeping the button pressed will still only result in a 100ms break 3 1 Call timer The phone h...

Page 6: ...exposed circuit board when setting the faceplate aside during installation Caution take care to support the spring loaded door whilst open to prevent it slamming shut and trapping fingers 2 All connec...

Page 7: ...rface 4 Proceed with chosen mounting method below As standard The telephone is supplied with a pole mounting kit 100 02 0208 001 but no glands 4 3 Wall mounting 1 Using a suitable tool punch out 4 hol...

Page 8: ...late for drilling 3 Drill holes in the wall on the marked positions Select appropriate screws wall plugs etc for the type of wall bearing in mind that the weight of the complete phone is around 5kg IM...

Page 9: ...f 4 5Nm max IMPORTANT avoid the use of power tools Spinning the nuts too quickly can cause a rapid increase in heat which can cause the nuts to seize as a result of galling or cold welding Note only u...

Page 10: ...n increased risk that the telephone could be damaged by line born transients Note that user safety from the telephone network is provided by isolation and does not rely on this earth connection Do not...

Page 11: ...elephone 11 Timer Switch Main Terminal Block The timer is set by the position of switch SW2 Position the switch to the left to set the timer ON and to the right to set it OFF This unit is supplied wit...

Page 12: ...ure The legend panel is then backlit by the illuminated panel 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Variable Information Replaceable Legend Panel Fixed Information 6 1 Legend panel dim...

Page 13: ...g a tab for ease of removal It must not overlap the strip of gasket otherwise the water seal will be compromised 7 Cleaning Recommended cleaning methods are outlined below 7 1 Normal Cleaning For norm...

Page 14: ...nstallation and commissioning packages and technical support from ad hoc repairs to full maintenance contracts By choosing GAI Tronics as your aftercare provider you are ensured of manufacturer expert...

Page 15: ...e power Hookswitch Electronic with no external moving parts Time Out 7 minutes 1 Selectable Ringer loudness 80dBA 1m Handset Suitable for inductive coupling to Hearing Aids having a T switch position...

Page 16: ...rical business equipment Telephony BS6305 1992 with the exception that on hook leakage current is 6mA BS6317 1992 Lightning and transients ITU T recommendation K 21 Enhanced surge protection Recycling...

Page 17: ...ILC 1117 Titan Illuminated Crossing Telephone 17 10 CE Declaration...

Page 18: ...18 ILC 1117 Titan Illuminated Crossing Telephone...

Page 19: ...ILC 1117 Titan Illuminated Crossing Telephone 19...

Page 20: ...of Hubbell Ltd Brunel Drive Stretton Park Burton on Trent DE13 0BZ England Tel 01283 500500 Fax 01283 500400 www gai tronics co uk The policy of GAI Tronics is one of continuous improvement therefore...

Reviews: