9. Technical Specifications
Operational Requirements
Systems.
•
Public Emergency Telephone System (PETS) only.
Not suitable for
connection to:
•
Public networks (PSTN)
•
Standard PABXs
Telephone line
parameters
•
On-hook current: 6mA ± 10%
•
Ring Voltage: 30V to 100V rms, 20Hz to 50Hz
•
Line voltage 20 to 70 Vdc
•
Loop current
≥
15mA
Product features
Power supply
100% line power.
Hookswitch
Electronic with no external moving parts
Time Out
7 minutes (±1). Selectable
Ringer loudness
80dBA @ 1m
Handset
Suitable for inductive coupling to Hearing Aids having
a `T' switch position.
Tested to ETS 300-381
Environmental limits
Temperature:
Operating: -20ºC to +60ºC
Storing: -40ºC to +70ºC
Relative Humidity Up to 95% (non-condensing)
Ingress
Protection
IP65 to EN60529:1992 – Degrees of protection provided by
enclosures.
Physical characteristics
Casing material
Die-cast Aluminium
Handset Material
Cycoloy (2800) with stainless steel cord.
Weight
5kg approx.
Dimensions
189W x 366H x 130D (mm)