CommandPLUS Series Desktop Console Installation and Service Manual Console Diagnostics
31
09/07
Keyboard Diagnostics
When 1 is selected from the Service Diagnostics Menu, you are prompted to enter 1 to execute the
keyboard test or 2 to execute the LED test. Keyboard diagnostics allows the testing of all buttons and
LEDs on the front panel of the CommandPLUS Series Desktop Console. These diagnostics are useful in
servicing the unit should a problem occur. Press the
M
ODE
key at any time to exit these diagnostics.
Keyboard Test
The keyboard test is performed by pressing each button on the console except the
L
OCK
and
M
ODE
keys.
When a button is firmly pressed, a corresponding key code appears on the display. Each button press on
the console results in a different key code. Refer to Table 10 to assist you in determining the proper key
code for each button. If a key code does not appear or is different from the keycode table, service of the
front panel is necessary. Contact GAI-Tronics Technical Support.
N
OTE
:
Keyboard diagnostics can also
be tested by pressing
LOCK
+
MODE
button simultaneously during power up.
Table 10. Diagnostic Keycodes
Channel
Sel
Keycode
WC1
Keycode
WC2
Keycode
TX
Keycode
Volume
Up Code
Volume
Down Code
1 2F/10
2E/20
2D/30 2C/40 36/60 37/70
2 28/11
29/21
2A/31
2B/41 34/61 35/71
3 27/12 26/22 25/32 24/42 32/62 33/72
4 20/13 21/23 22/33 23/43 30/63 31/73
5 1F/14
1E/24
1D/34
1C/44 3E/64 3F/74
6 18/15
19/25
1A/35
1B/45 3C/65 3D/75
7 17/16 16/26 15/36 14/46 3A/66 3B/76
8 10/17 11/27 12/37 13/47 38/67 39/77
9 0F/18
0E/28
0D/38 0C/48 46/68 47/78
10 08/19 09/29 0A/39
0B/49 44/69 45/79
11 07/1A 06/2A 05/3A 04/4A 42/6A 43/7A
12 00/1B 01/2B 02/3B 03/4B 40/6B 41/7B
Option
Button
Keycode
Option
Button
Keycode
Option
Button
Keycode
Multiselect 1
71/2C
Transmit
4C/58
1
5F/01
Multiselect 2
70/2D
F1
4E/1C
2 (abc)
58/02
Phone Patch
73/2E
F2
49/1D
3 (def)
67/03
Radio Patch
72/2F
F3
4D/1E
Tel Hold
60/0C
Page 57/3C
F4 4A/1F
4
(ghi)
5E/04
Clear 50/3D
*
5C/0A
5
(jkl) 59/05
Coded 4F/3F
Multi
PL
6A/4E
Lock None
Clear
48/3E Intercom
6B/56 0
5B/00
Monitor 4B/57
LED Test
The LED test prompts you to press keys to light all or individual LEDs. Upon first entering this test, all
LEDs should be off. Pressing any key should cause all LEDs to turn on. Subsequent key presses should
light individual LEDs during this test. If console fails to operate in this manner, contact GAI-Tronics
Technical Support.