GAI-Tronics 727-001 User Manual Download Page 3

Pub. 42004-690L2C 

Model 727-001 Desk Set Access Panel 

Page 3 of 10 

f:\standard ioms - current release\42004 instr. manuals\42004-690l2c.doc 
03/13 

The data and audio connection to the system control unit is provided by an RJ-45 jack on the rear of the 
access panel as shown in Figure 2.  The following are the physical connections of the RJ-45 jack: 

Pin Connection 

1 No 

connection 

2 No 

connection 

3 No 

connection 

4 No 

connection 

 TX/RX connection 

6 + 

TX/RX 

connection 

7 No 

connection 

8 No 

connection 

 

The 5-pin XLR jack is used for connection of an optional desk mic as shown in Figure 3. 

The DB-15 connector on the rear of the access panel is used for connecting the desk set to the optional 
docking station.  This connection allows the user to connect the power and the data/audio connection to 
the rear of the docking station to ease overall installation of the docking station. 

 

Figure 2. 

 

Figure 3.  Model 727-001 Access Panel Typical Connections (Rear View) 

Summary of Contents for 727-001

Page 1: ...tem that can be used for public address intercommunication and emergency notification How to Use the Assembly Application The Model 727 001 Desk Set Access Panel is used to communicate initiate alarms...

Page 2: ...terfaces A 3 conductor ac power cord is included with the access panel One end of the power cord is connected to the 3 prong connector located on the back of the power supply while the other end is pl...

Page 3: ...2 No connection 3 No connection 4 No connection 5 TX RX connection 6 TX RX connection 7 No connection 8 No connection The 5 pin XLR jack is used for connection of an optional desk mic as shown in Fig...

Page 4: ...a cable from the RJ 45 jack on the rear of the unit to the API connecting block located in the ADVANCE control cabinet If the 7 foot cable is not long enough use a twisted pair cable terminated on one...

Page 5: ...up to center the printed text within the perforated strips To modify the text size and color of the text in the blocks you will need to unprotect the document as outlined below If you need to modify t...

Page 6: ...bel and pull it out from behind 2 Slide label out using the tab that has been exposed Button Layout and Default Configurations For units to be used without a docking station all buttons and 24 LEDs ar...

Page 7: ...ition to other configurable features The standard features include a handset used for page and party functions and an integral speaker to monitor page audio Handset Communications The handset is used...

Page 8: ...the desktop power supply Call for service of the access panel LEDs are blinking and the sounder is beeping Verify that the data cable is properly connected between the access panel and the control uni...

Page 9: ...V ac maximum Environmental Operating temperature range 32 F to 120 F 0 C to 49 C Relative humidity Non condensing 85 max Mechanical Unit dimensions 7 60 W 8 93 L 4 63 D inches 193 0 226 9 117 6 mm Uni...

Page 10: ...Docking Station with VFD 13610 002 Desk top Access Panel Desk Mic Replacement Parts Model Number Description 14919 113 Keypad Replacement Slide In Labels set of 4 51035 013 Replacement 28 Button Keypa...

Page 11: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...