GAI-Tronics 370-901 Manual Download Page 9

Pub. 42004-525A 

Model 370-901 SP2 to Page/Party

®

 Bridge 

Page 7 of 16 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-525A.docx 
08/18 

Mute Connection—P5 

The muting conductor of the Page/Party

®

 system cable has no function in the SP2 to Page/Party

®

 Bridge.  

Terminal block 

P5

 provides a dead ended termination for the muting conductor of the Page/Party

®

 system 

cable (see Figure 4)

1.

 

Install a ferrule onto the end of the orange wire. 

2.

 

Connect the wire to pin one on pluggable terminal block 

P5

3.

 

Connect the pluggable terminal block to terminal block 

P5

Power—P1 

The SP2/Page/Party

®

 Bridge operates from a 120/230 V 

ac, 50/60 Hz power source.  AC power is connected at 
terminal block 

P1

1.

 

Pull the cable from the power source into the 
enclosure. 

2.

 

Install ferrules onto the wire ends. 

3.

 

Connect the line, and neutral, conductors to the 
pluggable terminal block (see Figure 4 and Table 6). 

4.

 

Connect the pluggable terminal block to terminal 
block 

P1

 

Close the Enclosure 

1.

 

Reconnect the front cover to the rear enclosure by pushing the hinge pins on the front cover into the 
holes on the left side of the rear enclosure until a click is heard. 

2.

 

Rotate the front cover to close the enclosure. 

3.

 

Install and tighten the four screws on the front cover. 

Configuration 

SP2 to Page/Party

®

 Bridges are configured using the GUDA (GAI-TRONICS Universal Device 

Application) software.  Install the GUDA software and run it to configure Page/Party

®

 bridges as follows: 

1.

 

Launch the GUDA application by double clicking the GAI-TRONICS Universal Device Application 
shortcut from the start menu. 

 

2.

 

Choose the network interface to perform the discovery. 

 

Table 6.  AC Power—P1 

Pin 

Label 

Description 

P1-1 

LINE 

ac hot 

P1-2 

 

no connection 

P1-3 

NEUTRAL 

neutral 

 

Summary of Contents for 370-901

Page 1: ...losure 2 Mount the Enclosure 3 Field Terminations 3 Earth Ground 3 Ethernet TB1 4 Page Party 33 Ohm Audio Connections P2 5 60029 Series Page Party System Cable 5 Channel Isolation Inputs P3 6 Contact...

Page 2: ...A 19605 USA 610 777 1374 800 492 1212 Fax 610 796 5954 VISIT WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS GUDA Software Updates 15 Troubleshooting 15 Service and Spare Parts 16 Specification...

Page 3: ...n may only be used in connection with the operation of your GAI TRONICS product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party Gen...

Page 4: ...Adhere to all warnings on the unit and in the operating instructions Attachments Attachments not recommended by the product manufacturer should not be used as they may cause hazards Open the Enclosure...

Page 5: ...unting holes are 0 280 inches in diameter 4 Install conduit using Myers ST 4 1 25 inch Scru Tite hubs or equivalent Reducers must be used for smaller conduit sizes to ensure proper contact with the su...

Page 6: ...Install ferrules onto the wire ends 3 Connect the Ethernet cable to the 8 position pluggable terminal block TB1 see Figure 4 and Table 1 4 Connect the pluggable terminal block to terminal block recept...

Page 7: ...y SystemCable Page Party stations should be connected using GAI TRONICS 60029 Series system cable Refer to Table 3 for the Page Party system cable color codes Table 3 Page Party 60029 Series System Ca...

Page 8: ...re terminated at terminal block P4 P4 is an 18 position terminal block Three position pluggable terminal blocks are used for each output to simplify the connection of the outputs 1 Pull the cable s fo...

Page 9: ...es onto the wire ends 3 Connect the line and neutral conductors to the pluggable terminal block see Figure 4 and Table 6 4 Connect the pluggable terminal block to terminal block P1 Close the Enclosure...

Page 10: ...m the GUDA screen 4 Double click the SP2 TO PAGE PARTY BRIDGE to configure from the list of devices displayed Bridges that are not configured appear as follows 5 Enter the default user name shown and...

Page 11: ...emory address of the control service IP Address client network address leave blank for DHCP clients Netmask subnet mask leave blank for DHCP clients Default Gateway IP address of router to other netwo...

Page 12: ...Multicast Port multicast service port address for the audio channel Multicast TTL time to live for multicast network traffic Analog VOX Threshold mV signal voltage where the VOX circuit picks up 1 10...

Page 13: ...TATUS screen provides the following information Firmware Version bridge firmware version IP Address IP address currently assigned to the bridge MAC Address MAC address of the bridge Network Data Rate...

Page 14: ...streams passing through the bridge Operation The SP2 to Page Party Bridge provides real time audio communication between SP2 and Page Party systems No user interaction is required after the bridge is...

Page 15: ...s are not disconnected with a pause in conversation Table 7 System Status LEDs LED State Description PL1 On activity on party line one PL2 On activity on party line two PL3 On activity on party line t...

Page 16: ...tandard Windows OPEN dialog box Browse to the desired folder and open the desired firmware file and then click BEGIN UPDATE in the DEVICE FIRMWARE UPDATE box to update the devices firmware Enable Disa...

Page 17: ...guration to take effect GUDA Software Updates Click OK to install updates to the GUDA software when the UPDATE AVAILABLE box appears after launching the GUDA application Updates are made available for...

Page 18: ...50 60 Hz Ethernet 100Base TX 1000Base T with IGMP Output relay contact rating 1 A 30 V dc Channel isolation inputs dry contact Ethernet Cable Category 5 or better Speed 100 Mbps minimum Maximum stati...

Page 19: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: